Ruomeng Chen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Ruomeng Chen has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Yaxiong Liu
School of Mechatronic Engineering and Automation, Foshan University, Foshan, 528000, China; Ji Hua Laboratory, Foshan, 528200, China
2 shared publications Ao Fang
Zhejiang University
1 shared publication- Bo Wang
Departments of Pharmacology, School of Basic Medical Sciences, Xi'an Jiaotong University Health Science Center, Xi'an, China
1 shared publication - Dichen Li
School of Mechanical Engineering, Xi'an Jiaotong University
1 shared publication Guangbin Zhao
Xi'an Jiaotong University
1 shared publication- Jian Qiao
School of Mechatronic Engineering and Automation, Foshan University, No. 33 Guangyun Road, Nanhai District, Foshan 528231, China
1 shared publication
Latest Publications
- Open Access
- 22 August 2023
- Published by Springer Nature in Research Square
Study on the critical force range of magnetic compression anastomosis in rabbit intestinal tissue
Purpose Magnetic compression anastomosis is a new type of anastomosis that can replace traditional manual suture in the reconstruction of digestive tract anastomosis. One of the important prerequisites for the precise mechanical design of the magnamosis device is to obtain the critical compressive stress for ischemic necrosis of the lumen tissue. Although it is difficult to directly observe the deformation and closure of blood vessels in intestinal tissue under magnetic compression, the external manifestation is tissue necrosis. Therefore, the relationship between vascular deformation and crushing stress can be established by studying the necrosis degree of intestinal tissue under stress. Methods Magnets with different magnetic force groups (0.3、0.4、0.6、0.7、1.0 and 1.2N ) were implanted into each rabbit to form intestinal tissue side-to-side anastomoses. Three experimental press areas were placed for each rabbit. Thirty-six rabbits were euthanized on each of postoperative day 3, day 5 and day 7. Anastomoses were then harvested and compared with respect to direct observation and histology. Results By analyzing the healing state of the tissue in the anastomosis area and the necrosis of the tissue in the anastomotic area, the 0.3N tissue was basically not necrotic, and the 0.4N tissue began to become necrotic, and there was almost no difference between the two specimens at 7 days, and both showed slight healing. Therefore, 0.3N-0.4N is determined as the optimal compressive force range. According to the bottom surface of the magnet device, and the corresponding critical compressive range was 0.88×10− 2 − 1.17×10− 2MPa. Conclusions Through magnetic compression anastomosis experiment of intestinal tissue in rabbits, the critical compressive stress range of intestinal tissue was obtained was 0.88×10− 2 − 1.17×10− 2MPa.
- 22 August 2023
- Published by Springer Nature in Research Square
Open AccessStudy on the critical force range of magnetic compression anastomosis in rabbit intestinal tissue
Purpose Magnetic compression anastomosis is a new type of anastomosis that can replace traditional manual suture in the reconstruction of digestive tract anastomosis. One of the important prerequisites for the precise mechanical design of the magnamosis device is to obtain the critical compressive stress for ischemic necrosis of the lumen tissue. Although it is difficult to directly observe the deformation and closure of blood vessels in intestinal tissue under magnetic compression, the external manifestation is tissue necrosis. Therefore, the relationship between vascular deformation and crushing stress can be established by studying the necrosis degree of intestinal tissue under stress. Methods Magnets with different magnetic force groups (0.3、0.4、0.6、0.7、1.0 and 1.2N ) were implanted into each rabbit to form intestinal tissue side-to-side anastomoses. Three experimental press areas were placed for each rabbit. Thirty-six rabbits were euthanized on each of postoperative day 3, day 5 and day 7. Anastomoses were then harvested and compared with respect to direct observation and histology. Results By analyzing the healing state of the tissue in the anastomosis area and the necrosis of the tissue in the anastomotic area, the 0.3N tissue was basically not necrotic, and the 0.4N tissue began to become necrotic, and there was almost no difference between the two specimens at 7 days, and both showed slight healing. Therefore, 0.3N-0.4N is determined as the optimal compressive force range. According to the bottom surface of the magnet device, and the corresponding critical compressive range was 0.88×10− 2 − 1.17×10− 2MPa. Conclusions Through magnetic compression anastomosis experiment of intestinal tissue in rabbits, the critical compressive stress range of intestinal tissue was obtained was 0.88×10− 2 − 1.17×10− 2MPa.
- Open Access
Development of Strong and Tough β-TCP/PCL Composite Scaffolds with Interconnected Porosity by Digital Light Processing and Partial Infiltration
Strong and tough β-TCP/PCL composite scaffolds with interconnected porosity were developed by combining digital light processing and vacuum infiltration. The composite scaffolds were comprised of pure β-TCP, β-TCP matrix composite and PCL matrix composite. The porous β-TCP/PCL composite scaffolds showed remarkable mechanical advantages compared with ceramic scaffolds with the same macroscopic pore structure (dense scaffolds). The composite scaffolds exhibited a significant increase in strain energy density and fracture energy density, though with similar compressive and flexural strengths. Moreover, the composite scaffolds had a much higher Weibull modulus and longer fatigue life than the dense scaffolds. It was revealed that the composite scaffolds with interconnected porosity possess comprehensive mechanical properties (high strength, excellent toughness, significant reliability and fatigue resistance), which suggests that they could replace the pure ceramic scaffolds for degradable bone substitutes, especially in complex stress environments.
Open AccessDevelopment of Strong and Tough β-TCP/PCL Composite Scaffolds with Interconnected Porosity by Digital Light Processing and Partial Infiltration
Strong and tough β-TCP/PCL composite scaffolds with interconnected porosity were developed by combining digital light processing and vacuum infiltration. The composite scaffolds were comprised of pure β-TCP, β-TCP matrix composite and PCL matrix composite. The porous β-TCP/PCL composite scaffolds showed remarkable mechanical advantages compared with ceramic scaffolds with the same macroscopic pore structure (dense scaffolds). The composite scaffolds exhibited a significant increase in strain energy density and fracture energy density, though with similar compressive and flexural strengths. Moreover, the composite scaffolds had a much higher Weibull modulus and longer fatigue life than the dense scaffolds. It was revealed that the composite scaffolds with interconnected porosity possess comprehensive mechanical properties (high strength, excellent toughness, significant reliability and fatigue resistance), which suggests that they could replace the pure ceramic scaffolds for degradable bone substitutes, especially in complex stress environments.
- Open Access
- 7 August 2019
- Published by Springer Nature in BioMedical Engineering OnLine
- Vol. 18 (1) , 1-13
Gelatin-based perfusable, endothelial carotid artery model for the study of atherosclerosis
Carotid artery geometry is important for recapitulating a pathophysiological microenvironment to study wall shear stress (WSS)-induced endothelial dysfunction in atherosclerosis. Endothelial cells (ECs) cultured with hydrogel have been shown to exhibit in vivo-like behaviours. However, to date, studies using hydrogel culture have not fully recapitulated the 3D geometry and blood flow patterns of real-life healthy or diseased carotid arteries. In this study, we developed a gelatin-patterned, endothelialized carotid artery model to study the endothelium response to WSS. Two representative regions were selected based on the computational fluid dynamics on the TF-shaped carotid artery: Region ECA (external carotid artery) and Region CS (carotid sinus). Progressive elongation and alignment of the ECs in the flow direction were observed in Region ECA after 8, 16 and 24 h. However, the F-actin cytoskeleton remained disorganized in Region CS after 24 h. Further investigation revealed that expression of vascular cell adhesion molecule-1 (VCAM-1) and intercellular adhesion molecule-1 (ICAM-1) was greatly increased in Region CS relative to that in Region ECA. The physiological WSS in the carotid artery system was found to stimulate nitric oxide (NO) and prostacyclin (PGI2) release and inhibit endothelin-1 (ET-1) release after 24-h perfusion experiments. The effective permeability (E.P) of fluorescein isothiocyanate (FITC)–dextran 40 kDa in Regions ECA and CS was monitored, and it was found that the turbulence WSS value (in Region CS) was less than 0.4 Pa, and there was a significant increase in the E.P relative to that in Region ECA, in which laminar WSS value was 1.56 Pa. The tight junction protein (ZO-1) production was shown that the low WSS in Region CS induced ZO-1-level downregulation compared with that in Region ECA. The results suggested that the gelatin-based perfusable, endothelial carotid artery model can be effective for studying the pathogenesis of atherosclerosis by which flow dynamics control the endothelium layer function in vitro.
- 7 August 2019
- Published by Springer Nature in BioMedical Engineering OnLine
- Vol. 18 (1) , 1-13
Open AccessGelatin-based perfusable, endothelial carotid artery model for the study of atherosclerosis
Carotid artery geometry is important for recapitulating a pathophysiological microenvironment to study wall shear stress (WSS)-induced endothelial dysfunction in atherosclerosis. Endothelial cells (ECs) cultured with hydrogel have been shown to exhibit in vivo-like behaviours. However, to date, studies using hydrogel culture have not fully recapitulated the 3D geometry and blood flow patterns of real-life healthy or diseased carotid arteries. In this study, we developed a gelatin-patterned, endothelialized carotid artery model to study the endothelium response to WSS. Two representative regions were selected based on the computational fluid dynamics on the TF-shaped carotid artery: Region ECA (external carotid artery) and Region CS (carotid sinus). Progressive elongation and alignment of the ECs in the flow direction were observed in Region ECA after 8, 16 and 24 h. However, the F-actin cytoskeleton remained disorganized in Region CS after 24 h. Further investigation revealed that expression of vascular cell adhesion molecule-1 (VCAM-1) and intercellular adhesion molecule-1 (ICAM-1) was greatly increased in Region CS relative to that in Region ECA. The physiological WSS in the carotid artery system was found to stimulate nitric oxide (NO) and prostacyclin (PGI2) release and inhibit endothelin-1 (ET-1) release after 24-h perfusion experiments. The effective permeability (E.P) of fluorescein isothiocyanate (FITC)–dextran 40 kDa in Regions ECA and CS was monitored, and it was found that the turbulence WSS value (in Region CS) was less than 0.4 Pa, and there was a significant increase in the E.P relative to that in Region ECA, in which laminar WSS value was 1.56 Pa. The tight junction protein (ZO-1) production was shown that the low WSS in Region CS induced ZO-1-level downregulation compared with that in Region ECA. The results suggested that the gelatin-based perfusable, endothelial carotid artery model can be effective for studying the pathogenesis of atherosclerosis by which flow dynamics control the endothelium layer function in vitro.