Resistance to Surfactant and Protein Fouling Effects at Conducting Diamond Electrodes
- 30 November 2004
- journal article
- research article
- Published by Wiley in Electroanalysis
- Vol. 17 (4) , 305-311
Abstract
Boron‐doped diamond thin‐film electrodes display negligible fouling effects in the presence of high levels of surface‐active materials, including proteins. Dramatic improvements in the stability of the analyte response (compared to common glassy carbon and carbon paste electrodes) are illustrated using bovine serum albumin (BSA), gelatin, and Triton X‐100 in connection with repetitive square‐wave voltammetric (SWV) measurements. The voltammetric response of ascorbic acid at the diamond electrode exhibits negligible shifts in peak potentials and minimal depressions of current signals over a wide range of surfactant concentrations (0–750 ppm). For example, the diamond electrode exhibited 70, 50 and 60 mV potential shifts for 10 repetitive voltammetric scans in the presence of 100 ppm BSA, gelatin and Triton X‐100, respectively, compared to 120, 190, and 280 mV shifts observed at the glassy carbon electrode. Furthermore, only 4.3 and 6.2% of the initial current decays were observed in the presence of 100 ppm Triton X‐100 and gelatin, respectively (compared to 45.2 and 34.4% diminutions at the glassy carbon electrode). Such improved performance was also confirmed from the SWV measurements of uric acid, dihydroxyphenylacetic acid, and catechol. The greatly improved resistance to surfactant interference reflects the fact that the as‐grown diamond thin film, composed of oxide‐free and hydrogen‐terminated surface, has a relatively lower surface energy and minimal electrostatic attributes, either specific or general, so that little adsorption of surface‐active agents occurs. The topographic AFM images of the diamond electrode surface confirm a negligible BSA fouling effect after repetitive SWV measurements. Such enhanced antifouling features make diamond electrodes very attractive for numerous real‐life electroanalytical applications.Keywords
This publication has 33 references indexed in Scilit:
- Effect of Surface-Active Compounds on the Stripping Voltammetric Response of Bismuth Film ElectrodesElectroanalysis, 2001
- Analytical Electochemistry2000
- Anodization of Glassy Carbon Electrodes in Oligomers of Ethylene Glycol and Their Monomethyl Ethers as a Tool for the Elimination of Protein AdsorptionAnalytical Sciences, 1997
- Antifouling Membrane-Covered Voltammetric Microsensor for in Situ Measurements in Natural WatersAnalytical Chemistry, 1996
- Adsorption of proteins onto surfaces containing end-attached oligo(ethylene oxide): a model system using self-assembled monolayersJournal of the American Chemical Society, 1993
- Tissue bioelectrode for eliminating protein interferencesAnalytical Chemistry, 1991
- Permselectivity and ion-exchange properties of Eastman-AQ polymers on glassy carbon electrodesAnalytical Chemistry, 1989
- Application of polymer-coated glassy carbon electrodes in anodic stripping voltammetryAnalytical Chemistry, 1987
- Cellulose acetate coated mercury film electrodes for anodic stripping voltammetryAnalytical Chemistry, 1986
- Surface-modified electrochemical detector for liquid chromatographyAnalytical Chemistry, 1983