Impact of stem collar to femoral calcar gap distance on postoperative bone remodeling in a fully hydroxyapatite-coated stem
Open Access
- 24 May 2025
- journal article
- research article
- Published by Springer Nature in Scientific Reports
- Vol. 15 (1) , 1-8
Abstract
The collar of a cementless stem in total hip arthroplasty (THA) improves fixation and stability by connecting with the femoral calcar. Proper attachment is essential for reducing micromotion and preventing periprosthetic fractures of the femur. However, gaps between the femoral calcar and stem collar can occur during surgery, and it is unclear what degree of gap can be tolerated. This study evaluated 156 patients who received primary THA with the CORAIL stem. Medial and lateral gap distance were measured by frontal X-ray of the hip joint at 1 week and 1, 3, 6, 12, 24, and 36 months after THA. Clinical outcomes were assessed using Japanese Orthopaedic Association hip scores, and radiographic assessments included femoral morphology and stem subsidence. Gaps were initially observed in 55 patients, with 42 showing complete gap disappearance within 36 months. On logistic regression analysis, lateral gap distance was shown to significantly influence gap disappearance, with an optimal cut-off of 5.5 mm by receiver operating characteristic curve analysis. A smaller lateral gap was correlated with quicker closure. Our findings suggest that a lateral gap ≤ 5.5 mm allows postoperative bone remodeling to close the gap, contributing to long-term implant stability in THA using the CORAIL stem.Keywords
All Related Versions
This publication has 20 references indexed in Scilit:
- Comparative outcomes between collared versus collarless and short versus long stem of direct anterior approach total hip arthroplasty: a systematic review and indirect meta-analysisEuropean Journal of Orthopaedic Surgery & Traumatology, 2019
- Femoral Stem Survivorship in Dorr Type A Femurs After Total Hip Arthroplasty Using a Cementless Tapered Wedge Stem: A Matched Comparative Study With Type B FemursThe Journal of Arthroplasty, 2019
- Femoral stem subsidence in cementless total hip arthroplasty: a retrospective single-centre studyInternational Orthopaedics, 2018
- Impact of Femoral Stem Design on Failure After Anterior Approach Total Hip ArthroplastyThe Journal of Arthroplasty, 2018
- Clinical and Radiographic Outcomes at 25-30 Years of a Hip Stem Fully Coated With HydroxylapatiteThe Journal of Arthroplasty, 2018
- Effect of bone type on clinical and radiographic outcomes of a proximally-coated cementless stem in primary total hip arthroplastiesJournal of Orthopaedic Research, 2014
- Does a Collar Improve the Immediate Stability of Uncemented Femoral Hip Stems in Total Hip Arthroplasty? A Bilateral Comparative Cadaver StudyThe Journal of Arthroplasty, 2011
- Twenty-year results of the cementless Corail stemInternational Orthopaedics, 2010
- Reliability and validity of the Japanese Orthopaedic Association hip scoreJournal of Orthopaedic Science, 2010
- Structural and cellular assessment of bone quality of proximal femurBone, 1993