Does an Adjustable-Loop Device Loosen following ACL Reconstruction with a Hamstring Graft? A Retrospective Study with a Follow-Up of Two Years
Open Access
- 24 June 2022
- journal article
- research article
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 11 (13) , 3648
Abstract
Arthroscopic anatomic anterior cruciate ligament reconstruction (ACLR) is the gold standard treatment for an ACL tear and requires the use of fixed or adjustable-loop devices to fix a femoral-side graft. Although the adjustable mechanism is designed to provide one-way tensioning, there is a concern that the adjustable loop will loosen and lengthen during cyclic loads, creating graft laxity. The present paper is a retrospective study of patients who underwent ACLR with the fixation of a hamstring graft with an adjustable loop on the femoral side from November 2016 to October 2018. The knee’s functional outcome was evaluated using an International Knee Documentation Committee (IKDC) score, Lysholm score, Lachman test, and pivot shift test. The patients were assessed preoperatively and finally postoperatively after two years of surgery. Thirty-two patients were analyzed. Significant improvement was obtained in the final clinical outcome of the patients. Twenty-seven patients (84.4%) were Lachman negative, and twenty-eight patients (87.5%) were pivot shift test negative, the mean Lysholm score was 96.91, and the IKDC score was 91.47 (p < 0.001). There was no infection, graft failure, or flexion restriction. Arthroscopic ACLR with an adjustable-loop suspensory device is a successful fixation method for femoral-side graft fixation and offers a similar functional outcome as with fixed-loop devices.Keywords
Funding Information
- King Saud University, Deanship of Scientific Research, Vice Deanship of Scientific Research Chairs; Rehabilitation Research Chair
This publication has 35 references indexed in Scilit:
- Clinical Results Comparing Transtibial Technique and Outside in Technique in Single Bundle Anterior Cruciate Ligament ReconstructionKnee Surgery & Related Research, 2013
- Femoral Cortical Suspension Devices for Soft Tissue Anterior Cruciate Ligament ReconstructionThe American Journal of Sports Medicine, 2012
- Measures of knee function: International Knee Documentation Committee (IKDC) Subjective Knee Evaluation Form, Knee Injury and Osteoarthritis Outcome Score (KOOS), Knee Injury and Osteoarthritis Outcome Score Physical Function Short Form (KOOS‐PS), Knee Outcome Survey Activities of Daily Living Scale (KOS‐ADL), Lysholm Knee Scoring Scale, Oxford Knee Score (OKS), Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), Activity Rating Scale (ARS), and Tegner Activity Score (TAS)Arthritis Care & Research, 2011
- All‐Inside Anterior Cruciate Ligament Graft‐Link Technique: Second‐Generation, No‐Incision Anterior Cruciate Ligament ReconstructionArthroscopy, 2011
- Three Femoral Fixation Devices for Anterior Cruciate Ligament Reconstruction: Comparison of Fixation on the Lateral Cortex Versus the Anterior CortexArthroscopy, 2010
- Anterior cruciate ligament reconstruction: Assessment of the hamstring autograft femoral fixation using the EndoButton CL®Orthopaedics & Traumatology: Surgery & Research, 2009
- Reliability of the KT1000 arthrometer and the Lachman test in patients with an ACL ruptureThe Knee, 2008
- Reliability and validity of the International Knee Documentation Committee (IKDC) Subjective Knee FormJoint Bone Spine, 2007
- Clinical evaluation of arthroscopically assisted anterior cruciate ligament reconstruction: Patellar tendon versus gracilis and semitendinosus autograftArthroscopy, 2005
- Clinical diagnosis and instrumented measurement of anterior knee laxity. A comparative study of the Lachman test, KT 1000 knee ligament arthrometer and the sonographic Lachman testDer Unfallchirurg, 1998