Blood Pressure Measurement Device Accuracy Evaluation: Statistical Considerations with an Implementation in R
Open Access
- 25 March 2024
- journal article
- research article
- Published by MDPI AG in Technologies
- Vol. 12 (4) , 44
Abstract
Inaccuracies from devices for non-invasive blood pressure measurements have been well reported with clinical consequences. International standards, such as ISO 81060-2 and the seminal AAMI/ANSI SP10, define protocols and acceptance criteria for these devices. Prior to applying these standards, a sample size of N >= 85 is mandatory, that is, the number of distinct subcjects used to calculate device inaccuracies. Often, it is not possible to gather such a large sample. Many studies apply these standards with a smaller sample. The objective of the paper is to introduce a methodology that broadens the method first developed by the AAMI Sphygmomanometer Committee for accepting a blood pressure measurement device. We study changes in the acceptance region for various sample sizes using the sampling distribution for proportions and introduce a methodology for estimating the exact probability of the acceptance of a device. This enables the comparison of the accuracies of existing device development techniques even if they were studied with a smaller sample size. The study is useful in assisting BP measurement device manufacturers. To assist clinicians, we present a newly developed “bpAcc” package in R to evaluate acceptance statistics for various sample sizes.Keywords
Funding Information
- Ministry of Business, Innovation and Employment (AUTX1904)
This publication has 22 references indexed in Scilit:
- A Novel Model for Continuous Cuff-less Blood Pressure Estimation2018
- Pulse Transit Time Based Continuous Cuffless Blood Pressure Estimation: A New Extension and A Comprehensive EvaluationScientific Reports, 2017
- Sources of inaccuracy in the measurement of adult patients’ resting blood pressure in clinical settingsJournal Of Hypertension, 2017
- Validation of the iHealth BP7 wrist blood pressure monitor, for self-measurement, according to the European Society of Hypertension International Protocol revision 2010Blood Pressure Monitoring, 2014
- Feasibility of cuff-free measurement of systolic and diastolic arterial blood pressureJournal of Electrocardiology, 2011
- Smart Vest: Wearable multi-parameter remote physiological monitoring systemMedical Engineering & Physics, 2007
- Measuring Blood Pressure AccuratelyJAMA, 2003
- Working Group on Blood Pressure Monitoring of the European Society of Hypertension International Protocol for validation of blood pressure measuring devices in adultsBlood Pressure Monitoring, 2002
- The Accuracy and Performance of the A&D TM 2421, a New Ambulatory Blood Pressure Monitoring Device Based on the Cuff-Oscillometric Method and the Korotkoff Sound TechniqueAmerican Journal of Hypertension, 1992
- The British Hypertension Society protocol for the evaluation of automated and semi-automated blood pressure measuring devices with special reference to ambulatory systemsJournal Of Hypertension, 1990