Comparison of the accuracy of 11 intraocular lens power calculation formulas
- 15 October 2020
- journal article
- research article
- Published by SAGE Publications in European Journal of Ophthalmology
- Vol. 31 (5) , 2370-2376
Abstract
Purpose: To compare the accuracy of 11 intraocular lens (IOL) power calculation formulas (SRK-T, Hoffer Q, Holladay I, Haigis, Holladay II, Olsen, Barrett Universal II, Hill-RBF, Ladas Super formula, EVO and Kane). Setting: Private university hospital (QuironSalud, Madrid, Spain). Design: Retrospective case series Methods: Data were compiled from 481 eyes of 481 patients who had undergone uneventful cataract surgery with IOL insertion. Preoperative biometric measurements were made using an IOL Master® 700. Respective ULIB IOL constants ( http://ocusoft.de/ulib/c1.htm ) for each of 4 IOL models implanted were used to calculate the predictive refractive outcome for each formula. This was compared with the actual refractive outcome determined 3 months postoperatively. The primary outcome was mean absolute prediction error (MAE). The study sample was divided according to axial length (AL) into three groups of eyes: short (⩽22.00 mm), normal (22.00–25.00 mm) and long (⩾25.00 mm). Results: The Barrett Universal II and Haigis formulas yielded the lowest MAEs over the entire AL range ( p < .01, except EVO) as well as in the long ( p < .01, all formulas) and normal ( p < .01, except Haigis, Holladay II, Olsen and LSF) eyes. In the short eyes, the lower MAEs were provided by Haigis and EVO ( p < .01 except Hoffer Q, SRK/T and Holladay I). Conclusions: Barrett Universal II was the most accurate for IOL power calculation in the normal and long eyes. For short eyes, the formulas Haigis and EVO seem best at predicting refractive outcomes.Keywords
This publication has 16 references indexed in Scilit:
- Meta‐analysis of accuracy of intraocular lens power calculation formulas in short eyesClinical & Experimental Ophthalmology, 2017
- Accuracy of 3 new methods for intraocular lens power selectionJournal of Cataract & Refractive Surgery, 2017
- Intraocular lens power formula accuracy: Comparison of 7 formulasJournal of Cataract & Refractive Surgery, 2016
- Comparison of 9 intraocular lens power calculation formulasJournal of Cataract & Refractive Surgery, 2016
- Protocols for Studies of Intraocular Lens Formula AccuracyAmerican Journal of Ophthalmology, 2015
- Intraocular lens power calculation for eyes with an axial length greater than 26.0 mm: Comparison of formulas and methodsJournal of Cataract & Refractive Surgery, 2015
- The Effect of Testing Distance on Intraocular Lens Power CalculationJournal of Refractive Surgery, 2014
- Ophthalmic statistics note 1: unit of analysisBritish Journal of Ophthalmology, 2013
- Statistical guidelines for the analysis of data obtained from one or both eyesOphthalmic and Physiological Optics, 2012
- Development of the SRK/T intraocular lens implant power calculation formulaJournal of Cataract & Refractive Surgery, 1990