Michael Winterhalter
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Michael Winterhalter has a total of 67 co-authors. Here are the top co-authors by number of shared publications:
S. Piepenbrock
11 shared publications- Niels Rahe-Meyer
Department of Anaesthesiology, Hannover Medical School, Hannover, Germany
10 shared publications J. Zuk
Hannover Medical School, Department of Anesthesiology, Hannover, Germany
6 shared publicationsC. Hagl
4 shared publicationsH. Hecker
4 shared publicationsC. Gras
Department of Anesthesiology
3 shared publications
Latest Publications
- 1 April 2008
- Published by Wolters Kluwer Health in European Journal of Anaesthesiology
- Vol. 25 (4) , 326-335
Endocrine stress response and inflammatory activation during CABG surgery. A randomized trial comparing remifentanil infusion to intermittent fentanyl
Our aim was to compare a continuous infusion of remifentanil with intermittent boluses of fentanyl as regards the perioperative hormonal stress response and inflammatory activation in coronary artery bypass graft patients under sevoflurane-based anaesthesia. In all, 42 patients undergoing coronary artery bypass grafting with cardiopulmonary bypass were prospectively randomized to a fentanyl group (n = 21, total fentanyl dose 2.6 ± 0.3 mg), or a remifentanil group (n = 21, infusion rate 0.25 μg kg−1 min−1). Haemodynamics, plasma levels of epinephrine, norepinephrine, antidiuretic hormone, adrenocorticotropic hormone, cortisol, complement activation (C3a, C5b-9), interleukin (IL)-6, IL-8 and tumour necrosis factor-α were measured at T1: baseline, T2: intubation, T3: sternotomy, T4: 30 min on cardiopulmonary bypass, T5: end of surgery and T6: 8 h postoperatively. Troponin T and creatine kinase-MB were measured postoperatively. Patients in the remifentanil group were extubated significantly earlier than fentanyl patients (240 ± 182 min vs. 418 ± 212 min, P = 0.006). Stress hormones 30 min after start of cardiopulmonary bypass showed higher values in the fentanyl group compared to the remifentanil group (antidiuretic hormone (ADH): 39.94 ± 30.98 vs. 11.7 ± 22.8 pg mL−1, P = 0.002; adrenocorticotropic hormone: 111.5 ± 116.8 vs. 21.81 ± 24.71 pg mL−1, P = 0.01; cortisol 185 ± 86 vs. 131 ± 82 ng mL−1, P = 0.04). The interleukins were significantly higher at some perioperative time points in the fentanyl group compared to the remifentanil group (tumour necrosis factor: T5: 3.57 vs. 2.37; IL-6: T5: 4.62 vs. 3.73; and IL-8: T5: 4.43 vs. 2.65 and T6: 2.61 vs. 1.13). However, cardiopulmonary bypass times and aortic cross-clamp times were longer in the fentanyl group, which may to some extent account for the differences. The perioperative endocrine stress response was attenuated in patients supplemented with continuous remifentanil infusion as compared to intermittent fentanyl.
- 1 April 2008
- Published by Wolters Kluwer Health in European Journal of Anaesthesiology
- Vol. 25 (4) , 326-335
Endocrine stress response and inflammatory activation during CABG surgery. A randomized trial comparing remifentanil infusion to intermittent fentanyl
Our aim was to compare a continuous infusion of remifentanil with intermittent boluses of fentanyl as regards the perioperative hormonal stress response and inflammatory activation in coronary artery bypass graft patients under sevoflurane-based anaesthesia. In all, 42 patients undergoing coronary artery bypass grafting with cardiopulmonary bypass were prospectively randomized to a fentanyl group (n = 21, total fentanyl dose 2.6 ± 0.3 mg), or a remifentanil group (n = 21, infusion rate 0.25 μg kg−1 min−1). Haemodynamics, plasma levels of epinephrine, norepinephrine, antidiuretic hormone, adrenocorticotropic hormone, cortisol, complement activation (C3a, C5b-9), interleukin (IL)-6, IL-8 and tumour necrosis factor-α were measured at T1: baseline, T2: intubation, T3: sternotomy, T4: 30 min on cardiopulmonary bypass, T5: end of surgery and T6: 8 h postoperatively. Troponin T and creatine kinase-MB were measured postoperatively. Patients in the remifentanil group were extubated significantly earlier than fentanyl patients (240 ± 182 min vs. 418 ± 212 min, P = 0.006). Stress hormones 30 min after start of cardiopulmonary bypass showed higher values in the fentanyl group compared to the remifentanil group (antidiuretic hormone (ADH): 39.94 ± 30.98 vs. 11.7 ± 22.8 pg mL−1, P = 0.002; adrenocorticotropic hormone: 111.5 ± 116.8 vs. 21.81 ± 24.71 pg mL−1, P = 0.01; cortisol 185 ± 86 vs. 131 ± 82 ng mL−1, P = 0.04). The interleukins were significantly higher at some perioperative time points in the fentanyl group compared to the remifentanil group (tumour necrosis factor: T5: 3.57 vs. 2.37; IL-6: T5: 4.62 vs. 3.73; and IL-8: T5: 4.43 vs. 2.65 and T6: 2.61 vs. 1.13). However, cardiopulmonary bypass times and aortic cross-clamp times were longer in the fentanyl group, which may to some extent account for the differences. The perioperative endocrine stress response was attenuated in patients supplemented with continuous remifentanil infusion as compared to intermittent fentanyl.
- Open Access
- 1 January 2008
- Published by Springer Nature in BioMedical Engineering OnLine
- Vol. 7 (1) , 20
Complex myograph allows the examination of complex muscle contractions for the assessment of muscle force, shortening, velocity, and work in vivo
The devices used for in vivo examination of muscle contractions assess only pure force contractions and the so-called isokinetic contractions. In isokinetic experiments, the extremity and its muscle are artificially moved with constant velocity by the measuring device, while a tetanic contraction is induced in the muscle, either by electrical stimulation or by maximal voluntary activation. With these systems, experiments cannot be performed at pre-defined, constant muscle length, single contractions cannot be evaluated individually and the separate examination of the isometric and the isotonic components of single contractions is not possible. The myograph presented in our study has two newly developed technical units, i.e. a). a counterforce unit which can load the muscle with an adjustable, but constant force and b). a length-adjusting unit which allows for both the stretching and the contraction length to be infinitely adjustable independently of one another. The two units support the examination of complex types of contraction and store the counterforce and length-adjusting settings, so that these conditions may be accurately reapplied in later sessions. The measurement examples presented show that the muscle can be brought to every possible pre-stretching length and that single isotonic or complex isometric-isotonic contractions may be performed at every length. The applied forces act during different phases of contraction, resulting into different pre- and after-loads that can be kept constant – uninfluenced by the contraction. Maximal values for force, shortening, velocity and work may be obtained for individual muscles. This offers the possibility to obtain information on the muscle status and to monitor its changes under non-invasive measurement conditions. With the Complex Myograph, the whole spectrum of a muscle's mechanical characteristics may be assessed.
- 1 January 2008
- Published by Springer Nature in BioMedical Engineering OnLine
- Vol. 7 (1) , 20
Open AccessComplex myograph allows the examination of complex muscle contractions for the assessment of muscle force, shortening, velocity, and work in vivo
The devices used for in vivo examination of muscle contractions assess only pure force contractions and the so-called isokinetic contractions. In isokinetic experiments, the extremity and its muscle are artificially moved with constant velocity by the measuring device, while a tetanic contraction is induced in the muscle, either by electrical stimulation or by maximal voluntary activation. With these systems, experiments cannot be performed at pre-defined, constant muscle length, single contractions cannot be evaluated individually and the separate examination of the isometric and the isotonic components of single contractions is not possible. The myograph presented in our study has two newly developed technical units, i.e. a). a counterforce unit which can load the muscle with an adjustable, but constant force and b). a length-adjusting unit which allows for both the stretching and the contraction length to be infinitely adjustable independently of one another. The two units support the examination of complex types of contraction and store the counterforce and length-adjusting settings, so that these conditions may be accurately reapplied in later sessions. The measurement examples presented show that the muscle can be brought to every possible pre-stretching length and that single isotonic or complex isometric-isotonic contractions may be performed at every length. The applied forces act during different phases of contraction, resulting into different pre- and after-loads that can be kept constant – uninfluenced by the contraction. Maximal values for force, shortening, velocity and work may be obtained for individual muscles. This offers the possibility to obtain information on the muscle status and to monitor its changes under non-invasive measurement conditions. With the Complex Myograph, the whole spectrum of a muscle's mechanical characteristics may be assessed.
- 30 November 2007
- Published by Springer Nature in Journal of Clinical Monitoring and Computing
- Vol. 22 (1) , 67-74
Prospective Investigation into the Influence of Various Stressors on Skin Impedance
The control mechanisms during general anesthesia include circulation parameters and vegetative reactions. A possible way to quantify vegetative reactions is to measure the impedance of the skin. An activation of the eccrine sweat glands via sympathetic sudomotor fibers induces a secretion of sweat, which generates a drop in skin impedance. The aim of the present study was to investigate the influence which different stressors and measurement electrodes have upon skin impedance.
- 30 November 2007
- Published by Springer Nature in Journal of Clinical Monitoring and Computing
- Vol. 22 (1) , 67-74
Prospective Investigation into the Influence of Various Stressors on Skin Impedance
The control mechanisms during general anesthesia include circulation parameters and vegetative reactions. A possible way to quantify vegetative reactions is to measure the impedance of the skin. An activation of the eccrine sweat glands via sympathetic sudomotor fibers induces a secretion of sweat, which generates a drop in skin impedance. The aim of the present study was to investigate the influence which different stressors and measurement electrodes have upon skin impedance.
- 1 June 2007
- Published by Wolters Kluwer Health in European Journal of Anaesthesiology
- Vol. 24 (Supplement) , 50
Randomized study comparing iNO and inhaled Iloprost in cardiac surgery
- 1 June 2007
- Published by Wolters Kluwer Health in European Journal of Anaesthesiology
- Vol. 24 (Supplement) , 50
Randomized study comparing iNO and inhaled Iloprost in cardiac surgery
- 1 April 2007
- Published by Springer Nature in Intensivmedizin und Notfallmedizin
- Vol. 44 (3) , 166-177
Endocrine stress response and myocardial outcome under balanced anesthesia with sevoflurane or TIVA with propofol in patients undergoing CABG
- 1 April 2007
- Published by Springer Nature in Intensivmedizin und Notfallmedizin
- Vol. 44 (3) , 166-177
Endocrine stress response and myocardial outcome under balanced anesthesia with sevoflurane or TIVA with propofol in patients undergoing CABG
- Open Access
- 1 January 2007
- Published by Springer Nature in BioMedical Engineering OnLine
- Vol. 6 (1) , 1
In vivo myograph measurement of muscle contraction at optimal length
Current devices for measuring muscle contraction in vivo have limited accuracy in establishing and re-establishing the optimum muscle length. They are variable in the reproducibility to determine the muscle contraction at this length, and often do not maintain precise conditions during the examination. Consequently, for clinical testing only semi-quantitative methods have been used. We present a newly developed myograph, an accurate measuring device for muscle contraction, consisting of three elements. Firstly, an element for adjusting the axle of the device and the physiological axis of muscle contraction; secondly, an element to accurately position and reposition the extremity of the muscle; and thirdly, an element for the progressive pre-stretching and isometric locking of the target muscle. Thus it is possible to examine individual in vivo muscles in every pre-stretched, specified position, to maintain constant muscle-length conditions, and to accurately re-establish the conditions of the measurement process at later sessions. In a sequence of experiments the force of contraction of the muscle at differing stretching lengths were recorded and the forces determined. The optimum muscle length for maximal force of contraction was established. In a following sequence of experiments with smaller graduations around this optimal stretching length an increasingly accurate optimum muscle length for maximal force of contraction was determined. This optimum length was also accurately re-established at later sessions. We have introduced a new technical solution for valid, reproducible in vivo force measurements on every possible point of the stretching curve. Thus it should be possible to study the muscle contraction in vivo to the same level of accuracy as is achieved in tests with in vitro organ preparations.
- 1 January 2007
- Published by Springer Nature in BioMedical Engineering OnLine
- Vol. 6 (1) , 1
Open AccessIn vivo myograph measurement of muscle contraction at optimal length
Current devices for measuring muscle contraction in vivo have limited accuracy in establishing and re-establishing the optimum muscle length. They are variable in the reproducibility to determine the muscle contraction at this length, and often do not maintain precise conditions during the examination. Consequently, for clinical testing only semi-quantitative methods have been used. We present a newly developed myograph, an accurate measuring device for muscle contraction, consisting of three elements. Firstly, an element for adjusting the axle of the device and the physiological axis of muscle contraction; secondly, an element to accurately position and reposition the extremity of the muscle; and thirdly, an element for the progressive pre-stretching and isometric locking of the target muscle. Thus it is possible to examine individual in vivo muscles in every pre-stretched, specified position, to maintain constant muscle-length conditions, and to accurately re-establish the conditions of the measurement process at later sessions. In a sequence of experiments the force of contraction of the muscle at differing stretching lengths were recorded and the forces determined. The optimum muscle length for maximal force of contraction was established. In a following sequence of experiments with smaller graduations around this optimal stretching length an increasingly accurate optimum muscle length for maximal force of contraction was determined. This optimum length was also accurately re-established at later sessions. We have introduced a new technical solution for valid, reproducible in vivo force measurements on every possible point of the stretching curve. Thus it should be possible to study the muscle contraction in vivo to the same level of accuracy as is achieved in tests with in vitro organ preparations.
- Open Access
- 1 January 2007
- Published by Springer Nature in BioMedical Engineering OnLine
- Vol. 6 (1) , 49
Assessment of precision and reproducibility of a new myograph
The physiological characteristics of muscle activity and the assessment of muscle strength represent important diagnostic information. There are many devices that measure muscle force in humans, but some require voluntary contractions, which are difficult to assess in weak or unconscious patients who are unable to complete a full range of voluntary force assessment tasks. Other devices, which obtain standard muscle contractions by electric stimulations, do not have the technology required to induce and measure reproducible valid contractions at the optimum muscle length. In our study we used a newly developed diagnostic device which measures accurately the reproducibility and time-changed-variability of the muscle force in an individual muscle. A total of 500 in-vivo measurements of supra-maximal isometric single twitch contractions were carried out on the musculus adductor pollicis of 5 test subjects over 10 sessions, with ten repetitions per session. The same protocol was performed on 405 test subjects with two repetitions each to determine a reference-interval on healthy subjects. Using our test setting, we found a high reproducibility of the muscle contractions of each test subject. The precision of the measurements performed with our device was 98.74%. Only two consecutive measurements are needed in order to assess a real, representative individual value of muscle force. The mean value of the force of contraction was 9.51 N and the 95% reference interval was 4.77–14.25 N. The new myograph is a highly reliable measuring device with which the adductor pollicis can be investigated at the optimum length. It has the potential to become a reliable and valid tool for diagnostic in the clinical setting and for monitoring neuromuscular diseases.
- 1 January 2007
- Published by Springer Nature in BioMedical Engineering OnLine
- Vol. 6 (1) , 49
Open AccessAssessment of precision and reproducibility of a new myograph
The physiological characteristics of muscle activity and the assessment of muscle strength represent important diagnostic information. There are many devices that measure muscle force in humans, but some require voluntary contractions, which are difficult to assess in weak or unconscious patients who are unable to complete a full range of voluntary force assessment tasks. Other devices, which obtain standard muscle contractions by electric stimulations, do not have the technology required to induce and measure reproducible valid contractions at the optimum muscle length. In our study we used a newly developed diagnostic device which measures accurately the reproducibility and time-changed-variability of the muscle force in an individual muscle. A total of 500 in-vivo measurements of supra-maximal isometric single twitch contractions were carried out on the musculus adductor pollicis of 5 test subjects over 10 sessions, with ten repetitions per session. The same protocol was performed on 405 test subjects with two repetitions each to determine a reference-interval on healthy subjects. Using our test setting, we found a high reproducibility of the muscle contractions of each test subject. The precision of the measurements performed with our device was 98.74%. Only two consecutive measurements are needed in order to assess a real, representative individual value of muscle force. The mean value of the force of contraction was 9.51 N and the 95% reference interval was 4.77–14.25 N. The new myograph is a highly reliable measuring device with which the adductor pollicis can be investigated at the optimum length. It has the potential to become a reliable and valid tool for diagnostic in the clinical setting and for monitoring neuromuscular diseases.
- 1 October 2006
- Published by Elsevier in Journal of Cardiothoracic and Vascular Anesthesia
- Vol. 20 (5) , 716-718
Inhaled Iloprost in Lung Transplantation: Can It Avoid Extracorporeal Circulation in Patients With Severe Pulmonary Hypertension?
- 1 October 2006
- Published by Elsevier in Journal of Cardiothoracic and Vascular Anesthesia
- Vol. 20 (5) , 716-718
Inhaled Iloprost in Lung Transplantation: Can It Avoid Extracorporeal Circulation in Patients With Severe Pulmonary Hypertension?
- 9 February 2006
- Published by Georg Thieme Verlag KG in The Thoracic and Cardiovascular Surgeon
- Vol. 54 (S 1) , PP_57
Cerebral microembolization during antegrade selective cerebral perfusion
Introduction: This study quantified the number of intraoperative microemboli in patients undergoing aortic arch surgery using selective cerebral perfusion (SCP) in comparison with those in patients undergoing ascending aortic replacement without circulatory arrest and SCP. Methods: A transcranial Doppler monitoring of the medial cerebral artery was performed in 15 patients undergoing proximal arch replacement with SCP (SCP group) and 15 patients undergoing replacement of the ascending aorta (Control group). Results: There was no significant difference in the high-intensity transient signals count between the SCP group and the Control group at any phase. In the SCP group, 4.8% of microemboli occurred during crossclamping, and only 0.6% occurred during SCP. In the Control group, 4.6% occurred during crossclamping. Most microemboli occurred after declamping in both groups; 92.2% in the SCP group and 92.1% in the Control group. Conclusion: The present study demonstrated that outbreak frequency of microemboli during SCP was very low, and thus implies that the risk of embolic event which may be caused by SCP is very low.
- 9 February 2006
- Published by Georg Thieme Verlag KG in The Thoracic and Cardiovascular Surgeon
- Vol. 54 (S 1) , PP_57
Cerebral microembolization during antegrade selective cerebral perfusion
Introduction: This study quantified the number of intraoperative microemboli in patients undergoing aortic arch surgery using selective cerebral perfusion (SCP) in comparison with those in patients undergoing ascending aortic replacement without circulatory arrest and SCP. Methods: A transcranial Doppler monitoring of the medial cerebral artery was performed in 15 patients undergoing proximal arch replacement with SCP (SCP group) and 15 patients undergoing replacement of the ascending aorta (Control group). Results: There was no significant difference in the high-intensity transient signals count between the SCP group and the Control group at any phase. In the SCP group, 4.8% of microemboli occurred during crossclamping, and only 0.6% occurred during SCP. In the Control group, 4.6% occurred during crossclamping. Most microemboli occurred after declamping in both groups; 92.2% in the SCP group and 92.1% in the Control group. Conclusion: The present study demonstrated that outbreak frequency of microemboli during SCP was very low, and thus implies that the risk of embolic event which may be caused by SCP is very low.