SmartPulse, a machine learning approach for calibration‐free dynamic RF shimming: Preliminary study in a clinical environment
- 30 June 2019
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 82 (6) , 2016-2031
Abstract
Purpose: A calibration‐free pulse design method is introduced to alleviate artifacts in clinical routine with parallel transmission at high field, dealing with significant inter‐subject variability, found for instance in the abdomen.Theory and Methods: From a dual‐transmit 3T scanner, a database of and off‐resonance abdominal maps from 50 subjects was first divided into 3 clusters based on mutual affinity between their respective tailored kT‐points pulses. For each cluster, a kT‐points pulse was computed, minimizing normalized root‐mean‐square flip angle deviations simultaneously for all subjects comprised in it. Using 30 additional subjects' field distributions, a machine learning classifier was trained on this 80‐labeled‐subject database to recognize the best pulse from the 3 ones available, relying only on patient features accessible from the preliminary localizer sequence present in all protocols. This so‐called SmartPulse process was experimentally tested on an additional 53‐subject set and compared with other pulse types: vendor's hard calibration‐free dual excitation, tailored static radiofrequency shimming, universal and tailored kT‐points pulses.Results: SmartPulse outperformed both calibration‐free approaches. Tailored static radiofrequency shimming yielded similar flip angle homogeneity for most patients but broke down for some while SmartPulse remained robust. Although flip angle homogeneity was systematically better with tailored kT‐points, the difference was barely noticeable on in vivo images.Conclusion: The proposed method paves the way toward an efficient trade‐off between tailored and universal pulse design approaches for large inter‐subject variability. With no need for on‐line field mapping or pulse design, it can fit seamlessly into a clinical protocol.Keywords
Funding Information
- CEA's Programme Transversal, Technologies pour la Santé
This publication has 36 references indexed in Scilit:
- Parallel-transmission-enabled magnetization-prepared rapid gradient-echo T1-weighted imaging of the human brain at 7TNeuroImage, 2012
- Magnetic resonance imaging: Review of imaging techniques and overview of liver imagingWorld Journal of Radiology, 2010
- Improvement in B1‐inhomogeneity artifacts in the abdomen at 3T MR imaging using a radiofrequency cushionJournal of Magnetic Resonance Imaging, 2008
- Magnitude least squares optimization for parallel radio frequency excitation design demonstrated at 7 Tesla with eight channelsMagnetic Resonance in Medicine, 2008
- Advanced three‐dimensional tailored RF pulse for signal recovery in T2*‐weighted functional magnetic resonance imagingMagnetic Resonance in Medicine, 2006
- Fast‐kzthree‐dimensional tailored radiofrequency pulse for reducedB1inhomogeneityMagnetic Resonance in Medicine, 2006
- Parallel excitation with an array of transmit coilsMagnetic Resonance in Medicine, 2004
- Transmit SENSEMagnetic Resonance in Medicine, 2002
- The effect of sex, age and race on estimating percentage body fat from body mass index: The Heritage Family StudyInternational Journal of Obesity, 2002
- Support-vector networksMachine Learning, 1995