Abstract
This paper presents a low-complexity, cost-effective digital beamformer architecture for a high-frequency ultrasound imaging system. The proposed beamformer uses a lookup table and linear interpolation methods for computing the dynamic receive focusing delays and a postfiltering technique to minimize hardware complexity. In the postfiltering technique, channel radio-frequency data having the same fractional delay (i.e., 16f0 resolution) are aggregated prior to interpolation. Thus, only four polyphase structure filters are required in the developed beamformer. In addition, a quadrature bandpass filter that generates an analytic signal is utilized as an interpolation filter; this allows decimation during beam formation and a reduction in computational complexity. The proposed method was evaluated through a 20-μm wire phantom experiment, and the -6-dB lateral and axial resolutions obtained therein were measured and compared with those obtained using a conventional method. The same lateral (165 μm) and axial (80 μm) resolutions at a depth of 5.6 mm were obtained using both the methods, and the proposed method could reduce the beamforming points (i.e., computational complexity) by a factor of the decimation factor (≥4). Images from an excised bovine eye were captured; they showed that the proposed beamformer identified fine anatomical structures such as cornea or iris without compromising the spatial resolution and reduced the computational complexity.Keywords
Funding Information
- 2016 Inje University Research Grant
- Ministry of Science, ICT and Future Planning, South Korea, through the ICT Consilience Creative Program supervised by the Institute for Information and communications Technology Promotion (IITP-R0346-16-1007)
This publication has 33 references indexed in Scilit:
- A System-on-Chip Solution for Point-of-Care Ultrasound Imaging Systems: Architecture and ASIC ImplementationIEEE Transactions on Biomedical Circuits and Systems, 2015
- An FPGA-based open platform for ultrasound biomicroscopyIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 2012
- A high-frequency linear ultrasonic array utilizing an interdigitally bonded 2-2 piezo-compositeIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 2011
- Software Beamforming: Comparison between a Phased Array and Synthetic Transmit ApertureUltrasonic Imaging, 2011
- A New 15–50 MHz Array-Based Micro-Ultrasound Scanner for Preclinical ImagingUltrasound in Medicine & Biology, 2009
- Low-cost, high-speed back-end processing system for high-frequency ultrasound B-mode imagingIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 2009
- In Vivo Cardiac Imaging of Adult Zebrafish Using High Frequency Ultrasound (45-75 MHz)Ultrasound in Medicine & Biology, 2008
- Development of a real-time, high-frequency ultrasound digital beamformer for high-frequency linear array transducersIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 2006
- Ultrasound Processing and Computing: Review and Future DirectionsAnnual Review of Biomedical Engineering, 1999
- Analytic signal generation-tips and trapsIEEE Transactions on Signal Processing, 1994