Q-onset and T-end delineation: assessment of the performance of an automated method with the use of a reference database
Authors:
- I ChristovICI Christov
- I SimovaISI Simova
- 12 January 2007
- journal article
- Published by IOP Publishing in Physiological Measurement
- Vol. 28 (2) , 213-221
Abstract
The aim of the study is to assess the performance of an automated method for Q-onset and T-end delineation, as well as QT measurement with the use of a 'gold standard' of a manually created reference database. The data to be used comprise 548 recordings of the PTB Diagnostic ECG Database. The ECG signals are preprocessed, suppressing power-line interference, electromyographic noise and baseline drift according to our previously published investigations, guaranteeing accurate Q-onset and T-end locality preservation. Our method for automatic detection of Q-onset and T-end is based on the minimum value of the angle between two segments having a common mid point and equal lengths of 10 ms. The minimum of the angle is searched in defined time intervals delimited separately for the Q-onset and T-end. All measurements are performed on lead II only. Mean +/- standard deviations are obtained for 95% of the recordings: -0.08 +/- 2.71 for Q-onset, 5.10 +/- 9.22 for T-end and 4.40 +/- 9.93 for QT interval, as well as for 100% of the recordings: 0.46 +/- 4.84 for Q-onset, 1.28 +/- 16.75 for T-end and 0.83 +/- 16.67 for QT interval.Keywords
This publication has 10 references indexed in Scilit:
- Precision of QT Interval Measurement by Advanced Electrocardiographic EquipmentPacing and Clinical Electrophysiology, 2006
- Dataset of manually measured QT intervals in the electrocardiogramBioMedical Engineering OnLine, 2006
- Which Lead for Q-T Interval Measurements?Cardiology, 2000
- Filtering of electromyogram artifacts from the electrocardiogramMedical Engineering & Physics, 1999
- Automatic detection of the electrocardiogram T-wave endMedical & Biological Engineering & Computing, 1999
- Electrocardiogram signal preprocessing for automatic detection of QRS boundariesMedical Engineering & Physics, 1999
- Developments in ECG acquisition, preprocessing, parameter measurement, and recordingIEEE Engineering in Medicine and Biology Magazine, 1998
- The importance of derived 12-lead electrocardiography in the interpretation of arrhythmias detected by Holter recordingAmerican Heart Journal, 1992
- Multilead ECG analysisComputers and Biomedical Research, 1986
- Assessment of the performance of electrocardiographic computer programs with the use of a reference data base.Circulation, 1985