Hardware implementation of all digital calibration for undersampling TIADCs
Authors:
- 1 May 2015
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 02714302,p. 2181-2184
Abstract
This paper presents a practical implementation of all digital calibration algorithm for the gain and timing mismatches in undersampling Time-Interleaved Analog-to-Digital Converter (TI-ADC). A new Least Mean Square (LMS) based detection scheme is proposed to increase convergence speed as well as to enhance the estimate accuracy. Monte Carlo simulations for a four-channel undersampling 60 dB SNR TI-ADC clocked at 2.7 GHz show that SFDR can achieve approximately 90 dB SFDR within the stable point of the channel mismatch coefficients over the first three Nyquist Bands. The proposed architecture is implemented and validated on the Altera FPGA DE4 board. The synthesized design consumes a few percentages of the hardware resources of the FPGA chip and work properly on a Hardware-In-the-Loop emulation framework.Keywords
This publication has 11 references indexed in Scilit:
- A fully digital background calibration of timing skew in undersampling TI-ADC2014
- 22.5 A 1.62GS/s time-interleaved SAR ADC with digital background mismatch calibration achieving interleaving spurs below 70dBFS2014
- Design Considerations for Interleaved ADCsIEEE Journal of Solid-State Circuits, 2013
- All-Digital Background Calibration Technique for Time-Interleaved ADC Using Pseudo Aliasing SignalIEEE Transactions on Circuits and Systems I: Regular Papers, 2013
- A 2.8 GS/s 44.6 mW Time-Interleaved ADC Achieving 50.9 dB SNDR and 3 dB Effective Resolution Bandwidth of 1.5 GHz in 65 nm CMOSIEEE Journal of Solid-State Circuits, 2013
- Efficient Digital Background Calibration of Time-Interleaved Pipeline Analog-to-Digital ConvertersIEEE Transactions on Circuits and Systems I: Regular Papers, 2012
- Software Radio2012
- A 480mW 2.6GS/s 10b 65nm CMOS time-interleaved ADC with 48.5dB SNDR up to Nyquist2011
- A 12-GS/s 81-mW 5-bit time-interleaved flash ADC with background timing skew calibration2010
- Calibration of Sample-Time Error in a Two-Channel Time-Interleaved Analog-to-Digital ConverterIEEE Transactions on Circuits and Systems I: Regular Papers, 2004