AHAta Hashemi

Ata Hashemi

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Ata Hashemi has a total of 45 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Experimental and coupled quasi-linear viscoelastic biphasic modeling of regional and strain-rate dependent tensile behavior in the temporomandibular joint disc

    by Saeed Salehi Pourbavarasad, Ata Hashemi

    The temporomandibular joint (TMJ) is a load-bearing fibrocartilaginous articulation that sustains combined tension, compression, and shear. Although the TMJ disc exhibits strong regional and directional heterogeneity, its tensile properties and strain-rate dependence remain insufficiently characterized. Ovine TMJ discs were tested in the anterior, central, and posterior regions along the anteroposterior (AP) and mediolateral (ML) directions at strain rates of 0.1, 0.5, and 1%/s. Stress–strain curves were quantified, and the time-dependent response was modeled using a coupled quasi-linear viscoelastic (QLV) and biphasic framework. All specimens exhibited a nonlinear toe region followed by a linear tensile response. The AP direction showed substantially higher stiffness (up to 70 MPa), with the central region demonstrating the greatest modulus and ultimate tensile stress. Strain rate significantly influenced stiffness, with rate sensitivity more pronounced in the AP direction than in the ML direction (p < 0.05). The coupled QLV-biphasic model accurately reproduced the nonlinear elastic response (R² = 0.90–0.95). Fluid-phase parameters were adopted from the literature, while solid-phase parameters were identified by fitting to the experimental tensile data. These findings provide region- and direction-specific viscoelastic parameters to improve finite element modeling and support the design of mechanically appropriate disc replacements.

  • Protective Pads Significantly Lower the Mandibular Symphysis Fractures under Frontal Impact: Experimental and FE Study

    by Hosna Olfati, Ata Hashemi

    Mandible fractures are a prevalent type of facial injury mostly caused by impact forces. The potential use of protective materials, such as foam, as energy absorbers reduces the effects of harmful dynamic loads on the mandible. This study explores the effectiveness of expanded polystyrene (EPS) foam of two different thicknesses as shock absorbers in mitigating the risk of mandible fractures during frontal impacts to the mandibular symphysis. A three-dimensional finite element model (FEM) of the human mandible was developed to simulate impact scenarios both with and without the shock absorber. Symphysis impact tests identified two critical zones, the condylar process and the symphysis area. By analyzing stress distributions and potential fracture sites, the study aims to determine whether EPS foam can alter the mandible's response to impact and how varying foam thicknesses influence this effect. The results revealed that the symphysis region and condylar neck experienced the highest first principal stresses during the impact, as determined by the FEM and observed fracture sites. The drop height required to cause mandibular fractures was experimentally measured to increase by 100% and 128% with the inclusion of 19 mm and 31 mm EPS foams, respectively, mitigating trauma to the mandible. Similarly, kinetic energy measurements indicated an increase from 7.1 J for samples without protective foam to 14.2 J and 16.3 J for samples with 19 mm and 31 mm EPS foam pads, respectively. The findings, validated by both FEM and experimental drop tests, provide valuable insights for the design of protective equipment aimed at reducing the severity and frequency of facial trauma and injuries in high-risk activities.

  • Viscoelastic Properties in Fixational Stability of Pedicle Screws in Uhwmpe Block: a Finite Element Study

    by Ahmad Babazadeh Gh, Mohammadjavad Einafshar, Ata Hashemi

    Pedicle screws are critical components in spinal fixation systems, and the stiffness of the screw-bone interaction plays a crucial role in implant success. There are various ways to investigate screw-bone bonding strength, one of which is vibration-based diagnosis of screw-bone structure. While finite element modeling can reduce the time and give the ability to model different geometries and other conditions, properly modeling the vibration behavior of the screw inside the bone comes with difficulties. This study investigates the influence of insertion-induced prestress and the viscoelastic properties of ultra-high molecular weight polyethylene (UHMWPE) boneanalog material on the natural frequency of a pedicle screwblock assembly using finite element analysis (FEA). Three models were developed: Model I (linear elastic without prestress), Model II (linear elastic with prestress), and Model III (viscoelastic without prestress). A 3D geometry of the screw and UHMWPE block was constructed, and frequency analysis was performed at three insertion depths ($10 \text{mm}, 20 \text{mm}$, and 30 $\text{mm)}$. Simulation results were compared with previously published experimental data. Model I underestimated the natural frequency at all depths around $14-30 \%$, while Model II, accounting for screw insertion-induced radial prestress, improved prediction accuracy, reducing errors down to under 18 %. Model III, which captured UHMWPE's viscoelastic behavior using a Prony series, showed the closest agreement with experimental data, with errors under 7 %. The results highlight the importance of modeling both viscoelasticity and insertion-related prestress to accurately predict dynamic behavior. These findings are useful for improving finite element modeling of modal analysis methods to investigate screw stability in spinal implants.

  • Role of Protective Pads in Mandibular Biomechanics During Frontal Impact

    by Hosna Olfati, Ata Hashemi

    Mandibular fractures are common maxillofacial injuries, frequently resulting from sports, traffic accidents, and violence. Despite advancement in protective strategies, the role of external protective pads in mitigating impact forces to the mandible remains underexplored. This study develops a computational model of the human jaw to evaluate the biomechanical effectiveness of expanded polystyrene pads in reducing stress concentration during frontal impact. A 3D finite element model of the lower jaw was constructed using high-resolution computed tomography data and assigned density-based heterogenous material properties to it. The mandible was subjected to a frontal impact under three configurations: no protective pad, with a 19 mm EPS pad and with a 31 mm EPS pad. Results demonstrated that both EPS pads reduced impact severity. Compared to the unprotected model, the peak impact force decreased by approximately 67 % and 71 %, respectively, with the 19 mm and 31 mm foams. Maximum first principal stress was reduced from $\mathbf{4 0 4 ~ M P a}$ for unprotected mandible to 170 MPa, and 158 MPa for mandibles with EPS foam thicknesses of 19 and 31 mm, respectively. This research indicated that the application of EPS foam led to an extended impact duration with a reduced peak force, thereby decreasing stress on the mandible. Incorporating a shock-absorbing EPS layer significantly mitigates the risk of mechanical injury during frontal impacts.

  • Larger lateral hinges increase the probability of Takeuchi type II and III fractures in high tibial osteotomy

    by Zahra Saghaei, Saeed Salehipour, Ata Hashemi

    Purpose Lateral hinge fractures are the main complications in the high tibial osteotomy to treat varus deformities. The aim of present study is to answer the question whether the lateral hinge length (H) has an effect on the type of fracture and required force during the opening in high tibia osteotomy. It was hypothesized in this comparative research that extending the hinge length increased opening force and probability of a type II and type III fractures. Methods A monoplanar medial open wedge osteotomy with different intact hinge lengths varying from 9 to 32 mm was performed in 20 ostrich bones. A biomechanical experiment using unidirectional tensile testing apparatus was performed to open the wedge, and the required force was increased until a 10 mm opening was reached; then, the presence of fracture in the lateral cortex and its direction were evaluated. Lateral hinge fracture type based on direction was classified as suggested by Takeuchi et al. Results Fracture that grows along the osteotomy line (type I) was observed in 4 samples with the mean hinge length (H) of 11 ± 1.54 mm. For seven bones with Takeuchi fracture type II, with downward crack propagation, the mean H was 16 ± 3.36 mm. For the mean H of 25 ± 6.53 mm, the crack propagated upward to the cutting path, displaying a Takeuchi type III fracture in seven samples. The statistical analysis showed that the fracture type significantly depends on the hinge length (P value < 0.05). Also, the mean opening force significantly increased with hinge lengthening (P value < 0.05). The peak forces at crack initiation were 41.8 ± 21.9, 115.2 ± 41.5, and 167 ± 135.3 N, respectively, for the fracture types I, II, and III samples. Conclusion The lateral cortical hinge length was significantly associated with hinge fracture type. The experimental tests indicated that the hinge lengthening increases the risk of type II and III fractures, as classified by Takeuchi.


  • Effect of temperature on dynamic compressive behavior of periodontal ligament

    by Mohammad Najafidoust, Ata Hashemi, Iman Z. Oskui

    Periodontal ligament (PDL) attaches tooth root to the surrounding bone. Its existence between tooth and jaw bone is of utmost importance due to its significant role in absorbing and distributing physiological and para-physiological loading. According to the previous studies, various mechanical tests have been performed to characterize the mechanical properties of the PDL; however, all of them have been done at room temperature. To the best of our knowledge, this is the first study in which the testing was performed at body temperature. The present research was planned to measure the dependency of PDL's viscoelastic behavior on temperature and frequency. Three different temperatures, including body and room temperature, were opted to perform the dynamic compressive tests of the bovine PDL. In addition, a Generalized Maxwell model (GMM) was presented based on empirical outcomes. At 37 °C, amounts of loss factor were found to be greater than those in 25 °C, which demonstrates that the viscous phase of the PDL in higher temperatures plays a critical role. Likewise, by raising the temperature from 25 °C to 37 °C, the model parameters show an enlargement in the viscous part and lessening in the elastic part. It was concluded that the PDL's viscosity in body temperature is much higher than that in room temperature. This model would be functional for a more accurate computational analysis of the PDL at the body temperature (37 °C) in various loading conditions such as orthodontic simulations, mastication, and impact.


  • Homogeneous material models can overestimate stresses in high tibial osteotomy: A finite element analysis

    by Zahra Saghaei, Ata Hashemi

    Although widely used numerical models can assess the stability of lateral hinges in high tibial osteotomy (HTO) and may provide acceptable results in comparative studies, accurate stress prediction may not be possible due to simplified homogeneous models of the bone. The present study aimed to investigate the effect of a heterogeneous versus four homogeneous models on the results of stress and force. Each of the four homogenized FE models utilized the same elastic modulus of 16,700 MPa for the cortical while employing a single elastic modulus varying from 155 to 5000 MPa for the cancellous. In heterogeneous model, the modulus of each element was assigned using the bone density. It was found that stresses at the hinge in homogeneous models were higher than those in the heterogeneous model. The maximum principal stress (MPS) was 437 MPa for the heterogeneous model while that was 2179, 2351, 2581, and 2637 MPa for the homogeneous models with the elastic moduli of 155, 500, 2130, and 5000 MPa, respectively. Also, the opening force was 150 N for the heterogeneous model significantly lower than 649–1534 N range predicted for the homogeneous models. The use of a homogeneous model in the FE analysis of HTO overestimated the stresses and force. Thus, in addition to casting doubt on the use of a single modulus in the numerical analysis of HTO, Future HTO studies can use our results as a benchmark for comparison purposes and highlight the use of patient-specific bone density – elastic modulus relation in simulation.


  • Open Access

    Evaluation of the efficacy of modal analysis in predicting the pullout strength of fixation bone screws

    by Mohammadjavad Einafshar, Ata Hashemi, Ali Kiapour

    Background: Pilot hole preparation has been shown to have an impact on the short and long‐term stability of the screw fixation constructs.Purpose: Investigation and comparison of two nondestructive modal analysis methods with conventional insertion torque (IT) and pullout tests in optimum pilot hole diameter detection.Methods: Twenty conical core titanium screws were embedded in high‐density polyethylene blocks with different pilot hole diameters. The maximum IT was recorded for each screw during implantation. Then, two modal analysis methods including accelerometer (classical modal analysis [CMA]) and acoustic modal analysis (AMA) were carried out to measure the natural frequency (NF) of the bone‐screw structure. Finally, stiffness (S), pullout force (Fult), displacement at Fult (dult) and energy dissipation (ED) were obtained from the destructive pullout test.Results: The IT increased, as the pilot hole diameter decreased. The maximum value of IT was observed in the smallest pilot hole diameter. The same trend was found for the Fult and the first NF derived from both modal methods except for 5.5 mm pilot hole diameter. The natural NFs derived from CMA and AMA showed high correlations in different groups (R2 = 0.94) and did not deviate from y = x hypothesis in linear regression analysis. The Fult, dult, and ED were measured 4800 ± 172 N, 3.10 ± 0.08 mm and 14.23 ± 1.10 N.mm, respectively.Discussion: No significant change was observed in “S” between the groups. The highest Fult and first NF were obtained for the 5.5 mm pilot hole diameter. Both CMA and AMA were found to be reliable methods and can promote the undesirable contradiction between Fult and IT.


  • Replacement of Destructive Pull-out Test with Modal Analysis in Primary Fixation Stability Assessment of Spinal Pedicle Screw

    by Mohammad Javad Ein-Afshar, Ata Hashemi, Harry Van Lenthe

    Background context: Pedicle screw fixation devices are the predominant stabilization systems for a wide variety of spinal defects. Accordingly, both pedicle screw design and bone quality are known as the main parameters affecting the fixation strength as measured by the pull-out force and insertion torque. Objective: A non-destructive method was proposed to evaluate the mechanical stability of screw. Natural frequency (ωn) extracted from the modal analysis was then correlated with peak pull-out force (PPF) and peak insertion torque (PIT). Methods: Cylindrical pedicle screws were inserted into two different polyurethane (PU) foams with densities of 0.16 and 0.32 g/cm3. The PIT and PPT were measured. Modal analysis was carried out through recording time response of an accelerometer attached to the head of the screw impacted by a shock hammer. The effect of the insertion depth and foam density on the insertion torque, natural frequency and pull-out force were quantified. Results: The maximum values of ωn, PIT and PPT obtained 2186 Hz, 123.75 N.cm and 981.50 N, respectively when the screw was inserted into the high-density foam at depth of 30 mm. The minimum values were measured 332 Hz, 16 N.cm and 127 N, respectively, within the low-density PU at the depth of 10 mm. The higher value of ωn was originated from higher bone screw stability and thus more fixation strength. According to the regression analysis outcomes, the natural frequency (ωn) was linearly dependent on the peak insertion torque (PIT) (ωn=14PIT) and also on the peak pull-out force (PPF) (ωn=1.7PPF). Conclusions: The modal analysis was found to be a reliable, repeatable and non-destructive method, which could be considered as a prospective alternative to destructive pull-out test, which is limited to in-vitro application only. The modal analysis could be applied to assess the stability of implantable screws like orthopedic and spinal screws.