Assessment of the Use of Multi-Channel Organic Electrodes to Record ENG on Small Nerves: Application to Phrenic Nerve Burst Detection
Authors:
- Yvan AvdeewYAYvan Avdeew
- Victor Bergé-LavalVBVictor Bergé-Laval
- Virginie Le RolleVRVirginie Le Rolle
- Gabriel DieusetGDGabriel Dieuset
- David MoreauDMDavid Moreau
- Loïg KergoatLKLoïg Kergoat
- Benoît MartinBMBenoît Martin
- Christophe BernardCBChristophe Bernard
- Christian GestreauChristian Gestreau
- Alfredo HernándezAHAlfredo Hernández
Open Access
Abstract
Effective closed-loop neuromodulation relies on the acquisition of appropriate physiological control variables and the delivery of an appropriate stimulation signal. In particular, electroneurogram (ENG) data acquired from a set of electrodes applied at the surface of the nerve may be used as a potential control variable in this field. Improved electrode technologies and data processing methods are clearly needed in this context. In this work, we evaluated a new electrode technology based on multichannel organic electrodes (OE) and applied a signal processing chain in order to detect respiratory-related bursts from the phrenic nerve. Phrenic ENG (pENG) were acquired from nine Long Evans rats in situ preparations. For each preparation, a 16-channel OE was applied around the phrenic nerve’s surface and a suction electrode was applied to the cut end of the same nerve. The former electrode provided input multivariate pENG signals while the latter electrode provided the gold standard for data analysis. Correlations between OE signals and that from the gold standard were estimated. Signal to noise ratio (SNR) and ROC curves were built to quantify phrenic bursts detection performance. Correlation score showed the ability of the OE to record high-quality pENG. Our methods allowed good phrenic bursts detection. However, we failed to demonstrate a spatial selectivity from the multiple pENG recorded with our OE matrix. Altogether, our results suggest that highly flexible and biocompatible multi-channel electrode may represent an interesting alternative to metallic cuff electrodes to perform nerve bursts detection and/or closed-loop neuromodulation.Keywords
Funding Information
- Agence Nationale de la Recherche (ANR-17-CE19-0001)
This publication has 71 references indexed in Scilit:
- TASK-2 Channels Contribute to pH Sensitivity of Retrotrapezoid Nucleus Chemoreceptor NeuronsJournal of Neuroscience, 2013
- In vivo recordings of brain activity using organic transistorsNature Communications, 2013
- A high-performance neural prosthesis enabled by control algorithm designNature Neuroscience, 2012
- Central chemoreceptor modulation of breathing via multipath tuning in medullary ventrolateral respiratory column circuitsJournal of Neurophysiology, 2012
- A transverse intrafascicular multichannel electrode (TIME) to interface with the peripheral nerveBiosensors and Bioelectronics, 2010
- On the identification of sensory information from mixed nerves by using single-channel cuff electrodesJournal of NeuroEngineering and Rehabilitation, 2010
- Fascicular anatomy of human femoral nerve: Implications for neural prostheses using nerve cuff electrodesJournal of Rehabilitation Research and Development, 2009
- Parylene flexible neural probes integrated with microfluidic channelsLab on a Chip, 2005
- Impedimetric immunosensors based on the conjugated polymer PPVBiosensors and Bioelectronics, 2005
- Functionally selective peripheral nerve stimulation with a flat interface nerve electrodeIEEE Transactions on Neural Systems and Rehabilitation Engineering, 2002