Sam Simmonds
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Sam Simmonds has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Timothy Robert Angeli-Gordon
Auckland Bioengineering Institute, University of Auckland, Auckland, New Zealand
6 shared publications - Ashton Matthee
Auckland Bioengineering Institute University of Auckland Auckland New Zealand
4 shared publications - Jarrah M. Dowrick
Auckland Bioengineering Institute, University of Auckland, Auckland, New Zealand
4 shared publications Andrew J. Taberner
Auckland Bioengineering Institute University of Auckland Auckland New Zealand
3 shared publications- Gregory B. Sands
Auckland Bioengineering Institute University of Auckland Auckland New Zealand
2 shared publications Linley A. Nisbet
Auckland Bioengineering Institute University of Auckland Auckland New Zealand
2 shared publications
Latest Publications
- Open Access
- 4 April 2025
- Published by Wiley in Acta Physiologica
- Vol. 241 (5) , e70024
Pharmaceutical prokinetic and surgical interventions have opposing effects on gastroduodenal electromechanical coupling
Improper gastric emptying is implicated in several gastrointestinal disorders and may result from disrupted electromechanical coupling of the gastroduodenal junction (GDJ). Rhythmic “slow waves” and myogenic “spikes” are bioelectrical mechanisms that, alongside neural and hormonal co‐factors, control GDJ motility.Aim: To characterize the electromechanical effects of prokinetic (erythromycin) infusion and truncal vagotomy on pre‐clinical in vivo porcine models.Methods: Following ethical approval, the GDJ was exposed in anesthetized crossbreed weaner pigs (N = 10), and custom high‐resolution electrodes were applied to the serosal surface. An EndoFLIP catheter (Medtronic, USA) was inserted orally and positioned across the pylorus to measure luminal diameter. In all subjects, control periods preceded intravenous infusion of erythromycin. In five of those subjects, truncal vagotomy was performed approximately an hour post‐infusion, before recording was resumed.Results: Compared to control recordings, erythromycin increased contractile amplitude ([2.9 ± 1.1] mm vs. [2.2 ± 0.9] mm; p = 0.002) and was associated with more consistent gastric slow‐wave rhythms and increased amplitude of slow waves and spikes. Surgical vagotomy immediately decreased contractile amplitude ([2.90 ± 1.1] mm vs. [1.2 ± 0.6] mm; p = 0.049) and was associated with reduced slow‐wave amplitude, increased gastric and duodenal slow‐wave frequencies, and decreased spike patch coverage.Conclusions: In conclusion, prokinetics and vagotomy produced opposing effects on GDJ electromechanical coupling and could inform diagnostic and interventional practices for patients with pathophysiological complications of this region.
- 4 April 2025
- Published by Wiley in Acta Physiologica
- Vol. 241 (5) , e70024
Open AccessPharmaceutical prokinetic and surgical interventions have opposing effects on gastroduodenal electromechanical coupling
Improper gastric emptying is implicated in several gastrointestinal disorders and may result from disrupted electromechanical coupling of the gastroduodenal junction (GDJ). Rhythmic “slow waves” and myogenic “spikes” are bioelectrical mechanisms that, alongside neural and hormonal co‐factors, control GDJ motility.Aim: To characterize the electromechanical effects of prokinetic (erythromycin) infusion and truncal vagotomy on pre‐clinical in vivo porcine models.Methods: Following ethical approval, the GDJ was exposed in anesthetized crossbreed weaner pigs (N = 10), and custom high‐resolution electrodes were applied to the serosal surface. An EndoFLIP catheter (Medtronic, USA) was inserted orally and positioned across the pylorus to measure luminal diameter. In all subjects, control periods preceded intravenous infusion of erythromycin. In five of those subjects, truncal vagotomy was performed approximately an hour post‐infusion, before recording was resumed.Results: Compared to control recordings, erythromycin increased contractile amplitude ([2.9 ± 1.1] mm vs. [2.2 ± 0.9] mm; p = 0.002) and was associated with more consistent gastric slow‐wave rhythms and increased amplitude of slow waves and spikes. Surgical vagotomy immediately decreased contractile amplitude ([2.90 ± 1.1] mm vs. [1.2 ± 0.6] mm; p = 0.049) and was associated with reduced slow‐wave amplitude, increased gastric and duodenal slow‐wave frequencies, and decreased spike patch coverage.Conclusions: In conclusion, prokinetics and vagotomy produced opposing effects on GDJ electromechanical coupling and could inform diagnostic and interventional practices for patients with pathophysiological complications of this region.
- Open Access
- 20 February 2025
- Published by Wiley in Acta Physiologica
- Vol. 241 (3) , e70008
Electromechanical coupling across the gastroduodenal junction
The gastroduodenal junction is uniquely capable of regulating digestive functions in the gastrointestinal system. The pyloric sphincter, which demarcates the stomach from the small intestine, acts as a mechanical and electrical barrier, isolating each organ, thus enabling independent behaviors that are critical for proper digestion. Unique electrical patterns in the stomach, pylorus, and duodenum underpin the distinct contractile patterns of these regions, and improper organization of these mechanical behaviors leads to clinical conditions such as gastroparesis and dumping syndrome. For this reason, the gastroduodenal junction should be a focal point in investigations of novel biomarkers of gastrointestinal dysfunction. This review summarizes the current knowledge of bioelectrical and mechanical characteristics of the gastroduodenal junction, as well as the relevant underlying anatomy. As there is limited documentation of physiological recordings from the gastroduodenal junction of humans, inferences are made from animal studies and from measurements taken from other regions of the gastrointestinal tract, where appropriate. We suggest hypotheses on gastroduodenal electromechanical coupling and propose further studies to support or reject these ideas. Improved physiological understanding of this region, and the advent of novel diagnostic and therapeutic tools are crucial aspects for the future of clinical gastrointestinal medicine.
- 20 February 2025
- Published by Wiley in Acta Physiologica
- Vol. 241 (3) , e70008
Open AccessElectromechanical coupling across the gastroduodenal junction
The gastroduodenal junction is uniquely capable of regulating digestive functions in the gastrointestinal system. The pyloric sphincter, which demarcates the stomach from the small intestine, acts as a mechanical and electrical barrier, isolating each organ, thus enabling independent behaviors that are critical for proper digestion. Unique electrical patterns in the stomach, pylorus, and duodenum underpin the distinct contractile patterns of these regions, and improper organization of these mechanical behaviors leads to clinical conditions such as gastroparesis and dumping syndrome. For this reason, the gastroduodenal junction should be a focal point in investigations of novel biomarkers of gastrointestinal dysfunction. This review summarizes the current knowledge of bioelectrical and mechanical characteristics of the gastroduodenal junction, as well as the relevant underlying anatomy. As there is limited documentation of physiological recordings from the gastroduodenal junction of humans, inferences are made from animal studies and from measurements taken from other regions of the gastrointestinal tract, where appropriate. We suggest hypotheses on gastroduodenal electromechanical coupling and propose further studies to support or reject these ideas. Improved physiological understanding of this region, and the advent of novel diagnostic and therapeutic tools are crucial aspects for the future of clinical gastrointestinal medicine.
- Open Access
- 19 July 2024
- Published by Wiley in Neurogastroenterology & Motility
- Vol. 36 (9) , e14873
Gastric slow‐wave modulation via power‐controlled, irrigated radio‐frequency ablation
Background: Recently, radio‐frequency ablation has been used to modulate slow‐wave activity in the porcine stomach. Gastric ablation is, however, still in its infancy compared to its history in the cardiac field, and electrophysiological studies have been restricted to temperature‐controlled, non‐irrigated ablation. Power‐controlled, irrigated ablation may improve lesion formation at lower catheter‐tip temperatures that produce the desired localized conduction block.Methods and Results: Power‐controlled, irrigated radio‐frequency ablation was performed on the gastric serosal surface of female weaner pigs (n = 5) in vivo. Three combinations of power (10–15 W) and irrigation settings (2–5 mL min−1) were investigated. A total of 12 linear lesions were created (n = 4 for each combination). Slow waves were recorded before and after ablation using high‐resolution electrical mapping.Key Results: Irrigation maintained catheter‐tip temperature below 50°C. Ablation induced a complete conduction block in 8/12 cases (4/4 for 10 W at 2 mL min−1, 1/4 for 10 W at 5 mL min−1, 3/4 for 15 W at 5 mL min−1). Blocks were characterized by a decrease in signal amplitude at the lesion site, along with changes in slow‐wave propagation patterns, where slow waves terminated at and/or rotated around the edge of the lesion.Conclusions and Inferences: Power‐controlled, irrigated ablation can successfully modulate gastric slow‐wave activity at a reduced catheter‐tip temperature compared to temperature‐controlled, non‐irrigated ablation. Reducing the irrigation rate is more effective than increasing power for blocking slow‐wave activity. These benefits suggest that irrigated ablation is a suitable option for further translation into a clinical intervention for gastric electrophysiology disorders.
- 19 July 2024
- Published by Wiley in Neurogastroenterology & Motility
- Vol. 36 (9) , e14873
Open AccessGastric slow‐wave modulation via power‐controlled, irrigated radio‐frequency ablation
Background: Recently, radio‐frequency ablation has been used to modulate slow‐wave activity in the porcine stomach. Gastric ablation is, however, still in its infancy compared to its history in the cardiac field, and electrophysiological studies have been restricted to temperature‐controlled, non‐irrigated ablation. Power‐controlled, irrigated ablation may improve lesion formation at lower catheter‐tip temperatures that produce the desired localized conduction block.Methods and Results: Power‐controlled, irrigated radio‐frequency ablation was performed on the gastric serosal surface of female weaner pigs (n = 5) in vivo. Three combinations of power (10–15 W) and irrigation settings (2–5 mL min−1) were investigated. A total of 12 linear lesions were created (n = 4 for each combination). Slow waves were recorded before and after ablation using high‐resolution electrical mapping.Key Results: Irrigation maintained catheter‐tip temperature below 50°C. Ablation induced a complete conduction block in 8/12 cases (4/4 for 10 W at 2 mL min−1, 1/4 for 10 W at 5 mL min−1, 3/4 for 15 W at 5 mL min−1). Blocks were characterized by a decrease in signal amplitude at the lesion site, along with changes in slow‐wave propagation patterns, where slow waves terminated at and/or rotated around the edge of the lesion.Conclusions and Inferences: Power‐controlled, irrigated ablation can successfully modulate gastric slow‐wave activity at a reduced catheter‐tip temperature compared to temperature‐controlled, non‐irrigated ablation. Reducing the irrigation rate is more effective than increasing power for blocking slow‐wave activity. These benefits suggest that irrigated ablation is a suitable option for further translation into a clinical intervention for gastric electrophysiology disorders.
- 1 July 2024
- Published by American Physiological Society in American Journal of Physiology-Gastrointestinal and Liver Physiology
- Vol. 327 (1) , G93-G104
Electromechanical coupling and anatomy of the in vivo gastroduodenal junction
This study applies electrical mapping, impedance planimetry, and histological techniques to the gastroduodenal junction to elucidate electromechanical coupling in vivo. Contractions of the terminal antrum and pyloric sphincter were associated with gastric slow waves. In the duodenum, bursts of spike activity triggered oscillating contractions. The relative sparsity of myenteric interstitial cells of Cajal in the pylorus, compared with the adjacent antrum and duodenum, is hypothesized to prevent coupling between antral and duodenal slow waves.
- 1 July 2024
- Published by American Physiological Society in American Journal of Physiology-Gastrointestinal and Liver Physiology
- Vol. 327 (1) , G93-G104
Electromechanical coupling and anatomy of the in vivo gastroduodenal junction
This study applies electrical mapping, impedance planimetry, and histological techniques to the gastroduodenal junction to elucidate electromechanical coupling in vivo. Contractions of the terminal antrum and pyloric sphincter were associated with gastric slow waves. In the duodenum, bursts of spike activity triggered oscillating contractions. The relative sparsity of myenteric interstitial cells of Cajal in the pylorus, compared with the adjacent antrum and duodenum, is hypothesized to prevent coupling between antral and duodenal slow waves.
- 16 November 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 71 (4) , 1289-1297
Measurement and Analysis of In Vivo Gastroduodenal Slow Wave Patterns Using Anatomically-Specific Cradles and Electrodes
Objective: Bioelectrical ‘slow waves’ regulate gastrointestinal contractions. We aimed to confirm whether the pyloric sphincter demarcates slow waves in the intact stomach and duodenum. Methods: We developed and validated novel anatomically-specific electrode cradles and analysis techniques which enable high-resolution slow wave mapping across the in vivo gastroduodenal junction. Cradles housed flexible-printed-circuit and custom cradle-specific electrode arrays during acute porcine experiments ( N = 9; 44.92 kg ± 8.49 kg) and maintained electrode contact with the gastroduodenal serosa. Simultaneous gastric and duodenal slow waves were filtered independently after determining suitable organ-specific filters. Validated algorithms calculated slow wave propagation patterns and quantitative descriptions. Results: Butterworth filters, with cut-off frequencies (0.0167 – 2) Hz and (0.167 – 3.33) Hz, were optimal filters for gastric and intestinal slow wave signals, respectively. Antral slow waves had a frequency of (2.76 ± 0.37) cpm, velocity of (4.83 ± 0.21) mm·s -1 , and amplitude of (1.13 ± 0.24) mV, before terminating at the quiescent pylorus that was (46.54 ± 5.73) mm wide. Duodenal slow waves had a frequency of (18.13 ± 0.56) cpm, velocity of (11.66 ± 1.36) mm·s -1 , amplitude of (0.32 ± 0.03) mV, and originated from a pacemaker region (7.24 ± 4.70) mm distal to the quiescent zone. Conclusion: Novel engineering methods enable measurement of in vivo electrical activity across the gastroduodenal junction and provide qualitative and quantitative definitions of slow wave activity. Significance: The pylorus is a clinical target for a range of gastrointestinal motility disorders and this work may inform diagnostic and treatment practices.
- 16 November 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 71 (4) , 1289-1297
Measurement and Analysis of In Vivo Gastroduodenal Slow Wave Patterns Using Anatomically-Specific Cradles and Electrodes
Objective: Bioelectrical ‘slow waves’ regulate gastrointestinal contractions. We aimed to confirm whether the pyloric sphincter demarcates slow waves in the intact stomach and duodenum. Methods: We developed and validated novel anatomically-specific electrode cradles and analysis techniques which enable high-resolution slow wave mapping across the in vivo gastroduodenal junction. Cradles housed flexible-printed-circuit and custom cradle-specific electrode arrays during acute porcine experiments ( N = 9; 44.92 kg ± 8.49 kg) and maintained electrode contact with the gastroduodenal serosa. Simultaneous gastric and duodenal slow waves were filtered independently after determining suitable organ-specific filters. Validated algorithms calculated slow wave propagation patterns and quantitative descriptions. Results: Butterworth filters, with cut-off frequencies (0.0167 – 2) Hz and (0.167 – 3.33) Hz, were optimal filters for gastric and intestinal slow wave signals, respectively. Antral slow waves had a frequency of (2.76 ± 0.37) cpm, velocity of (4.83 ± 0.21) mm·s -1 , and amplitude of (1.13 ± 0.24) mV, before terminating at the quiescent pylorus that was (46.54 ± 5.73) mm wide. Duodenal slow waves had a frequency of (18.13 ± 0.56) cpm, velocity of (11.66 ± 1.36) mm·s -1 , amplitude of (0.32 ± 0.03) mV, and originated from a pacemaker region (7.24 ± 4.70) mm distal to the quiescent zone. Conclusion: Novel engineering methods enable measurement of in vivo electrical activity across the gastroduodenal junction and provide qualitative and quantitative definitions of slow wave activity. Significance: The pylorus is a clinical target for a range of gastrointestinal motility disorders and this work may inform diagnostic and treatment practices.
- Open Access
- 16 August 2023
- Published by Springer Nature in Digestive Diseases and Sciences
- Vol. 68 (10) , 3953-3962
Power-Controlled, Irrigated Radio-Frequency Ablation of Gastric Tissue: A Biophysical Analysis of Lesion Formation
Background Radio-frequency ablation of gastric tissue is in its infancy compared to its extensive history and use in the cardiac field. Aims We employed power-controlled, irrigated radio-frequency ablation to create lesions on the serosal surface of the stomach to examine the impact of ablation power, irrigation, temperature, and impedance on lesion formation and tissue damage. Methods A total of 160 lesions were created in vivo in female weaner pigs (n = 5) using a combination of four power levels (10, 15, 20, 30 W) at two irrigation rates (2, 5 mL min−1) and with one temperature-controlled (65 °C) reference setting previously validated for electrophysiological intervention in the stomach. Results Power and irrigation rate combinations above 15 W resulted in lesions with significantly higher surface area and depth than the temperature-controlled setting. Irrigation resulted in significantly lower temperature (p < 0.001) and impedance (p < 0.001) compared to the temperature-controlled setting. No instances of perforation or tissue pop were recorded for any ablation sequence. Conclusion Power-controlled, irrigated radio-frequency ablation of gastric tissue is effective in creating larger and deeper lesions at reduced temperatures than previously investigated temperature-controlled radio-frequency ablation, highlighting a substantial improvement. These data define the biophysical impact of ablation parameters in gastric tissue, and they will guide future translation toward clinical application and in silico gastric ablation modeling. Graphical Abstract Combination of ablation settings (10–30 W power, 2–5 mL min-1 irrigation) were used to create serosal spot lesions. Histological analysis of lesions quantified localized tissue damage.
- 16 August 2023
- Published by Springer Nature in Digestive Diseases and Sciences
- Vol. 68 (10) , 3953-3962
Open AccessPower-Controlled, Irrigated Radio-Frequency Ablation of Gastric Tissue: A Biophysical Analysis of Lesion Formation
Background Radio-frequency ablation of gastric tissue is in its infancy compared to its extensive history and use in the cardiac field. Aims We employed power-controlled, irrigated radio-frequency ablation to create lesions on the serosal surface of the stomach to examine the impact of ablation power, irrigation, temperature, and impedance on lesion formation and tissue damage. Methods A total of 160 lesions were created in vivo in female weaner pigs (n = 5) using a combination of four power levels (10, 15, 20, 30 W) at two irrigation rates (2, 5 mL min−1) and with one temperature-controlled (65 °C) reference setting previously validated for electrophysiological intervention in the stomach. Results Power and irrigation rate combinations above 15 W resulted in lesions with significantly higher surface area and depth than the temperature-controlled setting. Irrigation resulted in significantly lower temperature (p < 0.001) and impedance (p < 0.001) compared to the temperature-controlled setting. No instances of perforation or tissue pop were recorded for any ablation sequence. Conclusion Power-controlled, irrigated radio-frequency ablation of gastric tissue is effective in creating larger and deeper lesions at reduced temperatures than previously investigated temperature-controlled radio-frequency ablation, highlighting a substantial improvement. These data define the biophysical impact of ablation parameters in gastric tissue, and they will guide future translation toward clinical application and in silico gastric ablation modeling. Graphical Abstract Combination of ablation settings (10–30 W power, 2–5 mL min-1 irrigation) were used to create serosal spot lesions. Histological analysis of lesions quantified localized tissue damage.