Suitability of Seismic Isolation for Buildings Founded on Soft Soil. Case Study of a RC Building in Shanghai
Open Access
Abstract
Base (seismic) isolation is a promising technology for seismic protection of buildings and other constructions. Nowadays, it is accepted that such a technique is efficient and reliable; however, it has two major limitations: soft foundation soil, and tall buildings. The first issue restrains the seismic isolation spreading, given that soft soil is frequent in densely populated areas, and usually such a soil type concentrates the highest seismicity levels. This paper aims to contribute to demonstrating that base isolation, if properly implemented, can be suitable for soft soil. A representative case study is analyzed: a 6-story reinforced concrete (RC) building with base isolation that has recently been built in Shanghai. Since the building is founded on soft soil, concern regarding base isolation suitability arose; even the Chinese design code does not recommend this solution for soft soil. To clarify this issue, non-linear time-history analyses are carried out for a number of natural and artificial seismic inputs that represent the site seismicity; the superstructure behavior is linear, while nonlinearities are concentrated in the isolation layer. The adequacy of base isolation is assessed in the superstructure (in terms of reduction of interstory drift, absolute acceleration and shear force) and in the isolation layer (in terms of axial force, torsion angle and shear strain). The relevance of soil–structure interaction is discussed. The behavior when the mechanical parameters of the isolation units have experienced important changes is also analyzed. The major conclusion is that base isolation of ordinary mid-height RC buildings founded on soft soil can perform satisfactorily in medium seismicity regions.Keywords
This publication has 18 references indexed in Scilit:
- Effects of soil–structure interaction on seismic base isolationSoil Dynamics and Earthquake Engineering, 2014
- Optimal integrated seismic design of structural and viscoelastic bracing‐damper systemsEarthquake Engineering & Structural Dynamics, 2014
- Seismic response of base-isolated buildings including soil–structure interactionSoil Dynamics and Earthquake Engineering, 2009
- Soil–structure interaction effects on base-isolated buildings founded on soil stratumEngineering Structures, 2009
- Seismic response analysis of structures with velocity-dependent dampersJournal of Constructional Steel Research, 2007
- Seismically isolated bridge piers on shallow soil stratum with soil–structure interactionComputers & Structures, 2001
- Optimum damping in linear isolation systemsEarthquake Engineering & Structural Dynamics, 1993
- 1. Seismic Isolation: History, Application, and Performance—A World ViewEarthquake Spectra, 1990
- Dynamics of Soil‐Base‐Isolated‐Structure SystemsJournal of Structural Engineering, 1988
- Aseismic base isolation: review and bibliographySoil Dynamics and Earthquake Engineering, 1986