Mahmoud Said
Research Subjects
Mahmoud Said has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
S.A. Nada
6 shared publicationsHamdy Hassan
4 shared publicationsW.G. Alshaer
3 shared publications- A. Haggag2 shared publications
- Mohamed Rady
Mechanical Engineering Department, Faculty of Engineering at Rabigh, King Abdulaziz University, Jeddah 21589, Saudi Arabia
2 shared publications R.M. Saleh
2 shared publications
Latest Publications
- Open Access
- 14 March 2026
- Published by Elsevier in SSRN Electronic Journal
Experimental investigation of the heat pump performance based on an oval-tube heat exchanger
Heat pumps are widely favored for their energy efficiency, versatility, and ability to provide both seasonal cooling and heating. However, their performance and environmental impact are largely affected by the refrigerant type and heat exchanger design. In the present study, compact and highly efficient oval-tube heat exchangers (OTHE) are proposed. The proposed OTHE offers volume and mass reduction for the condenser, while providing superior heat transfer characteristics, compared to the conventional fin-tube heat exchangers (FTHE) in heat pumps. An experimental investigation was conducted to evaluate system performance using R410A, R290, and R32 across different refrigerant charges and various capillary lengths using OTHE in a heat pump. Experimental results show that the required refrigerant charge for R410A and R32 was reduced by 13.7 and 44.2%, respectively, while the cooling capacity increased by 4.3 and 4.8%. Notably, utilizing OTHE with R32 had the highest coefficient of performance (COP), outperforming other refrigerants by 8.3%. Furthermore, the consumed power decreased by 2.4%, 7.4%, and 12.9% for R410A, R290, and R32, respectively. Overall, the COP increased by 1.3% for the system using R410A and R32.
- 14 March 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessExperimental investigation of the heat pump performance based on an oval-tube heat exchanger
Heat pumps are widely favored for their energy efficiency, versatility, and ability to provide both seasonal cooling and heating. However, their performance and environmental impact are largely affected by the refrigerant type and heat exchanger design. In the present study, compact and highly efficient oval-tube heat exchangers (OTHE) are proposed. The proposed OTHE offers volume and mass reduction for the condenser, while providing superior heat transfer characteristics, compared to the conventional fin-tube heat exchangers (FTHE) in heat pumps. An experimental investigation was conducted to evaluate system performance using R410A, R290, and R32 across different refrigerant charges and various capillary lengths using OTHE in a heat pump. Experimental results show that the required refrigerant charge for R410A and R32 was reduced by 13.7 and 44.2%, respectively, while the cooling capacity increased by 4.3 and 4.8%. Notably, utilizing OTHE with R32 had the highest coefficient of performance (COP), outperforming other refrigerants by 8.3%. Furthermore, the consumed power decreased by 2.4%, 7.4%, and 12.9% for R410A, R290, and R32, respectively. Overall, the COP increased by 1.3% for the system using R410A and R32.
- Open Access
- 10 February 2026
- Published by Elsevier in SSRN Electronic Journal
Numerical Investigation of Thermal Energy Storage in Light Walls Integrated with Phase Change Materials in Hot Climates
Building walls usually are composed of multiple layers to mitigate external environmental effects. However, their performance can be further improved through the integration of Thermal Energy Storage (TES) strategies. Incorporating Phase Change Materials (PCMs) into wall assemblies as an additional layer facilitates latent heat storage and release, thereby enhancing thermal regulation via successive phase transition cycles, in line with energy-efficient building applications. but reduces usable floor space and limiting its economic viability. This study introduces a design methodology for PCM-integrated walls by proposing five different PCM integrated wall configurations of different numbers and configurations of PCM cavities. The proposed wall configurations provide a framework to enhance storage capacity, support load shifting, and improve thermal regulation especially in the hot summer climatic likes Cairo, Egypt. Numerical investigation is introduced for the five proposed TES wall configurations compared with the reference wall without PCM under different climatic conditions. The influence of TES wall configurations on thermal performance through inner temperature, heat flux, peak temperature reduction and attenuation factor, as well as the differential liquid fraction profile, together with the progression of the solid to liquid boundary, were introduced as a novel indicators for assessing melting dynamics and PCM characteristic behavior. The results indicate that TES wall configuration with single PCM cavity represents the optimum thermal storage performance, achieving a 6-hour peak load shift, a 0.9 °C reduction in interior wall temperature, and a 59% decrease in inner heat flux in comparison with the reference wall. Furthermore, this configuration provides the strongest attenuation of temperature fluctuations, with the highest peak temperature reduction of 40.3°C when compared with all other TES wall configurations and the reference wall. In addition, the overall melting period increases as the number of cavities decreases, with configuration with single cavity exhibiting a 40% extension in melting duration. This configuration also reduces the daily energy transfer from 1108.6 to 723.14 W/m², corresponding to an average energy saving of approximately 34.84% relative to the reference wall during the summer season.
- 10 February 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessNumerical Investigation of Thermal Energy Storage in Light Walls Integrated with Phase Change Materials in Hot Climates
Building walls usually are composed of multiple layers to mitigate external environmental effects. However, their performance can be further improved through the integration of Thermal Energy Storage (TES) strategies. Incorporating Phase Change Materials (PCMs) into wall assemblies as an additional layer facilitates latent heat storage and release, thereby enhancing thermal regulation via successive phase transition cycles, in line with energy-efficient building applications. but reduces usable floor space and limiting its economic viability. This study introduces a design methodology for PCM-integrated walls by proposing five different PCM integrated wall configurations of different numbers and configurations of PCM cavities. The proposed wall configurations provide a framework to enhance storage capacity, support load shifting, and improve thermal regulation especially in the hot summer climatic likes Cairo, Egypt. Numerical investigation is introduced for the five proposed TES wall configurations compared with the reference wall without PCM under different climatic conditions. The influence of TES wall configurations on thermal performance through inner temperature, heat flux, peak temperature reduction and attenuation factor, as well as the differential liquid fraction profile, together with the progression of the solid to liquid boundary, were introduced as a novel indicators for assessing melting dynamics and PCM characteristic behavior. The results indicate that TES wall configuration with single PCM cavity represents the optimum thermal storage performance, achieving a 6-hour peak load shift, a 0.9 °C reduction in interior wall temperature, and a 59% decrease in inner heat flux in comparison with the reference wall. Furthermore, this configuration provides the strongest attenuation of temperature fluctuations, with the highest peak temperature reduction of 40.3°C when compared with all other TES wall configurations and the reference wall. In addition, the overall melting period increases as the number of cavities decreases, with configuration with single cavity exhibiting a 40% extension in melting duration. This configuration also reduces the daily energy transfer from 1108.6 to 723.14 W/m², corresponding to an average energy saving of approximately 34.84% relative to the reference wall during the summer season.
- Open Access
- 20 November 2025
- Published by Elsevier in Results in Engineering
- Vol. 28
Experimental study supported by ANN of new fabricated wall integrated with PCMs for energy saving and temperature uniformity of air-conditioned buildings
- 20 November 2025
- Published by Elsevier in Results in Engineering
- Vol. 28
Open AccessExperimental study supported by ANN of new fabricated wall integrated with PCMs for energy saving and temperature uniformity of air-conditioned buildings
- 1 November 2018
- Published by Elsevier in Applied Energy
- Vol. 230, 1380-1402
Parametric study on the effect of using cold thermal storage energy of phase change material on the performance of air-conditioning unit
- 1 November 2018
- Published by Elsevier in Applied Energy
- Vol. 230, 1380-1402
Parametric study on the effect of using cold thermal storage energy of phase change material on the performance of air-conditioning unit
- 1 September 2018
- Published by Elsevier in Energy Conversion and Management
- Vol. 171, 903-916
Effect of using nanoparticles on the performance of thermal energy storage of phase change material coupled with air-conditioning unit
- 1 September 2018
- Published by Elsevier in Energy Conversion and Management
- Vol. 171, 903-916
Effect of using nanoparticles on the performance of thermal energy storage of phase change material coupled with air-conditioning unit
- 1 August 2018
- Published by Elsevier in Energy and Buildings
- Vol. 173, 353-364
An experimental work on the effect of using new technique of thermal energy storage of phase change material on the performance of air conditioning unit
- 1 August 2018
- Published by Elsevier in Energy and Buildings
- Vol. 173, 353-364
An experimental work on the effect of using new technique of thermal energy storage of phase change material on the performance of air conditioning unit
- 1 February 2018
- Published by Elsevier in Applied Thermal Engineering
- Vol. 131, 295-310
Solutions of thermal performance problems of installing AC outdoor units in buildings light wells using mechanical ventilations
- 1 February 2018
- Published by Elsevier in Applied Thermal Engineering
- Vol. 131, 295-310
Solutions of thermal performance problems of installing AC outdoor units in buildings light wells using mechanical ventilations