Abstract
BACKGROUND: Aluminium‐based drinking water treatment residual (Al‐DWTR) has been used as an emergent substrate in laboratory‐scale and pilot‐scale biofiltration systems (biofilters and constructed wetlands) for its good affinity for phosphorus (P) adsorption. However, there is a concern about whether the P adsorption process will contribute to substrate clogging. Two laboratory‐scale up‐flow biofiltration systems were set up to identify the contribution of the P adsorption process to clogging under various operation conditions.RESULTS: Contributions of individual processes to clogging from biosolids production (SBS), inert matter generated from the conversion of residual biomass (SIS), P adsorption (SP) and inert matter production from influent total suspended solids (SSS) during operation of the two systems were assessed. After 262 days of operation, results indicated that SBS contributed most (53.16 ± 7.73%) to the clogging, followed by SSS (41.48 ± 8.02%), SP (3.14 ± 0.06%) and SIS (2.20 ± 0.27%) when treating the influent with concentrations of 284–558 mg L−1 for COD, 54–197 mg L−1 for SS and 5–13 mg L−1 for P.CONCLUSIONS: The minor contribution of the P adsorption process to substrate clogging further suggests that dewatered Al‐DWTR with a high P removal capacity is a promising substrate for use in biofiltration systems. © 2020 Society of Chemical Industry (SCI)