Dynamic correction for parallel conductance, GP, and gain factor, α, in invasive murine left ventricular volume measurements
Authors:
- 1 December 2009
- journal article
- Published by American Physiological Society in Journal of Applied Physiology
- Vol. 107 (6) , 1693-1703
Abstract
The conductance catheter technique could be improved by determining instantaneous parallel conductance (GP), which is known to be time varying, and by including a time-varying calibration factor in Baan's equation [α( t)]. We have recently proposed solutions to the problems of both time-varying GP and time-varying α, which we term “admittance” and “Wei's equation,” respectively. We validate both our solutions in mice, compared with the currently accepted methods of hypertonic saline (HS) to determine GP and Baan's equation calibrated with both stroke volume (SV) and cuvette. We performed simultaneous echocardiography in closed-chest mice ( n = 8) as a reference for left ventricular (LV) volume and demonstrate that an off-center position for the miniaturized pressure-volume (PV) catheter in the LV generates end-systolic and diastolic volumes calculated by admittance with less error ( P < 0.03) (−2.49 ± 15.33 μl error) compared with those same parameters calculated by SV calibrated conductance (35.89 ± 73.22 μl error) and by cuvette calibrated conductance (−7.53 ± 16.23 μl ES and −29.10 ± 31.53 μl ED error). To utilize the admittance approach, myocardial permittivity (εm) and conductivity (σm) were calculated in additional mice ( n = 7), and those results are used in this calculation. In aortic banded mice ( n = 6), increased myocardial permittivity was measured (11,844 ± 2,700 control, 21,267 ± 8,005 banded, P < 0.05), demonstrating that muscle properties vary with disease state. Volume error calculated with respect to echo did not significantly change in aortic banded mice (6.74 ± 13.06 μl, P = not significant). Increased inotropy in response to intravenous dobutamine was detected with greater sensitivity with the admittance technique compared with traditional conductance [4.9 ± 1.4 to 12.5 ± 6.6 mmHg/μl Wei's equation ( P < 0.05), 3.3 ± 1.2 to 8.8 ± 5.1 mmHg/μl using Baan's equation ( P = not significant)]. New theory and method for instantaneous GP removal, as well as application of Wei's equation, are presented and validated in vivo in mice. We conclude that, for closed-chest mice, admittance (dynamic GP) and Wei's equation (dynamic α) provide more accurate volumes than traditional conductance, are more sensitive to inotropic changes, eliminate the need for hypertonic saline, and can be accurately extended to aortic banded mice.Keywords
This publication has 30 references indexed in Scilit:
- Measurement of cardiac function using pressure–volume conductance catheter technique in mice and ratsNature Protocols, 2008
- Left ventricular volume measurement in mice by conductance catheter: evaluation and optimization of calibrationAmerican Journal of Physiology-Heart and Circulatory Physiology, 2007
- Magnetic resonance imaging of progressive cardiomyopathic changes in the db/db mouseAmerican Journal of Physiology-Heart and Circulatory Physiology, 2007
- Role of diastolic properties in the transition to failure in a mouse model of the cardiac dilatationAmerican Journal of Physiology-Heart and Circulatory Physiology, 2006
- Hemodynamic profile, responsiveness to anandamide, and baroreflex sensitivity of mice lacking fatty acid amide hydrolaseAmerican Journal of Physiology-Heart and Circulatory Physiology, 2005
- Simulated microgravity produces attenuated baroreflex-mediated pressor, chronotropic, and inotropic responses in miceAmerican Journal of Physiology-Heart and Circulatory Physiology, 2005
- A self-calibrating telemetry system for measurement of ventricular pressure-volume relations in conscious, freely moving ratsAmerican Journal of Physiology-Heart and Circulatory Physiology, 2004
- Right ventricular volume measurement: can conductance do it better?Physiological Measurement, 2000
- The four-electrode resistivity technique in anisotropic media: theoretical analysis and application on myocardial tissue in vivoIEEE Transactions on Biomedical Engineering, 1993
- Continuous measurement of left ventricular volume in animals and humans by conductance catheter.Circulation, 1984