Aortic valve area index values of Trifecta implants correlate with energy loss and increased valve stress
Authors:
- 25 June 2024
- journal article
- research article
- Published by Springer Nature in Journal of Artificial Organs
- Vol. 28 (1) , 61-68
Abstract
Biological valves are becoming more frequently used in aortic valve replacement. While several reports have evaluated the performance of biological valves, echocardiography studies during exercise stress remain scarce. Furthermore, no current reports compare rate changes in the aortic valve area of biological valves under increased exercise load. Here, we performed exercise stress echocardiography in patients after AVR with Trifecta or Inspiris valves and compared the rates of change in aortic valve areas (AVA). In addition, hydrodynamic analysis at rest was conducted with four-dimensional flow magnetic resonance imaging (4D-flow MRI). Exercise stress echocardiography was performed in seven Trifecta and seven Inspiris patients who underwent AVR at our hospital while 4D flow MRI was performed in all but two Trifecta cases. Comparing the percentage change in AVA when loaded to 25 W versus at rest, Trifecta was greater than Inspiris (28.7 ± 36.0 vs − 0.8 ± 12.4%). The smaller AVA at rest was considered causative for this. Meanwhile, Trifecta systolic energy loss in the prosthetic valve segment on 4D-flow MRI (97.5 ± 35.9 vs 52.7 ± 25.3 mW) was higher than Inspiris. The opening of the Trifecta valve was considered to be restricted at rest and this may reflect the current reports of early valve degradation requiring reoperation. Taken together, we observed that the Trifecta design may promote faster wear due to higher valve stress.Keywords
This publication has 23 references indexed in Scilit:
- Durability and Performance of 2298 Trifecta Aortic Valve Prostheses: A Propensity-Matched AnalysisThe Annals of Thoracic Surgery, 2021
- Early Structural Valve Degeneration of Trifecta BioprosthesisThe Annals of Thoracic Surgery, 2020
- Early First-Generation Trifecta Valve Failure: A Case Series and a Review of the LiteratureThe Annals of Thoracic Surgery, 2020
- Current status of cardiovascular surgery in Japan, 2013 and 2014: A report based on the Japan Cardiovascular Surgery Database. 4. Valvular heart surgeryGeneral Thoracic and Cardiovascular Surgery, 2017
- Four-dimensional flow MRI of stented versus stentless aortic valve bioprosthesesEuropean Radiology, 2017
- Midterm Durability and Hemodynamic Performance of a Third-Generation Bovine Pericardial Prosthetic Aortic Valve: The Leipzig ExperienceThe Annals of Thoracic Surgery, 2017
- Mid-term durability of the Trifecta bioprosthesis for aortic valve replacementThe Journal of Thoracic and Cardiovascular Surgery, 2017
- Early hemodynamic performance of the third generation St Jude Trifecta aortic prosthesis: A systematic review and meta-analysisThe Journal of Thoracic and Cardiovascular Surgery, 2015
- National trends in utilization and in-hospital outcomes of mechanical versus bioprosthetic aortic valve replacementsThe Journal of Thoracic and Cardiovascular Surgery, 2015
- The St Jude Medical Trifecta aortic pericardial valve: Results from a global, multicenter, prospective clinical studyThe Journal of Thoracic and Cardiovascular Surgery, 2014