Numerical Investigation of Thermal Energy Storage in Light Walls Integrated with Phase Change Materials in Hot Climates

Authors:

Abstract
Building walls usually are composed of multiple layers to mitigate external environmental effects. However, their performance can be further improved through the integration of Thermal Energy Storage (TES) strategies. Incorporating Phase Change Materials (PCMs) into wall assemblies as an additional layer facilitates latent heat storage and release, thereby enhancing thermal regulation via successive phase transition cycles, in line with energy-efficient building applications. but reduces usable floor space and limiting its economic viability. This study introduces a design methodology for PCM-integrated walls by proposing five different PCM integrated wall configurations of different numbers and configurations of PCM cavities. The proposed wall configurations provide a framework to enhance storage capacity, support load shifting, and improve thermal regulation especially in the hot summer climatic likes Cairo, Egypt. Numerical investigation is introduced for the five proposed TES wall configurations compared with the reference wall without PCM under different climatic conditions. The influence of TES wall configurations on thermal performance through inner temperature, heat flux, peak temperature reduction and attenuation factor, as well as the differential liquid fraction profile, together with the progression of the solid to liquid boundary, were introduced as a novel indicators for assessing melting dynamics and PCM characteristic behavior. The results indicate that TES wall configuration with single PCM cavity represents the optimum thermal storage performance, achieving a 6-hour peak load shift, a 0.9 °C reduction in interior wall temperature, and a 59% decrease in inner heat flux in comparison with the reference wall. Furthermore, this configuration provides the strongest attenuation of temperature fluctuations, with the highest peak temperature reduction of 40.3°C when compared with all other TES wall configurations and the reference wall. In addition, the overall melting period increases as the number of cavities decreases, with configuration with single cavity exhibiting a 40% extension in melting duration. This configuration also reduces the daily energy transfer from 1108.6 to 723.14 W/m², corresponding to an average energy saving of approximately 34.84% relative to the reference wall during the summer season.

This publication has 41 references indexed in Scilit: