Impact of Acute Changes of Left Ventricular Contractility on the Transvalvular Impedance: Validation Study by Pressure-Volume Loop Analysis in Healthy Pigs
Open Access
- 19 November 2013
- journal article
- research article
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 8 (11) , e80591
Abstract
The real-time and continuous assessment of left ventricular (LV) myocardial contractility through an implanted device is a clinically relevant goal. Transvalvular impedance (TVI) is an impedentiometric signal detected in the right cardiac chambers that changes during stroke volume fluctuations in patients. However, the relationship between TVI signals and LV contractility has not been proven. We investigated whether TVI signals predict changes of LV inotropic state during clinically relevant loading and inotropic conditions in swine normal heart. The assessment of RVTVI signals was performed in anesthetized adult healthy anesthetized pigs (n = 6) instrumented for measurement of aortic and LV pressure, dP/dtmax and LV volumes. Myocardial contractility was assessed with the slope (Ees) of the LV end systolic pressure-volume relationship. Effective arterial elastance (Ea) and stroke work (SW) were determined from the LV pressure-volume loops. Pigs were studied at rest (baseline), after transient mechanical preload reduction and afterload increase, after 10-min of low dose dobutamine infusion (LDDS, 10 ug/kg/min, i.v), and esmolol administration (ESMO, bolus of 500 µg and continuous infusion of 100 µg·kg−1·min−1). We detected a significant relationship between ESTVI and dP/dtmax during LDDS and ESMO administration. In addition, the fluctuations of ESTVI were significantly related to changes of the Ees during afterload increase, LDDS and ESMO infusion. ESTVI signal detected in right cardiac chamber is significantly affected by acute changes in cardiac mechanical activity and is able to predict acute changes of LV inotropic state in normal heart.Keywords
This publication has 43 references indexed in Scilit:
- A randomized pilot study of optimization of cardiac resynchronization therapy in sinus rhythm patients using a peak endocardial acceleration sensor vs. standard methodsEP Europace, 2012
- Usefulness of Low-Dose Dobutamine Echocardiography to Predict Response and Outcome in Patients Undergoing Cardiac Resynchronization TherapyThe American Journal of Cardiology, 2011
- Relationship between intracardiac impedance and left ventricular contractility in patients undergoing cardiac resynchronization therapyEP Europace, 2011
- Myocardial microvascular permeability, interstitial oedema, and compromised cardiac functionCardiovascular Research, 2010
- Left ventricular mechanical activity detected by impedance recordingEP Europace, 2010
- Multiple Vector Impedance Measurements During Biventricular Pacing: Feasibility and Possible Implications for Hemodynamic MonitoringPacing and Clinical Electrophysiology, 2009
- Pressure-volume loop analysis during implantation of biventricular pacemaker/cardiac resynchronization therapy device to optimize right and left ventricular pacing sitesEuropean Heart Journal, 2008
- Reduced Left Ventricular Compliance and Mechanical Efficiency after Prolonged Inhibition of NO Synthesis in Conscious DogsThe Journal of Physiology, 2003
- Autonomic Nervous System Controlled Closed Loop Cardiac PacingPacing and Clinical Electrophysiology, 1992
- Automatic Adjustment of Pacing Parameters Based on Intracardiac Impedance MeasurementsPacing and Clinical Electrophysiology, 1990