Preoperative Low Lumbar Hounsfield Units and Global Alignment Predict Postoperative Mechanical Complications After Adult Spinal Deformity Surgery: A Multicenter Retrospective Study
Authors:
- Ippei YamauchiIYIppei Yamauchi
- Hiroaki NakashimaHNHiroaki Nakashima
- Sadayuki ItoSISadayuki Ito
- Naoki SegiNSNaoki Segi
- Jun OuchidaJOJun Ouchida
- Yoshinori MoritaYMYoshinori Morita
- Yukihito OdeYOYukihito Ode
- Yasuhiro NagataniYNYasuhiro Nagatani
- Yuya OkadaYOYuya Okada
- Yosuke TakeichiYTYosuke Takeichi
- Yujiro KagamiYKYujiro Kagami
- Hiroto TachiHTHiroto Tachi
Open Access
- 16 June 2025
- journal article
- research article
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 14 (12) , 4267
Abstract
Objectives: This study investigated the potential of Hounsfield unit (HU) values obtained from computed tomography (CT) scans as predictors of mechanical complications (MCs) in patients undergoing long-segment spinal fusion involving the pelvis. Additionally, it identified a threshold HU value associated with an increased risk of MCs. Methods: We conducted a retrospective, multicenter review of patients who underwent long-segment spinal fusion involving the pelvis, with a minimum follow-up period of two years. Patients were categorized based on the presence or absence of postoperative MCs. Both preoperative and postoperative radiographic parameters were analyzed, and HU values were quantified from CT images. Logistic regression modeling was used to identify independent risk factors for MCs. Results: Among 129 patients, 33 (25.6%) developed MCs, including proximal and distal junctional failures, rod fractures, and cases necessitating re-operation. The HU values were significantly lower in the MC group, whereas conventional bone mineral density (BMD) measurements showed no significant difference. Global alignment parameters, such as the sagittal vertical axis (SVA) and global tilt (GT), were consistently higher in patients with MCs. Receiver operating characteristic analysis identified 131 HU as the optimal cut-off, yielding a sensitivity of 56.4% and a specificity of 69.7%. Multivariate analysis confirmed that lower HU values were independently associated with the occurrence of MCs. Conclusions: Lower HU values and larger radiological global alignment parameters are significant predictors of MCs in patients undergoing surgery for adult spinal deformity. These findings underscore the importance of CT-based quantitative assessments in preoperative planning.Keywords
This publication has 28 references indexed in Scilit:
- Importance of computed tomography Hounsfield units in predicting S1 screw loosening after lumbosacral fusionJournal of Clinical Neuroscience, 2023
- Relationship Between Hounsfield Units of Upper Instrumented Vertebrae, Proximal Junctional Failure, and Global Alignment and Proportion Score in Female Patients with Adult Spinal DeformityWorld Neurosurgery, 2022
- Modified global alignment and proportion scoring with body mass index and bone mineral density (GAPB) for improving predictions of mechanical complications after adult spinal deformity surgeryThe Spine Journal, 2020
- Hounsfield units value is a better predictor of pedicle screw loosening than the T-score of DXA in patients with lumbar degenerative diseasesEuropean Spine Journal, 2020
- Complications in adult spine deformity surgery: a systematic review of the recent literature with reporting of aggregated incidencesEuropean Spine Journal, 2018
- A Japanese nationwide multicenter survey on perioperative complications of corrective fusion for elderly patients with adult spinal deformityJournal of Orthopaedic Science, 2017
- Diagnostic efficacy of Hounsfield units in spine CT for the assessment of real bone mineral density of degenerative spine: correlation study between T-scores determined by DEXA scan and Hounsfield units from CTActa Neurochirurgica, 2016
- The cohort study for the determination of reference values for spinopelvic parameters (T1 pelvic angle and global tilt) in elderly volunteersEuropean Spine Journal, 2016
- Studies in the Modified Scoliosis Research Society Outcomes Instrument in Adults: Validation, Reliability, and Discriminatory CapacitySpine, 2003
- Impact of soft tissue on in vivo accuracy of bone mineral measurements in the spine, hip, and forearm: A human cadaver studyJournal of Bone and Mineral Research, 1995