A Novel Fetal Movement Simulator for the Performance Evaluation of Vibration Sensors for Wearable Fetal Movement Monitors
Authors:
- Abhishek Kumar GhoshAGAbhishek Kumar Ghosh
- Sonny F. BurnistonSBSonny F. Burniston
- Daniel KrentzelDKDaniel Krentzel
- Abhishek RoyARAbhishek Roy
- Adil Shoaib SheikhASAdil Shoaib Sheikh
- Talha SiddiqTSTalha Siddiq
- Paula Mai Phuong TrinhPTPaula Mai Phuong Trinh
- Marta Mambrilla VelazquezMVMarta Mambrilla Velazquez
- Hei-Ting VielleHVHei-Ting Vielle
- Niamh C. NowlanNNNiamh C. Nowlan
- Ravi VaidyanathanRVRavi Vaidyanathan
Open Access
Abstract
Fetal movements (FM) are an important factor in the assessment of fetal health. However, there is currently no reliable way to monitor FM outside clinical environs. While extensive research has been carried out using accelerometer-based systems to monitor FM, the desired accuracy of detection is yet to be achieved. A major challenge has been the difficulty of testing and calibrating sensors at the pre-clinical stage. Little is known about fetal movement features, and clinical trials involving pregnant women can be expensive and ethically stringent. To address these issues, we introduce a novel FM simulator, which can be used to test responses of sensor arrays in a laboratory environment. The design uses a silicon-based membrane with material properties similar to that of a gravid abdomen to mimic the vibrations due to fetal kicks. The simulator incorporates mechanisms to pre-stretch the membrane and to produce kicks similar to that of a fetus. As a case study, we present results from a comparative study of an acoustic sensor, an accelerometer, and a piezoelectric diaphragm as candidate vibration sensors for a wearable FM monitor. We find that the acoustic sensor and the piezoelectric diaphragm are better equipped than the accelerometer to determine durations, intensities, and locations of kicks, as they have a significantly greater response to changes in these conditions than the accelerometer. Additionally, we demonstrate that the acoustic sensor and the piezoelectric diaphragm can detect weaker fetal movements (threshold wall displacements are less than 0.5 mm) compared to the accelerometer (threshold wall displacement is 1.5 mm) with a trade-off of higher power signal artefacts. Finally, we find that the piezoelectric diaphragm produces better signal-to-noise ratios compared to the other two sensors in most of the cases, making it a promising new candidate sensor for wearable FM monitors. We believe that the FM simulator represents a key development towards enabling the eventual translation of wearable FM monitoring garments.Keywords
Funding Information
- Commonwealth Scholarship Commission (BDCS-2018-46)
- UK-India Education and Research Initiative (UKIERI) (DST-UKIERI-2016-17-0103)
This publication has 39 references indexed in Scilit:
- Design and evaluation of a novel microphone-based mechanomyography sensor with cylindrical and conical acoustic chambersMedical Engineering & Physics, 2012
- Predictors of Poor Perinatal Outcome following Maternal Perception of Reduced Fetal Movements – A Prospective Cohort StudyPLOS ONE, 2012
- Optimization and Initial Experience of a Multisection Balanced Steady-State Free Precession Cine Sequence for the Assessment of Fetal Behavior in UteroAmerican Journal of Neuroradiology, 2010
- Human Uterine Wall Tension Trajectories and the Onset of ParturitionPLOS ONE, 2010
- Maternal perception of foetal movement compared with movement detected by real‐time ultrasound: An exploratory studyAustralian and New Zealand Journal of Obstetrics and Gynaecology, 2010
- Computational pregnant occupant model, ‘Expecting’, for crash simulationsProceedings of the Institution of Mechanical Engineers, Part D: Journal of Automobile Engineering, 2009
- Decreased fetal movements: background, assessment, and clinical managementActa Obstetricia et Gynecologica Scandinavica, 2004
- The calibration of CT Hounsfield units for radiotherapy treatment planningPhysics in Medicine & Biology, 1996
- Maternal perception of fetal motor activity.BMJ, 1979
- Passive mechanical properties of uterine muscle (myometrium) tested in vitroJournal of Biomechanics, 1978