R. A. Barrea
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
R. A. Barrea has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
C. Karanfil
Mugla University 2 Physics Department, Faculty of Arts & Sciences Kotekli-Mugla 48187, Turkey
2 shared publicationsD. Gore
The Biophysics Collaborative Access Team (BioCAT), Department of Biological, Chemical and Physical Sciences, Illinois Institute of Technology, Chicago, IL 60616, USA
1 shared publication- Gayle E. Woloschak
Department of Radiation Oncology, Feinberg School of Medicine, Northwestern University, Chicago, USA
1 shared publication - Gregory Robison
Department of Physics and Astronomy, Purdue University, 525 Northwestern Ave., West Lafayette, IN 47907, United States; Department of Physics, Hanover College, Hanover, IN, United States
1 shared publication - Huiying Gu
Department of Neurology, Indiana University School of Medicine, Indianapolis, IN 46202, USA
1 shared publication - Lan Hong
School of Health Sciences, Purdue University, West Lafayette, IN, 47907
1 shared publication
Latest Publications
- 1 September 2012
- Published by Elsevier in Toxicology Letters
- Vol. 213 (2) , 211-219
Increased β-amyloid deposition in Tg-SWDI transgenic mouse brain following in vivo lead exposure
- 1 September 2012
- Published by Elsevier in Toxicology Letters
- Vol. 213 (2) , 211-219
Increased β-amyloid deposition in Tg-SWDI transgenic mouse brain following in vivo lead exposure
- 1 June 2011
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 82 (6) , 063106
High resolution short focal distance Bent Crystal Laue Analyzer for copper K edge x-ray absorption spectroscopy
We have developed a compact short focal distance Bent Crystal Laue Analyzer (BCLA) for Cu speciation studies of biological systems with specific applications to cancer biology. The system provides high energy resolution and high background rejection. The system is composed of an aluminum block serving as a log spiral bender for a 15 micron thick Silicon 111 crystal and a set of soller slits. The energy resolution of the BCLA—about 14 eV at the Cu Kα line— allows resolution of the Cu Kα1 and CuKα2 lines. The system is easily aligned by using a set of motorized XYZ linear stages. Two operation modes are available: incident energy scans (IES) and emission energy scans (EES). IES allows scanning of the incident energy while the BCLA system is maintained at a preselected fixed position—typically CuKα1 line. EES is used when the incident energy is fixed and the analyzer is scanned to provide the peak profile of the emission lines of Cu.
- 1 June 2011
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 82 (6) , 063106
High resolution short focal distance Bent Crystal Laue Analyzer for copper K edge x-ray absorption spectroscopy
We have developed a compact short focal distance Bent Crystal Laue Analyzer (BCLA) for Cu speciation studies of biological systems with specific applications to cancer biology. The system provides high energy resolution and high background rejection. The system is composed of an aluminum block serving as a log spiral bender for a 15 micron thick Silicon 111 crystal and a set of soller slits. The energy resolution of the BCLA—about 14 eV at the Cu Kα line— allows resolution of the Cu Kα1 and CuKα2 lines. The system is easily aligned by using a set of motorized XYZ linear stages. Two operation modes are available: incident energy scans (IES) and emission energy scans (EES). IES allows scanning of the incident energy while the BCLA system is maintained at a preselected fixed position—typically CuKα1 line. EES is used when the incident energy is fixed and the analyzer is scanned to provide the peak profile of the emission lines of Cu.
- 26 May 2010
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 17 (4) , 522-529
Fast-scanning high-flux microprobe for biological X-ray fluorescence microscopy and microXAS
There is a growing interest in the biomedical community in obtaining information concerning the distribution and local chemical environment of metals in tissues and cells. Recently, biological X-ray fluorescence microscopy (XFM) has emerged as the tool of choice to address these questions. A fast-scanning high-flux X-ray microprobe, built around a recently commissioned pair of 200 mm-long Rh-coated silicon Kirkpatrick-Baez mirrors, has been constructed at BioCAT beamline 18ID at the Advanced Photon Source. The new optical system delivers a flux of 1.3 x 10(12) photons s(-1) into a minimum focal spot size of approximately 3-5 microm FWHM. A set of Si drift detectors and bent Laue crystal analyzers may be used in combination with standard ionization chambers for X-ray fluorescence measurements. BioCAT's scanning software allows fast continuous scans to be performed while acquiring and storing full multichannel analyzer spectra per pixel on-the-fly with minimal overhead time (<20 ms per pixel). Together, the high-flux X-ray microbeam and the rapid-scanning capabilities of the BioCAT beamline allow the collection of XFM and micro X-ray absorption spectroscopy (microXAS) measurements from as many as 48 tissue sections per day. This paper reports the commissioning results of the new instrument with representative XFM and microXAS results from tissue samples.
- 26 May 2010
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 17 (4) , 522-529
Fast-scanning high-flux microprobe for biological X-ray fluorescence microscopy and microXAS
There is a growing interest in the biomedical community in obtaining information concerning the distribution and local chemical environment of metals in tissues and cells. Recently, biological X-ray fluorescence microscopy (XFM) has emerged as the tool of choice to address these questions. A fast-scanning high-flux X-ray microprobe, built around a recently commissioned pair of 200 mm-long Rh-coated silicon Kirkpatrick-Baez mirrors, has been constructed at BioCAT beamline 18ID at the Advanced Photon Source. The new optical system delivers a flux of 1.3 x 10(12) photons s(-1) into a minimum focal spot size of approximately 3-5 microm FWHM. A set of Si drift detectors and bent Laue crystal analyzers may be used in combination with standard ionization chambers for X-ray fluorescence measurements. BioCAT's scanning software allows fast continuous scans to be performed while acquiring and storing full multichannel analyzer spectra per pixel on-the-fly with minimal overhead time (<20 ms per pixel). Together, the high-flux X-ray microbeam and the rapid-scanning capabilities of the BioCAT beamline allow the collection of XFM and micro X-ray absorption spectroscopy (microXAS) measurements from as many as 48 tissue sections per day. This paper reports the commissioning results of the new instrument with representative XFM and microXAS results from tissue samples.