In vivo myograph measurement of muscle contraction at optimal length
Open Access
- 1 January 2007
- journal article
- research article
- Published by Springer Nature in BioMedical Engineering OnLine
- Vol. 6 (1) , 1
Abstract
Current devices for measuring muscle contraction in vivo have limited accuracy in establishing and re-establishing the optimum muscle length. They are variable in the reproducibility to determine the muscle contraction at this length, and often do not maintain precise conditions during the examination. Consequently, for clinical testing only semi-quantitative methods have been used. We present a newly developed myograph, an accurate measuring device for muscle contraction, consisting of three elements. Firstly, an element for adjusting the axle of the device and the physiological axis of muscle contraction; secondly, an element to accurately position and reposition the extremity of the muscle; and thirdly, an element for the progressive pre-stretching and isometric locking of the target muscle. Thus it is possible to examine individual in vivo muscles in every pre-stretched, specified position, to maintain constant muscle-length conditions, and to accurately re-establish the conditions of the measurement process at later sessions. In a sequence of experiments the force of contraction of the muscle at differing stretching lengths were recorded and the forces determined. The optimum muscle length for maximal force of contraction was established. In a following sequence of experiments with smaller graduations around this optimal stretching length an increasingly accurate optimum muscle length for maximal force of contraction was determined. This optimum length was also accurately re-established at later sessions. We have introduced a new technical solution for valid, reproducible in vivo force measurements on every possible point of the stretching curve. Thus it should be possible to study the muscle contraction in vivo to the same level of accuracy as is achieved in tests with in vitro organ preparations.Keywords
This publication has 32 references indexed in Scilit:
- EMG Changes in Human Thenar Motor Units With Force Potentiation and FatigueJournal of Neurophysiology, 2006
- A new method for measuring passive length–tension properties of human gastrocnemius muscle in vivoJournal of Biomechanics, 2005
- Measurement and reproducibility of strength and voluntary activation of lower‐limb musclesMuscle & Nerve, 2004
- Phonomyography and Mechanomyography Can Be Used Interchangeably to Measure Neuromuscular Block at the Adductor Pollicis MuscleAnesthesia & Analgesia, 2004
- Re‐Evaluation of Muscle Wisdom in the Human Adductor Pollicis using Physiological Rates of StimulationThe Journal of Physiology, 2003
- Force enhancement following muscle stretch of electrically stimulated and voluntarily activated human adductor pollicisThe Journal of Physiology, 2002
- Motor unit behaviour and contractile changes during fatigue in the human first dorsal interosseusThe Journal of Physiology, 2001
- Comparison of contractile properties of single motor units in human intrinsic and extrinsic finger musclesThe Journal of Physiology, 2000
- Accuracy, reproducibility, and variability of hand-held dynamometry in motor neuron disease.Journal of Neurology, Neurosurgery & Psychiatry, 1994
- Microcomputer system for the analysis of muscle functionJournal of Biomedical Engineering, 1987