Impact of Stem Collar-Calcar Gap Distance on Postoperative Bone Remodeling in Fully Hydroxyapatite-coated Stem
Authors:
Preprint
- 7 October 2024
- preprint
- Published by Springer Nature in Research Square
Abstract
The collar of a cementless stem in total hip arthroplasty (THA) improves fixation and stability by connecting with the femoral calcar. Proper attachment is essential for reducing micromotion and preventing periprosthetic fractures of the femur. However, gaps between the femoral calcar and stem collar can occur during surgery, and it is unclear what degree of gap can be tolerated. This study evaluated 156 patients who received primary THA with the CORAIL stem. Medial and lateral gap distance were measured by frontal X-ray of the hip joint at 1 week and 1, 3, 6, 12, 24, and 36 months after THA. Clinical outcomes were assessed using Japanese Orthopaedic Association hip scores, and radiographic assessments included femoral morphology and stem alignment. Gaps were initially observed in 55 patients, with 42 showing complete gap disappearance within 36 months. On logistic regression analysis, lateral gap distance was shown to significantly influence gap disappearance, with an optimal cut-off of 5.5 mm by receiver operating characteristic curve analysis. A smaller lateral gap was correlated with quicker closure. When the gap between the collar and femoral calcar is within 5.5 mm, gap disappearance can be expected due to postoperative bone remodeling.Keywords
All Related Versions
- Version 1, 2024-10-07, Research Square
- Published version: Scientific Reports, 15 (1), 1.
This publication has 19 references indexed in Scilit:
- Influence of broach surface design of a fully hydroxyapatite coated, double tapered stem on periprosthetic bone mineral density after total hip arthroplasty: a study based on the morphology of the proximal femurArchives of orthopaedic and trauma surgery, 2024
- Primary Stability of Collared and Collarless Cementless Femoral Stems – A Finite Element Analysis StudyArthroplasty Today, 2023
- Hydroxyapatite-coated compaction short stem represents a characteristic pattern of peri-prosthetic bone remodelling after total hip arthroplastyArchives of orthopaedic and trauma surgery, 2021
- Comparative outcomes between collared versus collarless and short versus long stem of direct anterior approach total hip arthroplasty: a systematic review and indirect meta-analysisEuropean Journal of Orthopaedic Surgery & Traumatology, 2019
- Clinical and Radiographic Outcomes at 25-30 Years of a Hip Stem Fully Coated With HydroxylapatiteThe Journal of Arthroplasty, 2018
- Effect of bone type on clinical and radiographic outcomes of a proximally-coated cementless stem in primary total hip arthroplastiesJournal of Orthopaedic Research, 2014
- Does a Collar Improve the Immediate Stability of Uncemented Femoral Hip Stems in Total Hip Arthroplasty? A Bilateral Comparative Cadaver StudyThe Journal of Arthroplasty, 2011
- Twenty-year results of the cementless Corail stemInternational Orthopaedics, 2010
- Reliability and validity of the Japanese Orthopaedic Association hip scoreJournal of Orthopaedic Science, 2010
- Structural and cellular assessment of bone quality of proximal femurBone, 1993