Outcomes of reverse shoulder arthroplasty using a mini 25-mm glenoid baseplate
- 1 August 2015
- journal article
- Published by Springer Nature in International Orthopaedics
- Vol. 40 (1) , 109-113
Abstract
As worldwide use of reverse shoulder arthroplasty (RSA) increases, a range of implant sizes may be required to match regional and ethnic variation in patients’ height and bone size. The purpose of this study was to report the outcomes of RSA using a mini 25-mm-diameter glenoid baseplate in smaller patients with rotator cuff arthropathy. Between 2009 and 2012, 28 patients underwent RSA for cuff-tear arthropathy using a 25-mm circular glenoid baseplate (Aequlais Reversed, Tornier, Bloomington, MN, USA). Twenty-four patients were able to return for comprehensive follow-up. The mean height of the entire cohort was 158 ± 10 cm (5 ft. 2 in.). The indication to use a smaller baseplate was a combination of preoperative templating using computed tomography (CT) and intraoperative measurements of glenoid width. At a mean of 36 ± 8 months’ follow-up, there were no revisions or glenoid-sided failures. The mean American Shoulder and Elbow Surgeons (ASES) score was 70 ± 10, the Simple Shoulder Test (SST) was 10 ± 2, the Constant was 60 ± 10 and the Disabilities of the Arm, Shoulder and Hand (DASH) was 18 ± 15. Mean active forward elevation was 140 ± 15°, active external rotation was 21 ± 15° and active internal rotation was to the sacroiliac joint. Mean shoulder strength in flexion was 5.2 ± 1.7 kg, in external rotation was 2.9 ± 1.4 kg and in internal rotation was 4.3 ± 1.2 kg. Radiographs demonstrated no evidence of glenoid loosening. There was, however, a 62 % rate of scapular notching. Short-term outcomes of mini 25-mm baseplate RSA in proportionally smaller patients are good and demonstrate implant safety and effectiveness. Scapular notching rates are worrisome, and additional follow-up is necessary to determine if notching is progressive and becomes symptomatic.Keywords
This publication has 16 references indexed in Scilit:
- Uncemented versus cemented humeral stem fixation in reverse shoulder arthroplastyInternational Orthopaedics, 2014
- Morphometric measurement of the patella on 3D model reconstructed from CT scan images for the southern Chinese populationChinese Medical Journal, 2014
- Comparison of Hemiarthroplasty and Reverse Arthroplasty for Treatment of Proximal Humeral FracturesJournal of Bone and Joint Surgery, 2013
- Early clinical results of reverse total shoulder arthroplasty in the Korean populationJournal of Shoulder and Elbow Surgery, 2013
- Stature estimation from scapular measurements by CT scan evaluation in an Italian populationLegal Medicine, 2013
- The use of an eccentric glenosphere compared with a concentric glenosphere in reverse total shoulder arthroplasty: two-year minimum follow-up resultsInternational Orthopaedics, 2013
- Complications with reverse total shoulder arthroplasty and recent evolutionsInternational Orthopaedics, 2013
- Bony Increased-offset Reversed Shoulder Arthroplasty: Minimizing Scapular Impingement While Maximizing Glenoid FixationClinical Orthopaedics and Related Research, 2011
- Grammont inverted total shoulder arthroplasty in the treatment of glenohumeral osteoarthritis with massive rupture of the cuffThe Journal of Bone and Joint Surgery. British volume, 2004
- Outcome of total hip arthroplasty in small-proportioned patientsThe Journal of Arthroplasty, 2000