Yasuyuki Suzuki
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Yasuyuki Suzuki has a total of 49 co-authors. Here are the top co-authors by number of shared publications:
- Bryan James Mathis
Department of Cardiovascular Surgery, University of Tsukuba, Tsukuba, Japan
5 shared publications Yuji Hiramatsu
Department of Cardiovascular Surgery Institute of Medicine, University of Tsukuba Tsukuba Ibaraki Japan
5 shared publicationsBryan J. Mathis
Department of Cardiovascular Surgery, Institute of Medicine, University of Tsukuba, Tsukuba, Japan
3 shared publications- Hideyuki Kato
Department of Cardiovascular Surgery, University of Tsukuba, Tsukuba, Japan
3 shared publications Hiroaki Sakamoto
Department of Cardiovascular Surgery, University of Tsukuba Institute of Medicine, Tsukuba, Japan
3 shared publications- Muneaki Matsubara
Department of Congenital and Pediatric Heart Surgery, TUM University Hospital, German Heart Centre, Munich, Germany
3 shared publications
Latest Publications
- Open Access
- 14 August 2026
- Published by Wolters Kluwer Health in Annals of Medicine & Surgery
- Vol. 88 (9) , 5620-5625
Evaluating the efficacy of recombinant factor VIIa for non-surgical persistent bleeding in cardiovascular surgery: a retrospective cohort study
Background: Persistent bleeding after cardiovascular surgery challenges hemostatic management, especially in pediatric patients, but recombinant activated factor VIIa (rFVIIa), when used as a procoagulant, may improve patient outcomes. Materials and methods: We retrospectively evaluated 34 cardiac surgery patients who received recombinant rFVIIa for nonsurgical bleeding. Data on patient characteristics, surgical technique, rFVIIa administration, blood product use, complications, and hemostatic evaluation were collected. Red blood cell (RBC) transfusion volumes for 1 hour before and after rFVIIa administration were compared via a paired t -test. Results: Nineteen adult patients (mean age, 56.3 ± 15.3 years) and 15 pediatric patients [neonates (birth to 28 days), 7/15; infants (29 days to 1 year), 7/15; and preschoolers (3–6 years), 1/15] were included. RBC transfusion volumes were significantly reduced in adults (mean difference, 192.6 mL; 95% CI, 128.8–256.4 mL; P value < 0.001) and pediatric patients (mean difference, 37.0 mL/kg; 95% CI, 29.3–44.6 mL/kg; P value < 0.001) after rFVIIa. No thrombotic events were observed. Conclusion: The need for blood transfusion during complex and emergency cardiac surgery was significantly reduced with rFVIIa administration, which was judged effective in the management of bleeding during cardiac surgery. Large-scale trials are needed to optimize its use in cardiac surgery.
- 14 August 2026
- Published by Wolters Kluwer Health in Annals of Medicine & Surgery
- Vol. 88 (9) , 5620-5625
Open AccessEvaluating the efficacy of recombinant factor VIIa for non-surgical persistent bleeding in cardiovascular surgery: a retrospective cohort study
Background: Persistent bleeding after cardiovascular surgery challenges hemostatic management, especially in pediatric patients, but recombinant activated factor VIIa (rFVIIa), when used as a procoagulant, may improve patient outcomes. Materials and methods: We retrospectively evaluated 34 cardiac surgery patients who received recombinant rFVIIa for nonsurgical bleeding. Data on patient characteristics, surgical technique, rFVIIa administration, blood product use, complications, and hemostatic evaluation were collected. Red blood cell (RBC) transfusion volumes for 1 hour before and after rFVIIa administration were compared via a paired t -test. Results: Nineteen adult patients (mean age, 56.3 ± 15.3 years) and 15 pediatric patients [neonates (birth to 28 days), 7/15; infants (29 days to 1 year), 7/15; and preschoolers (3–6 years), 1/15] were included. RBC transfusion volumes were significantly reduced in adults (mean difference, 192.6 mL; 95% CI, 128.8–256.4 mL; P value < 0.001) and pediatric patients (mean difference, 37.0 mL/kg; 95% CI, 29.3–44.6 mL/kg; P value < 0.001) after rFVIIa. No thrombotic events were observed. Conclusion: The need for blood transfusion during complex and emergency cardiac surgery was significantly reduced with rFVIIa administration, which was judged effective in the management of bleeding during cardiac surgery. Large-scale trials are needed to optimize its use in cardiac surgery.
- 12 June 2025
- Published by Wiley in International Journal of Laboratory Hematology
- Vol. 47 (6) , 1128-1136
Effects of Artificial Lung and Roller Pump on Platelet Morphology and Activation During Simulated Extracorporeal Circulation
Introduction: Prolonged extracorporeal circulation time is known to cause intraoperative and postoperative bleeding, but the underlying mechanism is not fully understood. In this study, we analyzed the effects of artificial lung and roller pump on platelet morphology and activation using a simulated extracorporeal circulatory circuit. Methods: Blood was drawn from healthy volunteers in the presence of unfractionated heparin as an anticoagulant and recirculated for 180 min at 0.75 L/min with the circuit under a room temperature. After the samples were collected, platelet counts, platelet surface markers, and platelet activation markers were measured. Results: When whole blood was circulated for 180 min, platelet counts, platelet sizes, and expressions of glycoprotein Ibα (CD42b) and glycoprotein IIb (CD41) significantly decreased after recirculation. In addition, dense bodies and α‐granules within platelets were also reduced after recirculation. Adhesion to collagen and platelet aggregation were significantly reduced after recirculation compared to pro‐circulation. When platelets were stimulated with A23187 pro‐ and post‐extracorporeal circulation, the expression of P‐selectin was significantly lower in CD42b − platelets than in CD42b + platelets. On the other hand, phosphatidylserine (PS) exposure in CD42b − platelets was higher than in CD42b + platelets with or without stimulation. Conclusion: It was suggested that artificial lungs and roller pumps may reduce platelet activity by causing cleavage of platelet membrane glycoproteins and release of granules within platelets.
- 12 June 2025
- Published by Wiley in International Journal of Laboratory Hematology
- Vol. 47 (6) , 1128-1136
Effects of Artificial Lung and Roller Pump on Platelet Morphology and Activation During Simulated Extracorporeal Circulation
Introduction: Prolonged extracorporeal circulation time is known to cause intraoperative and postoperative bleeding, but the underlying mechanism is not fully understood. In this study, we analyzed the effects of artificial lung and roller pump on platelet morphology and activation using a simulated extracorporeal circulatory circuit. Methods: Blood was drawn from healthy volunteers in the presence of unfractionated heparin as an anticoagulant and recirculated for 180 min at 0.75 L/min with the circuit under a room temperature. After the samples were collected, platelet counts, platelet surface markers, and platelet activation markers were measured. Results: When whole blood was circulated for 180 min, platelet counts, platelet sizes, and expressions of glycoprotein Ibα (CD42b) and glycoprotein IIb (CD41) significantly decreased after recirculation. In addition, dense bodies and α‐granules within platelets were also reduced after recirculation. Adhesion to collagen and platelet aggregation were significantly reduced after recirculation compared to pro‐circulation. When platelets were stimulated with A23187 pro‐ and post‐extracorporeal circulation, the expression of P‐selectin was significantly lower in CD42b − platelets than in CD42b + platelets. On the other hand, phosphatidylserine (PS) exposure in CD42b − platelets was higher than in CD42b + platelets with or without stimulation. Conclusion: It was suggested that artificial lungs and roller pumps may reduce platelet activity by causing cleavage of platelet membrane glycoproteins and release of granules within platelets.
- Open Access
- 7 April 2025
- Published by Springer Nature in General Thoracic and Cardiovascular Surgery Cases
- Vol. 4 (1) , 1-5
Successfully repaired adult cor triatriatum with mitral regurgitation and atrial fibrillation: a case report
Background: Rarely seen in adults, cor triatriatum is a congenital defect in which a membrane creates three atrial chambers in the heart. Atrial fibrillation (AF) is the most common complication, but repair procedures in adults remain unestablished. Case presentation: A 49-year-old woman had cor triatriatum sinister (Lucas-Schmidt classification type I-A) with moderate mitral regurgitation and atrial fibrillation. Communication between the accessory chamber and the main chamber was established via a 10-mm fenestration with a pressure gradient of 14 mmHg. Mitral valve repair and the maze procedure, via radiofrequency ablation, was done after complete resection of the anomalous septum in the left atrium. Mitral regurgitation was well-controlled and atrial fibrillation disappeared. Sinus rhythm has been continually maintained at 6 months post-surgery, with no mitral regurgitation recurrence. Conclusions: Here, a rare adult cor triatriatum case with simultaneous mitral valve regurgitation and atrial fibrillation was treated with good results. The maze procedure shows effectiveness for atrial fibrillation associated with cor triatriatum. Especially the anomalous membrane attachments must be resolved in addition to the conventional maze procedure because electrical mapping of Cor triatriatum sinister showed low-voltage zones at the membrane attachments and it cause macro-reentrant atrial tachycardia.
- 7 April 2025
- Published by Springer Nature in General Thoracic and Cardiovascular Surgery Cases
- Vol. 4 (1) , 1-5
Open AccessSuccessfully repaired adult cor triatriatum with mitral regurgitation and atrial fibrillation: a case report
Background: Rarely seen in adults, cor triatriatum is a congenital defect in which a membrane creates three atrial chambers in the heart. Atrial fibrillation (AF) is the most common complication, but repair procedures in adults remain unestablished. Case presentation: A 49-year-old woman had cor triatriatum sinister (Lucas-Schmidt classification type I-A) with moderate mitral regurgitation and atrial fibrillation. Communication between the accessory chamber and the main chamber was established via a 10-mm fenestration with a pressure gradient of 14 mmHg. Mitral valve repair and the maze procedure, via radiofrequency ablation, was done after complete resection of the anomalous septum in the left atrium. Mitral regurgitation was well-controlled and atrial fibrillation disappeared. Sinus rhythm has been continually maintained at 6 months post-surgery, with no mitral regurgitation recurrence. Conclusions: Here, a rare adult cor triatriatum case with simultaneous mitral valve regurgitation and atrial fibrillation was treated with good results. The maze procedure shows effectiveness for atrial fibrillation associated with cor triatriatum. Especially the anomalous membrane attachments must be resolved in addition to the conventional maze procedure because electrical mapping of Cor triatriatum sinister showed low-voltage zones at the membrane attachments and it cause macro-reentrant atrial tachycardia.
- Open Access
- 4 March 2025
- Published by Elsevier in Annals of Thoracic Surgery Short Reports
- Vol. 3 (3) , 672-675
Mitral Valve Posterior Leaflet Extension by Fresh, Autologous Pericardium in an Infant: Long-term Results
- 4 March 2025
- Published by Elsevier in Annals of Thoracic Surgery Short Reports
- Vol. 3 (3) , 672-675
Open AccessMitral Valve Posterior Leaflet Extension by Fresh, Autologous Pericardium in an Infant: Long-term Results
- 25 June 2024
- Published by Springer Nature in Journal of Artificial Organs
- Vol. 28 (1) , 61-68
Aortic valve area index values of Trifecta implants correlate with energy loss and increased valve stress
Biological valves are becoming more frequently used in aortic valve replacement. While several reports have evaluated the performance of biological valves, echocardiography studies during exercise stress remain scarce. Furthermore, no current reports compare rate changes in the aortic valve area of biological valves under increased exercise load. Here, we performed exercise stress echocardiography in patients after AVR with Trifecta or Inspiris valves and compared the rates of change in aortic valve areas (AVA). In addition, hydrodynamic analysis at rest was conducted with four-dimensional flow magnetic resonance imaging (4D-flow MRI). Exercise stress echocardiography was performed in seven Trifecta and seven Inspiris patients who underwent AVR at our hospital while 4D flow MRI was performed in all but two Trifecta cases. Comparing the percentage change in AVA when loaded to 25 W versus at rest, Trifecta was greater than Inspiris (28.7 ± 36.0 vs − 0.8 ± 12.4%). The smaller AVA at rest was considered causative for this. Meanwhile, Trifecta systolic energy loss in the prosthetic valve segment on 4D-flow MRI (97.5 ± 35.9 vs 52.7 ± 25.3 mW) was higher than Inspiris. The opening of the Trifecta valve was considered to be restricted at rest and this may reflect the current reports of early valve degradation requiring reoperation. Taken together, we observed that the Trifecta design may promote faster wear due to higher valve stress.
- 25 June 2024
- Published by Springer Nature in Journal of Artificial Organs
- Vol. 28 (1) , 61-68
Aortic valve area index values of Trifecta implants correlate with energy loss and increased valve stress
Biological valves are becoming more frequently used in aortic valve replacement. While several reports have evaluated the performance of biological valves, echocardiography studies during exercise stress remain scarce. Furthermore, no current reports compare rate changes in the aortic valve area of biological valves under increased exercise load. Here, we performed exercise stress echocardiography in patients after AVR with Trifecta or Inspiris valves and compared the rates of change in aortic valve areas (AVA). In addition, hydrodynamic analysis at rest was conducted with four-dimensional flow magnetic resonance imaging (4D-flow MRI). Exercise stress echocardiography was performed in seven Trifecta and seven Inspiris patients who underwent AVR at our hospital while 4D flow MRI was performed in all but two Trifecta cases. Comparing the percentage change in AVA when loaded to 25 W versus at rest, Trifecta was greater than Inspiris (28.7 ± 36.0 vs − 0.8 ± 12.4%). The smaller AVA at rest was considered causative for this. Meanwhile, Trifecta systolic energy loss in the prosthetic valve segment on 4D-flow MRI (97.5 ± 35.9 vs 52.7 ± 25.3 mW) was higher than Inspiris. The opening of the Trifecta valve was considered to be restricted at rest and this may reflect the current reports of early valve degradation requiring reoperation. Taken together, we observed that the Trifecta design may promote faster wear due to higher valve stress.
- Open Access
- 28 November 2023
- Published by Oxford University Press (OUP) in Interdisciplinary CardioVascular and Thoracic Surgery
- Vol. 37 (6)
Effect of cardiopulmonary bypass on coagulation factors II, VII and X in a primate model: an exploratory pilot study
The use of cardiopulmonary bypass (CPB) in cardiac surgery is a major risk factor for postoperative bleeding. We hypothesized that consumptive coagulopathy and haemodilution influence the coagulation factors; therefore, we aimed to estimate the activity profiles of coagulation factors II, VII and X during CPB circulation. A 120-min bypass was surgically established in cynomolgus monkeys (n = 7). Activities of coagulation factors II, VII and X were measured at 6 time points during the experiment (baseline, 0, 30, 60, 120 min of bypass and 60 min after bypass). To assess the influence of consumptive coagulopathy, the values were adjusted for haemodilution using the haematocrit values. Data were expressed as mean (standard deviation). Activities of coagulation factors decreased during the experiment. In particular, the activities for II, VII and X were decreased the most by 44.2% (5.0), 61.4% (4.3) and 49.0% (3.7) at 30 min following CPB initiation (P < 0.001, P < 0.001 and P < 0.001, respectively). Following adjustments for haemodilution, change magnitudes lessened but remained significant for factor VII. The adjusted concentration of factor VII was observed to decrease from the baseline to the initiation of bypass circulation. In conclusion, coagulation factor II, VII and X concentrations decreased during CPB. Following adjustment for haemodilution, a decrease in concentration was observed with factor VII.
- 28 November 2023
- Published by Oxford University Press (OUP) in Interdisciplinary CardioVascular and Thoracic Surgery
- Vol. 37 (6)
Open AccessEffect of cardiopulmonary bypass on coagulation factors II, VII and X in a primate model: an exploratory pilot study
The use of cardiopulmonary bypass (CPB) in cardiac surgery is a major risk factor for postoperative bleeding. We hypothesized that consumptive coagulopathy and haemodilution influence the coagulation factors; therefore, we aimed to estimate the activity profiles of coagulation factors II, VII and X during CPB circulation. A 120-min bypass was surgically established in cynomolgus monkeys (n = 7). Activities of coagulation factors II, VII and X were measured at 6 time points during the experiment (baseline, 0, 30, 60, 120 min of bypass and 60 min after bypass). To assess the influence of consumptive coagulopathy, the values were adjusted for haemodilution using the haematocrit values. Data were expressed as mean (standard deviation). Activities of coagulation factors decreased during the experiment. In particular, the activities for II, VII and X were decreased the most by 44.2% (5.0), 61.4% (4.3) and 49.0% (3.7) at 30 min following CPB initiation (P < 0.001, P < 0.001 and P < 0.001, respectively). Following adjustments for haemodilution, change magnitudes lessened but remained significant for factor VII. The adjusted concentration of factor VII was observed to decrease from the baseline to the initiation of bypass circulation. In conclusion, coagulation factor II, VII and X concentrations decreased during CPB. Following adjustment for haemodilution, a decrease in concentration was observed with factor VII.
- 31 January 2022
- Published by Elsevier in The Annals of Thoracic Surgery
- Vol. 114 (5) , e335-e337
Expanded Polytetrafluoroethylene Patching for Recurrent Pulmonary Venous Obstructions
- 31 January 2022
- Published by Elsevier in The Annals of Thoracic Surgery
- Vol. 114 (5) , e335-e337
Expanded Polytetrafluoroethylene Patching for Recurrent Pulmonary Venous Obstructions
- 17 January 2022
- Published by Springer Nature in General Thoracic and Cardiovascular Surgery
- Vol. 70 (3) , 292-294
Two cases of catastrophic deterioration and multiple leaflet detachment in Trifecta valves
Reports of early and catastrophic acute structural valve deterioration (SVD) in Trifecta valve (Abbott, St Paul, MN, USA) with multiple leaflet detachment are rare. We encountered two cases of early SVD in Trifecta valve with tears on two leaflets. Both cases presented with acute heart failure because of aortic insufficiency, and underwent redo aortic valve replacement; one patient died due to multiple organ failure caused by cardiogenic shock. Durability issues with the Trifecta valves; thus, necessitates long-term vigilance in aortic replacement patients.
- 17 January 2022
- Published by Springer Nature in General Thoracic and Cardiovascular Surgery
- Vol. 70 (3) , 292-294
Two cases of catastrophic deterioration and multiple leaflet detachment in Trifecta valves
Reports of early and catastrophic acute structural valve deterioration (SVD) in Trifecta valve (Abbott, St Paul, MN, USA) with multiple leaflet detachment are rare. We encountered two cases of early SVD in Trifecta valve with tears on two leaflets. Both cases presented with acute heart failure because of aortic insufficiency, and underwent redo aortic valve replacement; one patient died due to multiple organ failure caused by cardiogenic shock. Durability issues with the Trifecta valves; thus, necessitates long-term vigilance in aortic replacement patients.
- 22 September 2021
- Published by Oxford University Press (OUP) in European Journal of Cardio-Thoracic Surgery
- Vol. 62 (1)
Conduction disorders after perimembranous ventricular septal defect closure: continuous versus interrupted suturing techniques
OBJECTIVES: The aim of this study was to investigate postoperative conduction disorder differences between continuous and interrupted suturing techniques for the closure of perimembranous outlet-type ventricular septal defects (VSDs) in both tetralogy of Fallot (ToF) and isolated VSD cases. METHODS: Patients aged 4 years or younger who underwent VSD closure for ToF (n = 112) or isolated perimembranous outlet-type VSD (n = 73) from April 2010 to December 2018 at 3 centres were reviewed. Patients either received continuous suturing for ToF (C-ToF, n = 58) or isolated VSD (C-VSD, n = 50), or interrupted suturing for ToF (I-ToF, n = 54) or isolated VSD (I-VSD, n = 23). Cohorts did not differ in preoperative characteristics. Postoperative conduction disorder differences upon discharge and postoperative year 1 (POY1) were evaluated by electrocardiography. RESULTS: The C-ToF group showed significantly shorter PQ intervals (124.0 vs 133.5 ms; P = 0.042 upon discharge, 125.3 vs 133.5 ms; P = 0.045 at POY1) and QRS durations (98.0 vs 106.2 ms; P = 0.031 upon discharge, 97.3 vs 102.5 ms; P = 0.040 at POY1) than the I-ToF group. Right bundle branch block incidence was significantly lower in the C-ToF versus I-ToF groups (56.8 vs 75.9; P = 0.045 upon discharge, 56.8 vs 75.9; P = 0.045 at POY1). Heart rates were significantly lower in the C-ToF versus I-ToF groups at POY1 (109.2 vs 119.3 bpm; P < 0.001). No parameters significantly differed between C-VSD and I-VSD groups. Multivariable analyses confirmed the group (C-ToF versus I-ToF) as a significant covariate in postoperative heart rate, PQ interval, QRS duration and right bundle branch block outcomes at POY1 (P = 0.013, 0.027, 0.013 and 0.014, respectively). CONCLUSIONS: A continuous suturing technique for the closure of outlet-type VSD in ToF could reduce the incidence of postoperative right bundle branch block, shorten the PQ interval and lower heart rate. Subject collection: 110, 138, 139.
- 22 September 2021
- Published by Oxford University Press (OUP) in European Journal of Cardio-Thoracic Surgery
- Vol. 62 (1)
Conduction disorders after perimembranous ventricular septal defect closure: continuous versus interrupted suturing techniques
OBJECTIVES: The aim of this study was to investigate postoperative conduction disorder differences between continuous and interrupted suturing techniques for the closure of perimembranous outlet-type ventricular septal defects (VSDs) in both tetralogy of Fallot (ToF) and isolated VSD cases. METHODS: Patients aged 4 years or younger who underwent VSD closure for ToF (n = 112) or isolated perimembranous outlet-type VSD (n = 73) from April 2010 to December 2018 at 3 centres were reviewed. Patients either received continuous suturing for ToF (C-ToF, n = 58) or isolated VSD (C-VSD, n = 50), or interrupted suturing for ToF (I-ToF, n = 54) or isolated VSD (I-VSD, n = 23). Cohorts did not differ in preoperative characteristics. Postoperative conduction disorder differences upon discharge and postoperative year 1 (POY1) were evaluated by electrocardiography. RESULTS: The C-ToF group showed significantly shorter PQ intervals (124.0 vs 133.5 ms; P = 0.042 upon discharge, 125.3 vs 133.5 ms; P = 0.045 at POY1) and QRS durations (98.0 vs 106.2 ms; P = 0.031 upon discharge, 97.3 vs 102.5 ms; P = 0.040 at POY1) than the I-ToF group. Right bundle branch block incidence was significantly lower in the C-ToF versus I-ToF groups (56.8 vs 75.9; P = 0.045 upon discharge, 56.8 vs 75.9; P = 0.045 at POY1). Heart rates were significantly lower in the C-ToF versus I-ToF groups at POY1 (109.2 vs 119.3 bpm; P < 0.001). No parameters significantly differed between C-VSD and I-VSD groups. Multivariable analyses confirmed the group (C-ToF versus I-ToF) as a significant covariate in postoperative heart rate, PQ interval, QRS duration and right bundle branch block outcomes at POY1 (P = 0.013, 0.027, 0.013 and 0.014, respectively). CONCLUSIONS: A continuous suturing technique for the closure of outlet-type VSD in ToF could reduce the incidence of postoperative right bundle branch block, shorten the PQ interval and lower heart rate. Subject collection: 110, 138, 139.
- 4 July 2020
- Published by Springer Nature in Journal of Artificial Organs
- Vol. 24 (1) , 22-26
The effect of roller head pump on platelet deterioration during the simulated extracorporeal circulation
Roller pumping results in hemolysis and adverse effects on coagulation, but there are few reports on the influence of roller heads on platelets. Here, we evaluate the interaction between roller pumping and platelet function using a simulated extracorporeal circuit incorporating a vinyl chloride tube and roller head pump with 30 min recirculation. Platelet aggregation, platelet count, microparticle, P-selectin, Phosphatidylserine (PS) exposure and Ricinus Communis Agglutinin 1 (RCA-1) were measured before, 5, 10, 20, and 30 min after the recirculation using 100 ml of fresh human blood that had obtained from healthy volunteers (n = 9). Platelet aggregation and platelet count gradually decreased but microparticles significantly increased after the recirculation (P < 0.05). P-selectin, PS exposure and RCA-1 were measured using flow cytometry. There were no significant differences in the P-selectin and PS exposure expression during recirculation. RCA-1, a platelet apoptosis markers, significantly increased 30 min after recirculation (P < 0.05). We thus conclude that roller pumping induced platelet apoptosis and caused decreases in platelet count and aggregation after the recirculation.
- 4 July 2020
- Published by Springer Nature in Journal of Artificial Organs
- Vol. 24 (1) , 22-26
The effect of roller head pump on platelet deterioration during the simulated extracorporeal circulation
Roller pumping results in hemolysis and adverse effects on coagulation, but there are few reports on the influence of roller heads on platelets. Here, we evaluate the interaction between roller pumping and platelet function using a simulated extracorporeal circuit incorporating a vinyl chloride tube and roller head pump with 30 min recirculation. Platelet aggregation, platelet count, microparticle, P-selectin, Phosphatidylserine (PS) exposure and Ricinus Communis Agglutinin 1 (RCA-1) were measured before, 5, 10, 20, and 30 min after the recirculation using 100 ml of fresh human blood that had obtained from healthy volunteers (n = 9). Platelet aggregation and platelet count gradually decreased but microparticles significantly increased after the recirculation (P < 0.05). P-selectin, PS exposure and RCA-1 were measured using flow cytometry. There were no significant differences in the P-selectin and PS exposure expression during recirculation. RCA-1, a platelet apoptosis markers, significantly increased 30 min after recirculation (P < 0.05). We thus conclude that roller pumping induced platelet apoptosis and caused decreases in platelet count and aggregation after the recirculation.