Evaluation of the efficacy of modal analysis in predicting the pullout strength of fixation bone screws
Open Access
Abstract
Background: Pilot hole preparation has been shown to have an impact on the short and long‐term stability of the screw fixation constructs.Purpose: Investigation and comparison of two nondestructive modal analysis methods with conventional insertion torque (IT) and pullout tests in optimum pilot hole diameter detection.Methods: Twenty conical core titanium screws were embedded in high‐density polyethylene blocks with different pilot hole diameters. The maximum IT was recorded for each screw during implantation. Then, two modal analysis methods including accelerometer (classical modal analysis [CMA]) and acoustic modal analysis (AMA) were carried out to measure the natural frequency (NF) of the bone‐screw structure. Finally, stiffness (S), pullout force (Fult), displacement at Fult (dult) and energy dissipation (ED) were obtained from the destructive pullout test.Results: The IT increased, as the pilot hole diameter decreased. The maximum value of IT was observed in the smallest pilot hole diameter. The same trend was found for the Fult and the first NF derived from both modal methods except for 5.5 mm pilot hole diameter. The natural NFs derived from CMA and AMA showed high correlations in different groups (R2 = 0.94) and did not deviate from y = x hypothesis in linear regression analysis. The Fult, dult, and ED were measured 4800 ± 172 N, 3.10 ± 0.08 mm and 14.23 ± 1.10 N.mm, respectively.Discussion: No significant change was observed in “S” between the groups. The highest Fult and first NF were obtained for the 5.5 mm pilot hole diameter. Both CMA and AMA were found to be reliable methods and can promote the undesirable contradiction between Fult and IT.Keywords
This publication has 39 references indexed in Scilit:
- Assessment of pedicle screw pullout strength based on various screw designs and bone densities—an ex vivo biomechanical studyThe Spine Journal, 2012
- Pullout strength of pedicle screws with cement augmentation in severe osteoporosis: A comparative study between cannulated screws with cement injection and solid screws with cement pre-fillingBMC Musculoskeletal Disorders, 2011
- Insertion torque is not a good predictor of pedicle screw loosening after spinal instrumentation: a prospective study in 8 patientsPatient Safety in Surgery, 2010
- The role of primary stability for successful immediate loading of dental implants. A literature reviewJournal of Dentistry, 2010
- A Comparison of Screw Insertion Torque and Pullout StrengthJournal of Orthopaedic Trauma, 2010
- The Effect of Repetitive Pilot-Hole Use on the Insertion Torque and Pullout Strength of Vertebral System ScrewsSpine, 2009
- Effect of Micrometer-Scale Roughness of the Surface of Ti6Al4V Pedicle Screws in Vitro and in VivoJournal of Bone and Joint Surgery, 2008
- Estudo da influência do diâmetro do orifício piloto na resistência ao arrancamento do parafuso pedicularActa Ortopedica Brasileira, 2008
- Long stemmed total knee arthroplasty with interlocking screws: A computational bone adaptation studyJournal of Orthopaedic Research, 2004
- Mechanical Vibration Analysis and ComputationThe Journal of the Acoustical Society of America, 1990