A high-frequency linear ultrasonic array utilizing an interdigitally bonded 2-2 piezo-composite
- 10 October 2011
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 58 (10) , 2202-2212
Abstract
This paper describes the development of a high-frequency 256-element linear ultrasonic array utilizing an interdigitally bonded (IB) piezo-composite. Several IB composites were fabricated with different commercial and experimental piezoelectric ceramics and evaluated to determine a suitable formulation for use in high-frequency linear arrays. It was found that the fabricated fine-scale 2-2 IB composites outperformed 1-3 IB composites with identical pillar- and kerf-widths. This result was not expected and lead to the conclusion that dicing damage was likely the cause of the discrepancy. Ultimately, a 2-2 composite fabricated using a fine-grain piezoelectric ceramic was chosen for the array. The composite was manufactured using one IB operation in the azimuth direction to produce approximately 19-μm-wide pillars separated by 6-μm-wide kerfs. The array had a 50 μm (one wavelength in water) azimuth pitch, two matching layers, and 2 mm elevation length focused to 7.3 mm using a polymethylpentene (TPX) lens. The measured pulse-echo center frequency for a representative array element was 28 MHz and -6-dB bandwidth was 61%. The measured single-element transmit -6-dB directivity was estimated to be 50°. The measured insertion loss was 19 dB after compensating for the effects of attenuation and diffraction in the water bath. A fine-wire phantom was used to assess the lateral and axial resolution of the array when paired with a prototype system utilizing a 64-channel analog beamformer. The -6-dB lateral and axial resolutions were estimated to be 125 and 68 μm, respectively. An anechoic cyst phantom was also imaged to determine the minimum detectable spherical inclusion, and thus the 3-D resolution of the array and beamformer. The minimum anechoic cyst detected was approximately 300 μm in diameter.Keywords
This publication has 23 references indexed in Scilit:
- A high-frequency annular-array transducer using an interdigital bonded 1-3 compositeIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 2011
- Anechoic sphere phantoms for estimating 3-D resolution of very-high-frequency ultrasound scannersIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 2010
- A New 15–50 MHz Array-Based Micro-Ultrasound Scanner for Preclinical ImagingUltrasound in Medicine & Biology, 2009
- Sidelobe suppression in ultrasound imaging using dual apodization with cross-correlationIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 2008
- Performance and Characterization of New Micromachined High-Frequency Linear ArraysIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 2006
- Operational verification of a 40-MHz annular array transducerIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 2006
- Development of a 35-MHz piezo-composite ultrasound array for medical imagingIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 2006
- Net-shape ceramic processing as a route to ultrafine scale 1-3 connectivity piezoelectric ceramic-polymer composite transducers2005
- Design and Fabrication of Ultrafine Piezoelectric CompositesUltrasonic Imaging, 2005
- Single crystal PZN/PT-polymer composites for ultrasound transducer applicationsIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 2000