Gastric slow‐wave modulation via power‐controlled, irrigated radio‐frequency ablation
Open Access
- 19 July 2024
- journal article
- research article
- Published by Wiley in Neurogastroenterology & Motility
- Vol. 36 (9) , e14873
Abstract
Background: Recently, radio‐frequency ablation has been used to modulate slow‐wave activity in the porcine stomach. Gastric ablation is, however, still in its infancy compared to its history in the cardiac field, and electrophysiological studies have been restricted to temperature‐controlled, non‐irrigated ablation. Power‐controlled, irrigated ablation may improve lesion formation at lower catheter‐tip temperatures that produce the desired localized conduction block.Methods and Results: Power‐controlled, irrigated radio‐frequency ablation was performed on the gastric serosal surface of female weaner pigs (n = 5) in vivo. Three combinations of power (10–15 W) and irrigation settings (2–5 mL min−1) were investigated. A total of 12 linear lesions were created (n = 4 for each combination). Slow waves were recorded before and after ablation using high‐resolution electrical mapping.Key Results: Irrigation maintained catheter‐tip temperature below 50°C. Ablation induced a complete conduction block in 8/12 cases (4/4 for 10 W at 2 mL min−1, 1/4 for 10 W at 5 mL min−1, 3/4 for 15 W at 5 mL min−1). Blocks were characterized by a decrease in signal amplitude at the lesion site, along with changes in slow‐wave propagation patterns, where slow waves terminated at and/or rotated around the edge of the lesion.Conclusions and Inferences: Power‐controlled, irrigated ablation can successfully modulate gastric slow‐wave activity at a reduced catheter‐tip temperature compared to temperature‐controlled, non‐irrigated ablation. Reducing the irrigation rate is more effective than increasing power for blocking slow‐wave activity. These benefits suggest that irrigated ablation is a suitable option for further translation into a clinical intervention for gastric electrophysiology disorders.Keywords
This publication has 52 references indexed in Scilit:
- Power-Controlled, Irrigated Radio-Frequency Ablation of Gastric Tissue: A Biophysical Analysis of Lesion FormationDigestive Diseases and Sciences, 2023
- Effects of Electrode Diameter and Contact Material on Signal Morphology of Gastric Bioelectrical Slow Wave RecordingsAnnals of Biomedical Engineering, 2020
- Spatial Patterns From High-Resolution Electrogastrography Correlate With Severity of Symptoms in Patients With Functional Dyspepsia and GastroparesisClinical Gastroenterology and Hepatology, 2019
- Prospective Multicenter Experience With Cooled Radiofrequency Ablation Using High Impedance Irrigant to Target Deep Myocardial Substrate Refractory to Standard AblationJACC: Clinical Electrophysiology, 2018
- Tissue Processing and Hematoxylin and Eosin Staining2014
- High-resolution Mapping of In Vivo Gastrointestinal Slow Wave Activity Using Flexible Printed Circuit Board Electrodes: Methodology and ValidationAnnals of Biomedical Engineering, 2009
- Mechanisms of Focal Heat Destruction of Liver TumorsJournal of Surgical Research, 2005
- Late recurrent arrhythmias after ablation of atrial fibrillation: Incidence, mechanisms, and treatmentHeart Rhythm, 2004
- A comparison of open irrigated and non-irrigated tip catheter ablation for pulmonary vein isolationEP Europace, 2004
- Recurrence of conduction in accessory atrioventricular connections after initially successful radiofrequency catheter ablationJACC, 1992