Abstract
This paper investigates the effect of beam-column connection with semi-rigid rotational stiffness values on the behavior of different frame cases such as: support type and number of stories using ANSYS software. A previously studied model was selected for verification purposes. The support types that were chosen for this study are fixed-fixed and pinned-pinned connections. In terms of the number of stories, one-bay three-story and one-bay five-story frames were selected. The results of the numerical simulation showed that when the stiffness of beam-column connection is changed to semi-rigid connection of rotational stiffness value (25EI/L, 15EI/L and 10EI/L) can increases the maximum vertical displacement, horizontal displacement and maximum rotation by a percentages of (16.29, 35.42 and 17.43) % respectively for fixed-fixed support and percentages of (28.1, 26.8 and 15.44) % respectively for pinned-pinned support for semi-rigid connection when compared with rigid case. Changing the rotational stiffness of the beam-column connection to semi-rigid stiffness effect the load-displacement curve of the frame and make it less stiff. Moreover, the results showed that changing the number of stories from three to five stories with semi-rigid connections can increase the horizontal displacement by a percentage of 87 % for rotational stiffness of 10EI/L while for rigid case the percentage of increasing is 81%. This can indicate the importance of semi-rigid connection on the behavior of the frame in the analysis and design of steel structures.

This publication has 10 references indexed in Scilit: