Temperature peaking at beginning of breakdown in 2.45 GHz pulsed off-resonance electron cyclotron resonance ion source hydrogen plasma
- 1 October 2012
- journal article
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 83 (10) , 103302
Abstract
An experimental study of temperature and density evolution during breakdown in off-resonance ECR hydrogen plasma is presented. Under square 2.45 GHz microwave excitation pulses with a frequency of 50 Hz and relative high microwave power, unexpected transient temperature peaks that reach 18 eV during 20 μs are reported at very beginning of plasma breakdown. Decays of such peaks reach final stable temperatures of 5 eV at flat top microwave excitation pulse. Evidence of interplay between incoming power and duty cycle giving different kind of plasma parameters evolutions engaged to microwave coupling times is observed. Under relative high power conditions where short microwave coupling times are recorded, high temperature peaks are measured. However, for lower incoming powers and longer coupling times, temperature evolves gradually to a higher final temperature without peaking. On the other hand, the early instant where temperature peaks are observed also suggest a possible connection with preglow processes during breakdown in ECRIS plasmas.Keywords
This publication has 9 references indexed in Scilit:
- Review on high current 2.45 GHz electron cyclotron resonance sources (invited)Review of Scientific Instruments, 2010
- The role of seed electrons on the plasma breakdown and preglow of electron cyclotron resonance ion sourceReview of Scientific Instruments, 2010
- Plasma breakdown diagnostics with the biased disc of electron cyclotron resonance ion sourcePlasma Sources Science and Technology, 2009
- Study of pulsed electron cyclotron resonance ion source plasma near breakdown: The preglowReview of Scientific Instruments, 2008
- Understanding Langmuir probe current-voltage characteristicsAmerican Journal of Physics, 2007
- Plasma-based ion implantation and deposition: a review of physics, technology, and applicationsIEEE Transactions on Plasma Science, 2005
- Using Langmuir probes to measure the plasma decay rates in pulsed RF magnetron dischargesJournal of Physics D: Applied Physics, 2001
- The accuracy of Langmuir probe ion density measurements in low-frequency RF dischargesPlasma Sources Science and Technology, 1996
- Some particular aspects of the physics of the ECR sources for multicharged ionsReview of Scientific Instruments, 1990