Yinghao Zhou
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Yinghao Zhou has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Ke Wen
Beijing Spacecrafts, China Academy of Space Technology, Beijing 100048, China
2 shared publications Dongliang Ren
China Academy of Space Technology
1 shared publication- Guanghui Chen
23rd Institute China Electronics Technology Group Corporation, Shanghai 201900, China
1 shared publication - Jiabo Zhang
Beijing Spacecrafts, China Academy of Space Technology, Beijing 100094, China
1 shared publication - Jie Xiong
Key Laboratory of the Ministry of Education for Optoelectronic Measurement Technology and Instrument, Beijing Information Science & Technology University, Beijing 100192, China
1 shared publication Jizhi Yang
1 shared publication
Latest Publications
- Open Access
- 24 March 2023
- Published by MDPI AG in Applied Sciences
- Vol. 13 (7) , 4161
Spectral Splitting Sensing Using Optical Fiber Bragg Grating for Spacecraft Lateral Stress Health Monitoring
Optical fiber sensing is a promising detection method for spacecraft health monitoring, since optical fiber sensors are lightweight, small in size, easy to integrate and immune to electromagnetic interference. As a significant optical sensor, fiber Bragg gratings (FBG) are widely used for force sensing because of their axial strain characteristics. However, it is necessary to detect not only one-dimensional strain but also plane strain and its deformation in order to comprehensively evaluate the condition of the structure. Therefore, it is very important to analyze the reflection spectrum of FBG under lateral stress. When FBG are subjected to lateral stress, the refractive index of the waveguide in the x and y directions changes, resulting in a birefringence phenomenon. This result causes the reflection spectrum of FBG to split into two peaks. In this paper, a transverse stress detection method based on spectral split sensing for the fiber Bragg grating is proposed, intended for monitoring spacecraft–small particle collisions. The FBG local lateral stress detection system is designed and verified by experiments. The wavelength pressure correlation is established in the experiment by adjusting the number of weights to change the lateral pressure on the FBG. The loading range of FBG lateral pressure is 4.0–7.0 N, the step size is 0.5 N, and round-trip measurement is carried out four times. The wavelengths of the peak and split point of the FBG reflection spectrum are recorded. The experimental results show that FBG’s split point and right peak pressure sensitivities are 16.57 pm/N and 45.14 pm/N, respectively. The spectral splitting phenomenon can be applied in spacecraft structure health monitoring systems and has certain reference value for the simplification of sensor systems.
- 24 March 2023
- Published by MDPI AG in Applied Sciences
- Vol. 13 (7) , 4161
Open AccessSpectral Splitting Sensing Using Optical Fiber Bragg Grating for Spacecraft Lateral Stress Health Monitoring
Optical fiber sensing is a promising detection method for spacecraft health monitoring, since optical fiber sensors are lightweight, small in size, easy to integrate and immune to electromagnetic interference. As a significant optical sensor, fiber Bragg gratings (FBG) are widely used for force sensing because of their axial strain characteristics. However, it is necessary to detect not only one-dimensional strain but also plane strain and its deformation in order to comprehensively evaluate the condition of the structure. Therefore, it is very important to analyze the reflection spectrum of FBG under lateral stress. When FBG are subjected to lateral stress, the refractive index of the waveguide in the x and y directions changes, resulting in a birefringence phenomenon. This result causes the reflection spectrum of FBG to split into two peaks. In this paper, a transverse stress detection method based on spectral split sensing for the fiber Bragg grating is proposed, intended for monitoring spacecraft–small particle collisions. The FBG local lateral stress detection system is designed and verified by experiments. The wavelength pressure correlation is established in the experiment by adjusting the number of weights to change the lateral pressure on the FBG. The loading range of FBG lateral pressure is 4.0–7.0 N, the step size is 0.5 N, and round-trip measurement is carried out four times. The wavelengths of the peak and split point of the FBG reflection spectrum are recorded. The experimental results show that FBG’s split point and right peak pressure sensitivities are 16.57 pm/N and 45.14 pm/N, respectively. The spectral splitting phenomenon can be applied in spacecraft structure health monitoring systems and has certain reference value for the simplification of sensor systems.
- 18 October 2021
- Published by Springer Nature
- p. 669-677
Positioning Accuracy Compensation Method of Mobile Robot Based on Inverse Distance Weight
- 18 October 2021
- Published by Springer Nature
- p. 669-677
Positioning Accuracy Compensation Method of Mobile Robot Based on Inverse Distance Weight
- 30 October 2018
- Published by Emerald Publishing in Industrial Robot: the international journal of robotics research and application
- Vol. 45 (6) , 715-721
A simple and rapid calibration methodology for industrial robot based on geometric constraint and two-step error
Purpose: The purpose of this study is the presentation and research of a simple and rapid calibration methodology for industrial robot. Extensive research efforts were devoted to meet the requirements of online compensation, closed-loop feedback control and high-precision machining during the flexible machining process of robot for large-scale cabin. Design/methodology/approach: A simple and rapid method to design and construct the transformation relation between the base coordinate system of robot and the measurement coordinate system was proposed based on geometric constraint. By establishing the Denavit–Hartenberg model for robot calibration, a method of two-step error for kinematic parameters calibration was put forward, which aided in achievement of step-by-step calibration of angle and distance errors. Furthermore, KUKA robot was considered as the research object, and related experiments were performed based on laser tracker. Findings: The experimental results demonstrated that the accuracy of the coordinate transformation could reach 0.128 mm, which meets the transformation requirements. Compared to other methods used in this study, the calibration method of two-step error could significantly improve the positioning accuracy of robot up to 0.271 mm. Originality/value: The methodology based on geometric constraint and two-step error is simple and can rapidly calibrate the kinematic parameters of robot. It also leads to the improvement in the positioning accuracy of robot.
- 30 October 2018
- Published by Emerald Publishing in Industrial Robot: the international journal of robotics research and application
- Vol. 45 (6) , 715-721
A simple and rapid calibration methodology for industrial robot based on geometric constraint and two-step error
Purpose: The purpose of this study is the presentation and research of a simple and rapid calibration methodology for industrial robot. Extensive research efforts were devoted to meet the requirements of online compensation, closed-loop feedback control and high-precision machining during the flexible machining process of robot for large-scale cabin. Design/methodology/approach: A simple and rapid method to design and construct the transformation relation between the base coordinate system of robot and the measurement coordinate system was proposed based on geometric constraint. By establishing the Denavit–Hartenberg model for robot calibration, a method of two-step error for kinematic parameters calibration was put forward, which aided in achievement of step-by-step calibration of angle and distance errors. Furthermore, KUKA robot was considered as the research object, and related experiments were performed based on laser tracker. Findings: The experimental results demonstrated that the accuracy of the coordinate transformation could reach 0.128 mm, which meets the transformation requirements. Compared to other methods used in this study, the calibration method of two-step error could significantly improve the positioning accuracy of robot up to 0.271 mm. Originality/value: The methodology based on geometric constraint and two-step error is simple and can rapidly calibrate the kinematic parameters of robot. It also leads to the improvement in the positioning accuracy of robot.