Electrical parameters of soils in the frequency range from 1 kHz to 1 GHz, using lumped‐circuit methods
Authors:
- Ben K. SternbergBSBen K. Sternberg
- Tsylya M. LevitskayaTLTsylya M. Levitskaya
- 1 July 2001
- journal article
- Published by American Geophysical Union (AGU) in Radio Science
- Vol. 36 (4) , 709-719
Abstract
For studying electrical properties of soil samples with various compositions and water contents, we applied a lumped‐circuit approach. The extension of this method up to 1GHz was made possible by using a coaxial sample holder. The complex electrical parameters of soils, such as the relative permittivity , conductivity , and resistivity , were obtained by measuring the magnitude Z and phase ϕ of the sample impedance . The experimental setup is described in our previous paper [Levitskaya and Sternberg, 2000]. The relative real permittivity ε′ and imaginary permittivity (dielectric losses) ε″ for high‐loss soils from Arizona decrease with frequency and increase with water content. Regression equations, derived for the relative permittivity ε′ versus water content at a given frequency, can be used to determine the water content in soil from ε′ data. The third‐degree polynomial equations, which relate the relative permittivity to the volumetric soil moisture content, are different for various frequencies. The complex electrical resistivity components ρ′ and ρ″ reveal a time‐dependent polarization process at frequencies above 1 MHz, which shifts to higher frequencies with increasing water content. The propagation parameters, such as attenuation constant α, phase velocity Vp, and penetration depth P, which we calculated from the electrical parameters, also depend on soil wetness. Our comparison of the electrical and propagation parameters for different soils shows that the high‐loss soil samples from Avra Valley, Arizona, have higher values ε′ and ε″, higher attenuation constant α, and lower penetration depth P than the low‐loss soils from Brookhaven, New York. For example, at 500 MHz, a high‐loss soil (Avra Valley) with volumetric moisture content of ∼10%, exhibits an attenuation of 43 dB/m, whereas for a low‐loss soil (Brookhaven) with the same wetness the attenuation constant is only 4 dB/m. We also note that very dry, clean sand in a sheltered “sand box,” which is a favorite medium for testing ground‐penetrating radar (GPR), is usually not representative of natural conditions. Therefore, GPR data from such “sand box” experiments must be used with considerable caution because they yield unrealistically large penetration depths and unnatural target responses.Keywords
This publication has 20 references indexed in Scilit:
- Laboratory measurement of material electrical properties: Extending the application of lumped‐circuit equivalent models to 1 GHzRadio Science, 2000
- A New Method of Subsurface Imaging—The LASI High Frequency Ellipticity System: Part 3. System Tests and Field SurveysJournal of Environmental and Engineering Geophysics, 1999
- Correlation between Laboratory and In Situ Electrical Resistivity Measurements of SoilJournal of Environmental and Engineering Geophysics, 1998
- Effects of laboratory procedures on soil electrical property measurementsIEEE Transactions on Instrumentation and Measurement, 1998
- Microstrip ring resonator for soil moisture measurementsIEEE Transactions on Geoscience and Remote Sensing, 1997
- Dielectric properties of soils in the 0.3-1.3-GHz rangeIEEE Transactions on Geoscience and Remote Sensing, 1995
- Archaeology studies in southern Arizona using ground penetrating radarJournal of Applied Geophysics, 1995
- Dielectric Properties and Influence of Conductivity in Soils at One to Fifty MegahertzSoil Science Society of America Journal, 1990
- Relaxation phenomena and induced polarizationGeoexploration, 1984
- The dielectric properties of soil‐water mixtures at microwave frequenciesRadio Science, 1980