A simple and rapid calibration methodology for industrial robot based on geometric constraint and two-step error
Authors:
- Jiabo ZhangJZJiabo Zhang
- Xibin WangXWXibin Wang
- Ke WenKWKe Wen
- Yinghao ZhouYZYinghao Zhou
- Yi YueYYYi Yue
- Jizhi YangJYJizhi Yang
- 30 October 2018
- journal article
- research article
- Published by Emerald Publishing in Industrial Robot: the international journal of robotics research and application
- Vol. 45 (6) , 715-721
Abstract
Purpose: The purpose of this study is the presentation and research of a simple and rapid calibration methodology for industrial robot. Extensive research efforts were devoted to meet the requirements of online compensation, closed-loop feedback control and high-precision machining during the flexible machining process of robot for large-scale cabin. Design/methodology/approach: A simple and rapid method to design and construct the transformation relation between the base coordinate system of robot and the measurement coordinate system was proposed based on geometric constraint. By establishing the Denavit–Hartenberg model for robot calibration, a method of two-step error for kinematic parameters calibration was put forward, which aided in achievement of step-by-step calibration of angle and distance errors. Furthermore, KUKA robot was considered as the research object, and related experiments were performed based on laser tracker. Findings: The experimental results demonstrated that the accuracy of the coordinate transformation could reach 0.128 mm, which meets the transformation requirements. Compared to other methods used in this study, the calibration method of two-step error could significantly improve the positioning accuracy of robot up to 0.271 mm. Originality/value: The methodology based on geometric constraint and two-step error is simple and can rapidly calibrate the kinematic parameters of robot. It also leads to the improvement in the positioning accuracy of robot.Keywords
This publication has 14 references indexed in Scilit:
- Calibration method of robot base frame using unit quaternion formPrecision Engineering, 2015
- A Method for Improving the Pose Accuracy of a Robot Manipulator Based on Multi-Sensor Combined Measurement and Data FusionSensors, 2015
- A calibration method for enhancing robot accuracy through integration of an extended Kalman filter algorithm and an artificial neural networkNeurocomputing, 2015
- Online robot calibration based on hybrid sensors using Kalman FiltersRobotics and Computer-Integrated Manufacturing, 2015
- Absolute accuracy analysis and improvement of a hybrid 6-DOF medical robotIndustrial Robot: the international journal of robotics research and application, 2015
- A distance error based industrial robot kinematic calibration methodIndustrial Robot: the international journal of robotics research and application, 2014
- Comparison of two calibration methods for a small industrial robot based on an optical CMM and a laser trackerRobotica, 2013
- Absolute calibration of an ABB IRB 1600 robot using a laser trackerRobotics and Computer-Integrated Manufacturing, 2013
- Kinematic Calibration Method of Robots Based on Distance ErrorRobot, 2013
- Method of robot calibration based on laser trackerChinese Journal of Mechanical Engineering, 2007