Important reduction of the radiation dose for pulmonary vein isolation using a multimodal approach
Authors:
- 7 December 2016
- journal article
- research article
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 20 (2) , 279-287
Abstract
Aims The number of pulmonary vein isolation (PVI) ablation procedures is steadily increasing worldwide resulting in a substantial radiation exposure to patients and operators. The aim of our study was to reduce radiation exposure during these procedures to a critical amount without compromising patient safety. Methods and results First, we assessed radiation exposure for primary PVI procedures over time (2005-2015) at the University Heart Center Freiburg-Bad Krozingen. Second, we prospectively evaluated in 52 patients, the efficacy and safety of a novel radiation reduction program (particularly applying an enhanced fluoroscopy pulse dose-reduction and optimized 3D-mapping system use). In 2035 primary PVI procedures, radiation exposure, assessed as estimated effective dose (eED in mSv, dose area product * 0.002 * conversion factor for females), fluoroscopy-time, and procedure-time decreased significantly from 2005 to 2015 (e.g. eED decreased from 9.3 (interquartile range (IQR) 6.4-13.4) mSv to 0.9 (IQR 0.5-1.6) mSv, p for trend< 0.001). Importantly, application of the enhanced radiation reduction program further reduced eED to 0.4 mSv (IQR 0.3-0.6, P< 0.001 vs. control), a value not significantly different from slow-pathway ablation procedures (P = 0.41). Multiple linear regression analysis identified the radiation reduction program as the only independent variable associated with a decrease in radiation exposure. Conclusion Radiation exposure during PVI decreased over the last decade and can further be reduced significantly by the implementation of an enhanced radiation reduction program.Keywords
This publication has 15 references indexed in Scilit:
- Reducing Radiation Exposure in the Electrophysiology Laboratory: It is More Than Just Fluoroscopy Times!Pacing and Clinical Electrophysiology, 2014
- Contact-force guided radiofrequency vs. second-generation balloon cryotherapy for pulmonary vein isolation in patients with paroxysmal atrial fibrillation--a prospective evaluationEP Europace, 2014
- Practical ways to reduce radiation dose for patients and staff during device implantations and electrophysiological proceduresEP Europace, 2014
- Comparison of Pulmonary Vein Isolation Using Cryoballoon Versus Conventional Radiofrequency for Paroxysmal Atrial FibrillationThe American Journal of Cardiology, 2014
- The appropriate and justified use of medical radiation in cardiovascular imaging: a position document of the ESC Associations of Cardiovascular Imaging, Percutaneous Cardiovascular Interventions and ElectrophysiologyEuropean Heart Journal, 2014
- Catheter ablation of atrial fibrillation supported by novel nonfluoroscopic 4D navigation technologyHeart Rhythm, 2013
- Obesity Is a Major Determinant of Radiation Dose in Patients Undergoing Pulmonary Vein Isolation for Atrial FibrillationJACC, 2007
- Small or Large Isolation Areas Around the Pulmonary Veins for the Treatment of Atrial Fibrillation?Circulation, 2007
- Electrical isolation of pulmonary veins in patients with atrial fibrillation: reduction of fluoroscopy exposure and procedure duration by the use of a non-fluoroscopic navigation system (NavX®)EP Europace, 2006
- Radiation Exposure During Catheter Ablation of Atrial FibrillationCirculation, 2004