Dagen Weng
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Dagen Weng has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Ruifu Zhang
Tongji University
2 shared publications - Bashar Alfarah
Civil and Environmental Engineering Department, Technical University of Catalonia, 08034 Barcelona, Spain
1 shared publication - Francisco López Almansa
Universitat Politècnica de Catalunya, Barcelona, Spain, Spain
1 shared publication - Hao Luo
School of Civil and Hydraulic Engineering, Huazhong University of Science and Technology, Wuhan, China
1 shared publication - Hao Wang
State Key Laboratory for Disaster Reduction in Civil Engineering, Tongji University, Shanghai 200092, China
1 shared publication - Qingjun Chen
State Key Laboratory of Disaster Reduction in Civil Engineering, Tongji University, Shanghai 200092, China
1 shared publication
Latest Publications
- Open Access
Suitability of Seismic Isolation for Buildings Founded on Soft Soil. Case Study of a RC Building in Shanghai
Base (seismic) isolation is a promising technology for seismic protection of buildings and other constructions. Nowadays, it is accepted that such a technique is efficient and reliable; however, it has two major limitations: soft foundation soil, and tall buildings. The first issue restrains the seismic isolation spreading, given that soft soil is frequent in densely populated areas, and usually such a soil type concentrates the highest seismicity levels. This paper aims to contribute to demonstrating that base isolation, if properly implemented, can be suitable for soft soil. A representative case study is analyzed: a 6-story reinforced concrete (RC) building with base isolation that has recently been built in Shanghai. Since the building is founded on soft soil, concern regarding base isolation suitability arose; even the Chinese design code does not recommend this solution for soft soil. To clarify this issue, non-linear time-history analyses are carried out for a number of natural and artificial seismic inputs that represent the site seismicity; the superstructure behavior is linear, while nonlinearities are concentrated in the isolation layer. The adequacy of base isolation is assessed in the superstructure (in terms of reduction of interstory drift, absolute acceleration and shear force) and in the isolation layer (in terms of axial force, torsion angle and shear strain). The relevance of soil–structure interaction is discussed. The behavior when the mechanical parameters of the isolation units have experienced important changes is also analyzed. The major conclusion is that base isolation of ordinary mid-height RC buildings founded on soft soil can perform satisfactorily in medium seismicity regions.
Open AccessSuitability of Seismic Isolation for Buildings Founded on Soft Soil. Case Study of a RC Building in Shanghai
Base (seismic) isolation is a promising technology for seismic protection of buildings and other constructions. Nowadays, it is accepted that such a technique is efficient and reliable; however, it has two major limitations: soft foundation soil, and tall buildings. The first issue restrains the seismic isolation spreading, given that soft soil is frequent in densely populated areas, and usually such a soil type concentrates the highest seismicity levels. This paper aims to contribute to demonstrating that base isolation, if properly implemented, can be suitable for soft soil. A representative case study is analyzed: a 6-story reinforced concrete (RC) building with base isolation that has recently been built in Shanghai. Since the building is founded on soft soil, concern regarding base isolation suitability arose; even the Chinese design code does not recommend this solution for soft soil. To clarify this issue, non-linear time-history analyses are carried out for a number of natural and artificial seismic inputs that represent the site seismicity; the superstructure behavior is linear, while nonlinearities are concentrated in the isolation layer. The adequacy of base isolation is assessed in the superstructure (in terms of reduction of interstory drift, absolute acceleration and shear force) and in the isolation layer (in terms of axial force, torsion angle and shear strain). The relevance of soil–structure interaction is discussed. The behavior when the mechanical parameters of the isolation units have experienced important changes is also analyzed. The major conclusion is that base isolation of ordinary mid-height RC buildings founded on soft soil can perform satisfactorily in medium seismicity regions.
- Open Access
- 1 January 2019
- Published by Wiley in Advances in Civil Engineering
- Vol. 2019 (1)
Estimation of Additional Equivalent Damping Ratio of the Damped Structure Based on Energy Dissipation
In the design of damped structures, the additional equivalent damping ratio (EDR) is an important factor in the evaluation of the energy dissipation effect. However, previous additional EDR estimation methods are complicated and not easy to be applied in practical engineering. Therefore, in this study, a method based on energy dissipation is developed to simplify the estimation of the additional EDR. First, an energy governing equation is established to calculate the structural energy dissipation. By means of dynamic analysis, the ratio of the energy consumed by dampers to that consumed by structural inherent damping is obtained under external excitation. Because the energy dissipation capacity of the installed dampers is reflected by the additional EDR, the abovementioned ratio can be used to estimate the additional EDR of the damped structure. Energy dissipation varies with time, which indicates that the ratio is related to the duration of ground motion. Hence, the energy dissipation during the most intensive period in the entire seismic motion duration is used to calculate the additional EDR. Accordingly, the procedure of the proposed method is presented. The feasibility of this method is verified by using a single‐degree‐of‐freedom system. Then, a benchmark structure with dampers is adopted to illustrate the usefulness of this method in practical engineering applications. In conclusion, the proposed method is not only explicit in the theoretical concept and convenient in application but also reflects the time‐varying characteristic of additional EDR, which possesses the value in practical engineering.
- 1 January 2019
- Published by Wiley in Advances in Civil Engineering
- Vol. 2019 (1)
Open AccessEstimation of Additional Equivalent Damping Ratio of the Damped Structure Based on Energy Dissipation
In the design of damped structures, the additional equivalent damping ratio (EDR) is an important factor in the evaluation of the energy dissipation effect. However, previous additional EDR estimation methods are complicated and not easy to be applied in practical engineering. Therefore, in this study, a method based on energy dissipation is developed to simplify the estimation of the additional EDR. First, an energy governing equation is established to calculate the structural energy dissipation. By means of dynamic analysis, the ratio of the energy consumed by dampers to that consumed by structural inherent damping is obtained under external excitation. Because the energy dissipation capacity of the installed dampers is reflected by the additional EDR, the abovementioned ratio can be used to estimate the additional EDR of the damped structure. Energy dissipation varies with time, which indicates that the ratio is related to the duration of ground motion. Hence, the energy dissipation during the most intensive period in the entire seismic motion duration is used to calculate the additional EDR. Accordingly, the procedure of the proposed method is presented. The feasibility of this method is verified by using a single‐degree‐of‐freedom system. Then, a benchmark structure with dampers is adopted to illustrate the usefulness of this method in practical engineering applications. In conclusion, the proposed method is not only explicit in the theoretical concept and convenient in application but also reflects the time‐varying characteristic of additional EDR, which possesses the value in practical engineering.
- 17 July 2016
- Published by ASME International
A Hybrid Control Method to Reduce the Seismic Response of a Liquid Storage Tank
In this study, a hybrid control method is proposed, in which both isolation bearings and an inertial mass damper (IMD) are used, to reduce the seismic response of a liquid storage tank. First, simplified models of the tank and IMD are illustrated. Next, to evaluate the effectiveness of the proposed method, three tanks, including a fixed tank, an isolated tank and an isolated tank with an IMD, are analyzed and compared. Last, parametric studies are conducted to investigate the effects of equivalent inertial mass and viscous damping of the IMD. It is observed that, compared with the fixed tank, the base shear of the isolated one is largely reduced, whereas the wave height is consequently amplified; for the isolated tank with an IMD, not only is the base shear more obviously reduced, but also the wave height is effectively controlled. What’s more, the base displacement of the isolated tank with an IMD is much lower than that of the isolated one. Therefore, the proposed method can be considered as an effective method to control the seismic response of the liquid storage tanks.
- 17 July 2016
- Published by ASME International
A Hybrid Control Method to Reduce the Seismic Response of a Liquid Storage Tank
In this study, a hybrid control method is proposed, in which both isolation bearings and an inertial mass damper (IMD) are used, to reduce the seismic response of a liquid storage tank. First, simplified models of the tank and IMD are illustrated. Next, to evaluate the effectiveness of the proposed method, three tanks, including a fixed tank, an isolated tank and an isolated tank with an IMD, are analyzed and compared. Last, parametric studies are conducted to investigate the effects of equivalent inertial mass and viscous damping of the IMD. It is observed that, compared with the fixed tank, the base shear of the isolated one is largely reduced, whereas the wave height is consequently amplified; for the isolated tank with an IMD, not only is the base shear more obviously reduced, but also the wave height is effectively controlled. What’s more, the base displacement of the isolated tank with an IMD is much lower than that of the isolated one. Therefore, the proposed method can be considered as an effective method to control the seismic response of the liquid storage tanks.
- 15 September 2014
- Published by ASME International in Journal of Pressure Vessel Technology
- Vol. 137 (1) , 011801
Life-Cycle Cost Assessment of Seismically Base-Isolated Large Tanks in Liquefied Natural Gas Plants
A new methodology is being introduced to address the life-cycle cost (LCC) of base-isolated large liquefied natural gas (LNG) tanks. The relationship between LCC and seismic fortification intensity was established to evaluate how much earthquake force being isolated can minimize LCC. Each composition of LCC was analyzed including the initial cost, the isolators' cost, and the excepted damage cost. The isolators' cost consists of the cost of laminated lead rubber bearings (LLRB) and supplemental dampers. The cost of LLRB was proposed proportional to its volume and the proposed cost of supplemental dampers was not only related to its maximum displacement but also to its tonnage. The concept of seismic intensity was being used to estimate the expected damage cost, greatly simplifying the calculation. Moreover, a tank in a LNG receiving terminal in China was employed as an example, the LCC of which was assessed in isolated and nonisolated situation, respectively. The results showed that the proposed method was efficient and the expected damage cost was enormously reduced because of the application of isolation, which leaded to the reduction of the LCC of the tank.
- 15 September 2014
- Published by ASME International in Journal of Pressure Vessel Technology
- Vol. 137 (1) , 011801
Life-Cycle Cost Assessment of Seismically Base-Isolated Large Tanks in Liquefied Natural Gas Plants
A new methodology is being introduced to address the life-cycle cost (LCC) of base-isolated large liquefied natural gas (LNG) tanks. The relationship between LCC and seismic fortification intensity was established to evaluate how much earthquake force being isolated can minimize LCC. Each composition of LCC was analyzed including the initial cost, the isolators' cost, and the excepted damage cost. The isolators' cost consists of the cost of laminated lead rubber bearings (LLRB) and supplemental dampers. The cost of LLRB was proposed proportional to its volume and the proposed cost of supplemental dampers was not only related to its maximum displacement but also to its tonnage. The concept of seismic intensity was being used to estimate the expected damage cost, greatly simplifying the calculation. Moreover, a tank in a LNG receiving terminal in China was employed as an example, the LCC of which was assessed in isolated and nonisolated situation, respectively. The results showed that the proposed method was efficient and the expected damage cost was enormously reduced because of the application of isolation, which leaded to the reduction of the LCC of the tank.