David Moreau
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
David Moreau has a total of 38 co-authors. Here are the top co-authors by number of shared publications:
- Rodney Philip O'COnnor
Affiliation Mines Saint-Etienne, Centre CMP, Departement BEL, F - 13541 Gardanne, France
5 shared publications - Davide Reato
Champalimaud Foundation, Lisbon, Portugal
2 shared publications Nathan Dumas
Mines Saint‐Etienne Centre CMP Departement BEL Gardanne F‐13541 France
2 shared publicationsRodney O’cOnnor
Mines Saint-Etienne, Centre CMP, Département BEL, Gardanne, France
2 shared publicationsAlberto Lombardini
Affiliation Institut de Neurosciences de la Timone, UMR 7289, CNRS and Aix Marseille Université, 13005 Marseille, France
1 shared publication- Alberto Lombardini
Aix Marseille University, CNRS UMR 7289, INT (Institut de Neurosciences de la Timone) 6 , Marseille
1 shared publication
Latest Publications
- 2 April 2026
- Published by Agence Bibliographique de l'Enseignement Supérieur
Infrared stimulation of neurons
Stimulation infrarouge de neurones: L’exposition aux radiations laser infrarouge peut être utilisée afin de dépolariser des neurones et stimuler l’activité neuronale. Le mécanisme sous-jacent d’une telle stimulation est supposé résulter d’une interaction photothermique. En effet, l’absorption de la radiation infrarouge par le tissu biologique cible, et l’eau qu’il contient, induit une augmentation de température de manière localisée, qui soit influencerait directement les propriétés membranaires de la cellule soit agirait par le biais de l’activation de canaux ioniques thermo-sensibles. Dans la plupart des cas, l’activité électrique des neurones est mesurée électriquement à l’aide de microélectrodes, mais elle peut également être sondée par le biais de la microscopie de fluorescence faisant intervenir des indicateurs calciques. Dans ce travail, l’impact de l’exposition à la radiation infrarouge sur les signaux calciques de neurones a été étudié dans le but d’éclaircir et de préciser le mécanisme résultant de l’interaction photothermique. Des neurones HT22, issus d’hippocampe de souris, et des cellules U87, issues d’un glioblastome humain, ont été utilisés en tant qu’exemples de cellules électriquement excitables et non excitables respectivement. Afin de mesurer la température et les signaux calciques au niveau cellulaire, les fluorophores Rhodamine B et Fluo-4 ont été employés. Le montage, par conséquent tout optique, pour étudier l’influence de l’exposition infrarouge sur l’activité neurale est donc présenté, ainsi que la démarche scientifique menant à l’identification de l’implication de l’activité de la phospholipase C dans le mécanisme étudié. La possibilité de stimuler l’activité neurale in vivo, dans le cerveau d’une souris, avec une mesure simultanée des signaux calciques, est également démontrée à l’aide de souris transgéniques exprimant le GCaMP6S.
- 2 April 2026
- Published by Agence Bibliographique de l'Enseignement Supérieur
Infrared stimulation of neurons
Stimulation infrarouge de neurones: L’exposition aux radiations laser infrarouge peut être utilisée afin de dépolariser des neurones et stimuler l’activité neuronale. Le mécanisme sous-jacent d’une telle stimulation est supposé résulter d’une interaction photothermique. En effet, l’absorption de la radiation infrarouge par le tissu biologique cible, et l’eau qu’il contient, induit une augmentation de température de manière localisée, qui soit influencerait directement les propriétés membranaires de la cellule soit agirait par le biais de l’activation de canaux ioniques thermo-sensibles. Dans la plupart des cas, l’activité électrique des neurones est mesurée électriquement à l’aide de microélectrodes, mais elle peut également être sondée par le biais de la microscopie de fluorescence faisant intervenir des indicateurs calciques. Dans ce travail, l’impact de l’exposition à la radiation infrarouge sur les signaux calciques de neurones a été étudié dans le but d’éclaircir et de préciser le mécanisme résultant de l’interaction photothermique. Des neurones HT22, issus d’hippocampe de souris, et des cellules U87, issues d’un glioblastome humain, ont été utilisés en tant qu’exemples de cellules électriquement excitables et non excitables respectivement. Afin de mesurer la température et les signaux calciques au niveau cellulaire, les fluorophores Rhodamine B et Fluo-4 ont été employés. Le montage, par conséquent tout optique, pour étudier l’influence de l’exposition infrarouge sur l’activité neurale est donc présenté, ainsi que la démarche scientifique menant à l’identification de l’implication de l’activité de la phospholipase C dans le mécanisme étudié. La possibilité de stimuler l’activité neurale in vivo, dans le cerveau d’une souris, avec une mesure simultanée des signaux calciques, est également démontrée à l’aide de souris transgéniques exprimant le GCaMP6S.
- 21 November 2025
- Published by Wiley in Advanced Healthcare Materials
- Vol. 15 (7) , e03970
A Bioelectric Therapy for Glioblastoma: Stimulating Purinergic Signaling via Pulsed Electric Fields
Glioblastoma is a highly aggressive brain cancer with limited treatment options due to the blood‐brain barrier and the development of acquired chemoresistance. Bioelectric therapies, including pulsed electric field (PEF) treatment, have shown promise in cancer therapy by affecting tumor cells and their microenvironment. This study explores the potential of thin‐film electronics for PEF treatments targeting glioblastoma, with a focus on ATP‐mediated calcium signaling. PEFs applied through bare gold and PEDOT:PSS‐coated electrodes induce a transient increase in intracellular calcium, mediated by mechanisms depending on cell location: electroporation near the electrodes and ATP‐mediated signaling for cells located further away. Luminescence assays reveal that PEFs trigger ATP release into the extracellular space, with higher levels observed with PEDOT:PSS‐coated electrodes, despite reduced electroporation effects. The involvement of ATP‐permeable channels and purinergic receptors in calcium signaling is confirmed by selective channel blockers. These findings suggest that PEFs, even in the absence of cell electroporation, stimulate ATP release, activating purinergic receptors and inducing calcium influx in cells not only near the electrodes. Beyond triggered ATP depletion, ATP may act as a damage‐associated molecular pattern, potentially contributing to immune modulation at the tumor site. This highlights the potential of thin‐film electrodes for non‐invasive electrotherapy in glioblastoma treatment.
- 21 November 2025
- Published by Wiley in Advanced Healthcare Materials
- Vol. 15 (7) , e03970
A Bioelectric Therapy for Glioblastoma: Stimulating Purinergic Signaling via Pulsed Electric Fields
Glioblastoma is a highly aggressive brain cancer with limited treatment options due to the blood‐brain barrier and the development of acquired chemoresistance. Bioelectric therapies, including pulsed electric field (PEF) treatment, have shown promise in cancer therapy by affecting tumor cells and their microenvironment. This study explores the potential of thin‐film electronics for PEF treatments targeting glioblastoma, with a focus on ATP‐mediated calcium signaling. PEFs applied through bare gold and PEDOT:PSS‐coated electrodes induce a transient increase in intracellular calcium, mediated by mechanisms depending on cell location: electroporation near the electrodes and ATP‐mediated signaling for cells located further away. Luminescence assays reveal that PEFs trigger ATP release into the extracellular space, with higher levels observed with PEDOT:PSS‐coated electrodes, despite reduced electroporation effects. The involvement of ATP‐permeable channels and purinergic receptors in calcium signaling is confirmed by selective channel blockers. These findings suggest that PEFs, even in the absence of cell electroporation, stimulate ATP release, activating purinergic receptors and inducing calcium influx in cells not only near the electrodes. Beyond triggered ATP depletion, ATP may act as a damage‐associated molecular pattern, potentially contributing to immune modulation at the tumor site. This highlights the potential of thin‐film electrodes for non‐invasive electrotherapy in glioblastoma treatment.
- Open Access
- 1 April 2025
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 20 (4) , e0320376
Inkjet-printed transparent electrodes: Design, characterization, and initial in vivo evaluation for brain stimulation
Electrical stimulation is a powerful tool for investigating and modulating brain activity, as well as for treating neurological disorders. However, understanding the precise effects of electrical stimulation on neural activity has been hindered by limitations in recording neuronal responses near the stimulating electrode, such as stimulation artifacts in electrophysiology or obstruction of the field of view in imaging. In this study, we introduce a novel stimulation device fabricated from conductive polymers that is transparent and therefore compatible with optical imaging techniques. The device is manufactured using a combination of microfabrication and inkjet printing techniques and is flexible, allowing better adherence to the brain’s natural curvature. We characterized the electrical and optical properties of the electrodes, focusing on the trade-off between the maximum current that can be delivered and optical transmittance. We found that a 1 mm diameter, 350 nm thick PEDOT:PSS electrode could be used to apply a maximum current of 130 μA while maintaining 84% transmittance (approximately 50% under 2-photon imaging conditions). We then evaluated the electrode performance in the brain of an anesthetized mouse by measuring the electric field with a nearby recording electrode and found values up to 30 V/m. Finally, we combined experimental data with a finite-element model of the in vivo experimental setup to estimate the distribution of the electric field underneath the electrode in the mouse brain. Our findings indicate that the device can generate an electric field as high as 300 V/m directly beneath the electrode, demonstrating its potential for studying and manipulating neural activity using a range of electrical stimulation techniques relevant to human applications. Overall, this work presents a promising approach for developing versatile new tools to apply and study electrical brain stimulation.
- 1 April 2025
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 20 (4) , e0320376
Open AccessInkjet-printed transparent electrodes: Design, characterization, and initial in vivo evaluation for brain stimulation
Electrical stimulation is a powerful tool for investigating and modulating brain activity, as well as for treating neurological disorders. However, understanding the precise effects of electrical stimulation on neural activity has been hindered by limitations in recording neuronal responses near the stimulating electrode, such as stimulation artifacts in electrophysiology or obstruction of the field of view in imaging. In this study, we introduce a novel stimulation device fabricated from conductive polymers that is transparent and therefore compatible with optical imaging techniques. The device is manufactured using a combination of microfabrication and inkjet printing techniques and is flexible, allowing better adherence to the brain’s natural curvature. We characterized the electrical and optical properties of the electrodes, focusing on the trade-off between the maximum current that can be delivered and optical transmittance. We found that a 1 mm diameter, 350 nm thick PEDOT:PSS electrode could be used to apply a maximum current of 130 μA while maintaining 84% transmittance (approximately 50% under 2-photon imaging conditions). We then evaluated the electrode performance in the brain of an anesthetized mouse by measuring the electric field with a nearby recording electrode and found values up to 30 V/m. Finally, we combined experimental data with a finite-element model of the in vivo experimental setup to estimate the distribution of the electric field underneath the electrode in the mouse brain. Our findings indicate that the device can generate an electric field as high as 300 V/m directly beneath the electrode, demonstrating its potential for studying and manipulating neural activity using a range of electrical stimulation techniques relevant to human applications. Overall, this work presents a promising approach for developing versatile new tools to apply and study electrical brain stimulation.
- Open Access
A Flexible, Implantable, Bioelectronic Electroporation Device for Targeted Ablation of Seizure Foci in the Mouse Brain
The primary method of treatment for patients suffering from drug-resistant focal-onset epilepsy is resective surgery, which adversely impacts neurocognitive function. Radio frequency (RF) ablation and laser ablation are the methods with the most promise, achieving seizure-free rates similar to resection but with less negative impact on neurocognitive function. However, there remains a number of concerns and open technical questions about these two methods of thermal ablation, with the primary ones: (1) heating; (2) hemorrhage and bleeding; and (3) poor directionality. Irreversible electroporation (IRE) is a proven method of focal ablation, which circumvents all three of the primary concerns regarding focal RF and laser ablation. Here, we demonstrate the in vivo application of a flexible implant with organic electrodes for focal ablation of epilepsy foci using high-frequency IRE (H-FIRE) in mice. Our results show that local, targeted ablation is possible in the close neighborhood of the electrode, paving the way for the clinical application in the treatment of focal epilepsy.
Open AccessA Flexible, Implantable, Bioelectronic Electroporation Device for Targeted Ablation of Seizure Foci in the Mouse Brain
The primary method of treatment for patients suffering from drug-resistant focal-onset epilepsy is resective surgery, which adversely impacts neurocognitive function. Radio frequency (RF) ablation and laser ablation are the methods with the most promise, achieving seizure-free rates similar to resection but with less negative impact on neurocognitive function. However, there remains a number of concerns and open technical questions about these two methods of thermal ablation, with the primary ones: (1) heating; (2) hemorrhage and bleeding; and (3) poor directionality. Irreversible electroporation (IRE) is a proven method of focal ablation, which circumvents all three of the primary concerns regarding focal RF and laser ablation. Here, we demonstrate the in vivo application of a flexible implant with organic electrodes for focal ablation of epilepsy foci using high-frequency IRE (H-FIRE) in mice. Our results show that local, targeted ablation is possible in the close neighborhood of the electrode, paving the way for the clinical application in the treatment of focal epilepsy.
- Open Access
- 27 September 2024
- Published by Springer Nature in Scientific Reports
- Vol. 14 (1) , 1-14
Infrared neuroglial modulation of spinal locomotor networks
Infrared neural stimulation (INS) emerges as a promising tool for stimulating the nervous system by its high spatial precision and absence of the use of exogenous agents into the tissue, which led to the first successful proof of concept in human brain. While neural networks have been the focal point of INS research, this technique is also non cell type specific as it triggers activity in non electrically excitable cells. Despite increasing interest, there remains to demonstrate well defined simultaneous astrocytic and neuronal signals in response to INS. Using calcium imaging, we show that INS has the capacity to initiate calcium signaling in both astrocytes and neurons simultaneously from the rostral lumbar spinal cord, each exhibiting distinct temporal and amplitude characteristics. Importantly, the mechanism underlying infrared-induced neuronal and astrocytic calcium signaling differ, with neuronal activity relying on sodium channels, whereas induced astrocytic signaling is predominantly influenced by extracellular calcium and TRPV4 channels. Furthermore, our findings demonstrate the frequency shift of neuronal calcium oscillations through infrared stimulation. By deepening our understanding in INS fundamentals, this technique holds great promise for advancing neuroscience, deepening our understanding of pathologies, and potentially paving the way for future clinical applications.
- 27 September 2024
- Published by Springer Nature in Scientific Reports
- Vol. 14 (1) , 1-14
Open AccessInfrared neuroglial modulation of spinal locomotor networks
Infrared neural stimulation (INS) emerges as a promising tool for stimulating the nervous system by its high spatial precision and absence of the use of exogenous agents into the tissue, which led to the first successful proof of concept in human brain. While neural networks have been the focal point of INS research, this technique is also non cell type specific as it triggers activity in non electrically excitable cells. Despite increasing interest, there remains to demonstrate well defined simultaneous astrocytic and neuronal signals in response to INS. Using calcium imaging, we show that INS has the capacity to initiate calcium signaling in both astrocytes and neurons simultaneously from the rostral lumbar spinal cord, each exhibiting distinct temporal and amplitude characteristics. Importantly, the mechanism underlying infrared-induced neuronal and astrocytic calcium signaling differ, with neuronal activity relying on sodium channels, whereas induced astrocytic signaling is predominantly influenced by extracellular calcium and TRPV4 channels. Furthermore, our findings demonstrate the frequency shift of neuronal calcium oscillations through infrared stimulation. By deepening our understanding in INS fundamentals, this technique holds great promise for advancing neuroscience, deepening our understanding of pathologies, and potentially paving the way for future clinical applications.
- Open Access
Inkjet-printed transparent electrodes for electrical brain stimulation
Electrical stimulation is a powerful tool for investigating and modulating brain activity, as well as for treating neurological disorders. However, understanding the precise effects of electrical stimulation on neural activity has been hindered by limitations in recording neuronal responses near the stimulating electrode, such as stimulation artifacts in electrophysiology or obstruction of the field of view in imaging. In this study, we introduce a novel stimulation device fabricated from conductive polymers that is transparent and therefore compatible with optical imaging techniques. The device is manufactured using a combination of microfabrication and inkjet printing techniques and is flexible, allowing better adherence to the brain’s natural curvature. We characterized the electrical and optical properties of the electrode and evaluated its performance in the brain of an anesthetized mouse. Furthermore, we combined experimental data with a finite-element model of the in-vivo experimental setup to estimate the maximum electric field that the highly transparent device can generate in the mouse brain. Our findings indicate that the device can generate an electric field as high as 300 V/m, demonstrating its potential for studying and manipulating neural activity using a range of electrical stimulation techniques relevant to human applications. Overall, this work presents a promising approach for developing versatile new tools to apply and study electrical brain stimulation.
Open AccessInkjet-printed transparent electrodes for electrical brain stimulation
Electrical stimulation is a powerful tool for investigating and modulating brain activity, as well as for treating neurological disorders. However, understanding the precise effects of electrical stimulation on neural activity has been hindered by limitations in recording neuronal responses near the stimulating electrode, such as stimulation artifacts in electrophysiology or obstruction of the field of view in imaging. In this study, we introduce a novel stimulation device fabricated from conductive polymers that is transparent and therefore compatible with optical imaging techniques. The device is manufactured using a combination of microfabrication and inkjet printing techniques and is flexible, allowing better adherence to the brain’s natural curvature. We characterized the electrical and optical properties of the electrode and evaluated its performance in the brain of an anesthetized mouse. Furthermore, we combined experimental data with a finite-element model of the in-vivo experimental setup to estimate the maximum electric field that the highly transparent device can generate in the mouse brain. Our findings indicate that the device can generate an electric field as high as 300 V/m, demonstrating its potential for studying and manipulating neural activity using a range of electrical stimulation techniques relevant to human applications. Overall, this work presents a promising approach for developing versatile new tools to apply and study electrical brain stimulation.
- Open Access
Assessment of the Use of Multi-Channel Organic Electrodes to Record ENG on Small Nerves: Application to Phrenic Nerve Burst Detection
Effective closed-loop neuromodulation relies on the acquisition of appropriate physiological control variables and the delivery of an appropriate stimulation signal. In particular, electroneurogram (ENG) data acquired from a set of electrodes applied at the surface of the nerve may be used as a potential control variable in this field. Improved electrode technologies and data processing methods are clearly needed in this context. In this work, we evaluated a new electrode technology based on multichannel organic electrodes (OE) and applied a signal processing chain in order to detect respiratory-related bursts from the phrenic nerve. Phrenic ENG (pENG) were acquired from nine Long Evans rats in situ preparations. For each preparation, a 16-channel OE was applied around the phrenic nerve’s surface and a suction electrode was applied to the cut end of the same nerve. The former electrode provided input multivariate pENG signals while the latter electrode provided the gold standard for data analysis. Correlations between OE signals and that from the gold standard were estimated. Signal to noise ratio (SNR) and ROC curves were built to quantify phrenic bursts detection performance. Correlation score showed the ability of the OE to record high-quality pENG. Our methods allowed good phrenic bursts detection. However, we failed to demonstrate a spatial selectivity from the multiple pENG recorded with our OE matrix. Altogether, our results suggest that highly flexible and biocompatible multi-channel electrode may represent an interesting alternative to metallic cuff electrodes to perform nerve bursts detection and/or closed-loop neuromodulation.
Open AccessAssessment of the Use of Multi-Channel Organic Electrodes to Record ENG on Small Nerves: Application to Phrenic Nerve Burst Detection
Effective closed-loop neuromodulation relies on the acquisition of appropriate physiological control variables and the delivery of an appropriate stimulation signal. In particular, electroneurogram (ENG) data acquired from a set of electrodes applied at the surface of the nerve may be used as a potential control variable in this field. Improved electrode technologies and data processing methods are clearly needed in this context. In this work, we evaluated a new electrode technology based on multichannel organic electrodes (OE) and applied a signal processing chain in order to detect respiratory-related bursts from the phrenic nerve. Phrenic ENG (pENG) were acquired from nine Long Evans rats in situ preparations. For each preparation, a 16-channel OE was applied around the phrenic nerve’s surface and a suction electrode was applied to the cut end of the same nerve. The former electrode provided input multivariate pENG signals while the latter electrode provided the gold standard for data analysis. Correlations between OE signals and that from the gold standard were estimated. Signal to noise ratio (SNR) and ROC curves were built to quantify phrenic bursts detection performance. Correlation score showed the ability of the OE to record high-quality pENG. Our methods allowed good phrenic bursts detection. However, we failed to demonstrate a spatial selectivity from the multiple pENG recorded with our OE matrix. Altogether, our results suggest that highly flexible and biocompatible multi-channel electrode may represent an interesting alternative to metallic cuff electrodes to perform nerve bursts detection and/or closed-loop neuromodulation.
- Open Access
- 7 May 2021
- Published by Springer Nature in Scientific Reports
- Vol. 11 (1) , 1-18
Two-photon GCaMP6f imaging of infrared neural stimulation evoked calcium signals in mouse cortical neurons in vivo
Infrared neural stimulation is a promising tool for stimulating the brain because it can be used to excite with high spatial precision without the need of delivering or inserting any exogenous agent into the tissue. Very few studies have explored its use in the brain, as most investigations have focused on sensory or motor nerve stimulation. Using intravital calcium imaging with the genetically encoded calcium indicator GCaMP6f, here we show that the application of infrared neural stimulation induces intracellular calcium signals in Layer 2/3 neurons in mouse cortex in vivo. The number of neurons exhibiting infrared-induced calcium response as well as the amplitude of those signals are shown to be both increasing with the energy density applied. By studying as well the spatial extent of the stimulation, we show that reproducibility of the stimulation is achieved mainly in the central part of the infrared beam path. Stimulating in vivo at such a degree of precision and without any exogenous chromophores enables multiple applications, from mapping the brain’s connectome to applications in systems neuroscience and the development of new therapeutic tools for investigating the pathological brain.
- 7 May 2021
- Published by Springer Nature in Scientific Reports
- Vol. 11 (1) , 1-18
Open AccessTwo-photon GCaMP6f imaging of infrared neural stimulation evoked calcium signals in mouse cortical neurons in vivo
Infrared neural stimulation is a promising tool for stimulating the brain because it can be used to excite with high spatial precision without the need of delivering or inserting any exogenous agent into the tissue. Very few studies have explored its use in the brain, as most investigations have focused on sensory or motor nerve stimulation. Using intravital calcium imaging with the genetically encoded calcium indicator GCaMP6f, here we show that the application of infrared neural stimulation induces intracellular calcium signals in Layer 2/3 neurons in mouse cortex in vivo. The number of neurons exhibiting infrared-induced calcium response as well as the amplitude of those signals are shown to be both increasing with the energy density applied. By studying as well the spatial extent of the stimulation, we show that reproducibility of the stimulation is achieved mainly in the central part of the infrared beam path. Stimulating in vivo at such a degree of precision and without any exogenous chromophores enables multiple applications, from mapping the brain’s connectome to applications in systems neuroscience and the development of new therapeutic tools for investigating the pathological brain.
- 9 August 2017
- Published by Wiley in Journal of Biophotonics
- Vol. 11 (2)
Infrared neural stimulation induces intracellular Ca2+ release mediated by phospholipase C
The influence of infrared laser pulses on intracellular Ca2+ signaling was investigated in neural cell lines with fluorescent live cell imaging. The probe Fluo‐4 was used to measure Ca2+ in HT22 mouse hippocampal neurons and nonelectrically excitable U87 human glioblastoma cells exposed to 50 to 500 ms infrared pulses at 1470 nm. Fluorescence recordings of Fluo‐4 demonstrated that infrared stimulation induced an instantaneous intracellular Ca2+ transient with similar dose‐response characteristics in hippocampal neurons and glioblastoma cells (half‐maximal effective energy density EC50 of around 58 J.cm−2). For both type of cells, the source of the infrared‐induced Ca2+ transients was found to originate from intracellular stores and to be mediated by phospholipase C and IP3‐induced Ca2+ release from the endoplasmic reticulum. The activation of phosphoinositide signaling by IR light is a new mechanism of interaction relevant to infrared neural stimulation that will also be widely applicable to nonexcitable cell types. The prospect of infrared optostimulation of the PLC/IP3 cell signaling cascade has many potential applications including the development of optoceutical therapeutics.
- 9 August 2017
- Published by Wiley in Journal of Biophotonics
- Vol. 11 (2)
Infrared neural stimulation induces intracellular Ca2+ release mediated by phospholipase C
The influence of infrared laser pulses on intracellular Ca2+ signaling was investigated in neural cell lines with fluorescent live cell imaging. The probe Fluo‐4 was used to measure Ca2+ in HT22 mouse hippocampal neurons and nonelectrically excitable U87 human glioblastoma cells exposed to 50 to 500 ms infrared pulses at 1470 nm. Fluorescence recordings of Fluo‐4 demonstrated that infrared stimulation induced an instantaneous intracellular Ca2+ transient with similar dose‐response characteristics in hippocampal neurons and glioblastoma cells (half‐maximal effective energy density EC50 of around 58 J.cm−2). For both type of cells, the source of the infrared‐induced Ca2+ transients was found to originate from intracellular stores and to be mediated by phospholipase C and IP3‐induced Ca2+ release from the endoplasmic reticulum. The activation of phosphoinositide signaling by IR light is a new mechanism of interaction relevant to infrared neural stimulation that will also be widely applicable to nonexcitable cell types. The prospect of infrared optostimulation of the PLC/IP3 cell signaling cascade has many potential applications including the development of optoceutical therapeutics.