Cuffless Photoplethysmography Device for Continuous Monitoring of Blood Pressure
Preprint
Abstract
Introduction: Accurate and convenient monitoring of BP is challenging and relies on cuff-based devices or in the postoperative and intensive care settings, on invasive measurements. The aim of this study was to prospectively evaluate the accuracy of BP measurements obtained from a novel, commercially available cuffless, non-invasive photoplethysmography (PPG)-based chest patch monitor compared to the reference standard invasive arterial pressure (IAP) monitoring, in patients after cardiac surgery. Methods: This single center prospective study enrolled adults who underwent cardiac surgery. The PPG-based data were compared to IAP as part of standard of care. Bland-Altman plots and Pearson’s correlations were used to assess the accuracy between the two techniques. Results: Ninety-six patients consented for the study. Mean age was 63.2±12.2 years (range 24 to 84), and 32 (33%) were women. Average monitoring time was 25.6±17.2. In total, we evaluated 78659 readings for systolic BP (SBP), 78818 for diastolic BP (DBP), and 92544 for HR analysis. These yielded correlation coefficients of r=0.959, 0.973, 0.966, and 0.962 for SBP, DBP, mean arterial pressure (MAP), and heart rate (HR), respectively. The Bland-Altman analysis showed a bias±SD of 0.1±4.8 mmHg for SBP; 0.4±2.1 mmHg for DBP; 0.26±2.6 mmHg for MAP, and 0.15±3.6 beats per minutes for HR. 95% of SBP, and 99.9% of DBP measurements were within 10 mmHg of the reference measurement. Conclusion: Cuffless device offers a high level of accuracy of BP and HR, supporting the use of this novel noninvasive tool for continuous BP monitoring. Further studies are needed to validate those findings.Keywords
This publication has 19 references indexed in Scilit:
- Integrating skin color assessments into clinical practice and research: A review of current approachesJournal of the American Academy of Dermatology, 2024
- 2023 ESH Guidelines for the management of arterial hypertension The Task Force for the management of arterial hypertension of the European Society of Hypertension: Endorsed by the International Society of Hypertension (ISH) and the European Renal Association (ERA): ErratumJournal Of Hypertension, 2023
- European Society of Hypertension recommendations for the validation of cuffless blood pressure measuring devices: European Society of Hypertension Working Group on Blood Pressure Monitoring and Cardiovascular VariabilityJournal Of Hypertension, 2023
- COMPARISON STUDY FOR 24H AMBULATORY BLOOD PRESSURE MEASUREMENT (ABPM) WITH BIOBEAT PATCH ABPM® CUFFLESS WEARABLE DEVICE IN SUBJECTS WITH DIFFERENT BODY MASS INDEXJournal Of Hypertension, 2023
- Evaluation of the ability of a commercially available cuffless wearable device to track blood pressure changesJournal Of Hypertension, 2023
- Validating cuffless continuous blood pressure monitoring devicesCardiovascular Digital Health Journal, 2023
- Wearable cuffless blood pressure monitoring devices: a systematic review and meta-analysisEuropean Heart Journal - Digital Health, 2022
- Comparing blood pressure measurements between a photoplethysmography-based and a standard cuff-based manometry deviceScientific Reports, 2020
- 2017 ACC/AHA/AAPA/ABC/ACPM/AGS/APhA/ASH/ASPC/NMA/PCNA Guideline for the Prevention, Detection, Evaluation, and Management of High Blood Pressure in AdultsJACC, 2018
- Blood pressure lowering for prevention of cardiovascular disease and death: a systematic review and meta-analysisThe Lancet, 2016