A Glycemic Status Classification Model Using a Radiofrequency Noninvasive Blood Glucose Monitor
Open Access
- 13 December 2024
- journal article
- research article
- Published by SAGE Publications in Diabetes Technology & Therapeutics
- Vol. 26 (12) , 979-983
Abstract
Despite significant efforts in the development of noninvasive blood glucose (BG) monitoring solutions, delivering an accurate, real-time BG measurement remains challenging. We sought to address this by using a novel radiofrequency (RF) glucose sensor to noninvasively classify glycemic status. The study included 31 participants aged 18–65 with prediabetes or type 2 diabetes and no other significant medical history. During control sessions and oral glucose tolerance test sessions, data were collected from both a RF sensor that rapidly scans thousands of frequencies and concurrently from a venous blood draw measured with an US Food and Drug Administration (FDA)-cleared glucose hospital meter system to create paired observations. We trained a time series forest machine learning model on 80% of the paired observations and reported results from applying the model to the remaining 20%. Our findings show that the model correctly classified glycemic status 93.37% of the time as high, normal, or low.Keywords
This publication has 25 references indexed in Scilit:
- 130-LB: GWave—A Novel Noninvasive Glucose Blood Monitoring Radio Wave–Based TechnologyDiabetes, 2023
- Continuous Glucose Monitoring: Review of an Innovation in Diabetes ManagementThe American Journal of the Medical Sciences, 2019
- Permittivity extraction of glucose solutions through artificial neural networks and non-invasive microwave glucose sensingSensors and Actuators A: Physical, 2018
- Random Forest Based Ensemble Classifiers for Predicting Healthcare-Associated Infections in Intensive Care Units2016
- Ultrahigh-Sensitivity Mediator-Free Biosensor Based on a Microfabricated Microwave Resonator for the Detection of Micromolar Glucose ConcentrationsIEEE Transactions on Microwave Theory and Techniques, 2015
- A random forest classifier for lymph diseasesComputer Methods and Programs in Biomedicine, 2014
- Point‐of‐care glucose monitoring on the neonatal unitJournal of Paediatrics and Child Health, 2011
- Noninvasive and Minimally Invasive Methods for Transdermal Glucose MonitoringDiabetes Technology & Therapeutics, 2005
- Non-Invasive Glucose Measurement Technologies: An Update from 1999 to the Dawn of the New MillenniumDiabetes Technology & Therapeutics, 2004
- Non-Invasive Glucose Monitoring by NAD(P)H Autofluorescence Spectroscopy in Fibroblasts and Adipocytes: A Model for Skin Glucose SensingDiabetes Technology & Therapeutics, 2003