Determination of the human spine curve based on laser triangulation
Open Access
- 5 February 2015
- journal article
- research article
- Published by Springer Nature in BMC Medical Imaging
- Vol. 15 (1) , 1-11
Abstract
The main objective of the present method was to automatically obtain a spatial curve of the thoracic and lumbar spine based on a 3D shape measurement of a human torso with developed scoliosis. Manual determination of the spine curve, which was based on palpation of the thoracic and lumbar spinous processes, was found to be an appropriate way to validate the method. Therefore a new, noninvasive, optical 3D method for human torso evaluation in medical practice is introduced. Twenty-four patients with confirmed clinical diagnosis of scoliosis were scanned using a specially developed 3D laser profilometer. The measuring principle of the system is based on laser triangulation with one-laser-plane illumination. The measurement took approximately 10 seconds at 700 mm of the longitudinal translation along the back. The single point measurement accuracy was 0.1 mm. Computer analysis of the measured surface returned two 3D curves. The first curve was determined by manual marking (manual curve), and the second was determined by detecting surface curvature extremes (automatic curve). The manual and automatic curve comparison was given as the root mean square deviation (RMSD) for each patient. The intra-operator study involved assessing 20 successive measurements of the same person, and the inter-operator study involved assessing measurements from 8 operators. The results obtained for the 24 patients showed that the typical RMSD between the manual and automatic curve was 5.0 mm in the frontal plane and 1.0 mm in the sagittal plane, which is a good result compared with palpatory accuracy (9.8 mm). The intra-operator repeatability of the presented method in the frontal and sagittal planes was 0.45 mm and 0.06 mm, respectively. The inter-operator repeatability assessment shows that that the presented method is invariant to the operator of the computer program with the presented method. The main novelty of the presented paper is the development of a new, non-contact method that provides a quick, precise and non-invasive way to determine the spatial spine curve for patients with developed scoliosis and the validation of the presented method using the palpation of the spinous processes, where no harmful ionizing radiation is present.Keywords
This publication has 32 references indexed in Scilit:
- Characterization of the head-to-trunk orientation with handheld optical 3D apparatus based on the fringe projection techniqueBioMedical Engineering OnLine, 2013
- ScolioMedIS: Web-oriented information system for idiopathic scoliosis visualization and monitoringComputer Methods and Programs in Biomedicine, 2012
- Manual palpation of lumbo-pelvic landmarks: A validity studyManual Therapy, 2012
- Spinous process morphology: the effect of ageing through adulthood on spinous process size and relationship to sagittal alignmentEuropean Spine Journal, 2011
- Treatment of Thoracic ScoliosisSpine, 2009
- Multiple Diagnostic X-rays for Spine Deformities and Risk of Breast CancerCancer Epidemiology, Biomarkers & Prevention, 2008
- Palpation identification of spinous processes in the lumbar spineManual Therapy, 2007
- Comparing a Supine Radiologic Versus Standing Clinical Measurement of Kyphosis in Older Women: The Fracture Intervention TrialSpine, 2006
- Prediction of anterior scoliotic spinal curve from trunk surface using support vector regressionEngineering Applications of Artificial Intelligence, 2005
- Spinal Sagittal Configuration and Mobility Related to Low-Back Pain in the Female GymnastSpine, 1989