AGAbhishek Kumar Ghosh

Abhishek Kumar Ghosh

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Abhishek Kumar Ghosh has a total of 25 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Variability in Fetal Movement Patterns Captured by Different Wearable Sensors

    by Abhishek K. Ghosh, Mikdam-Al-Maad Ronoue, Ravi Vaidyanathan, Niamh C. Nowlan

    Fetal movement (FM) patterns serve as crucial biomarkers of fetal health. However, the reliance on intermittent, in-clinic ultrasound assessments has restricted our ability to track the longitudinal progression of FM patterns. Although wearable FM monitors could address this gap, the interpretation and standardization of wearable sensor-detected FM patterns have been severely complicated by the lack of commercial solutions and inconsistencies in sensor types, algorithmic settings, and validation protocols across different studies. This study presents a comparative analysis of in-home monitored longitudinal FM patterns concurrently captured by the three most prevalent wearable sensing modalities: accelerometer, acoustic sensor, and piezoelectric sensor. Additionally, we propose a novel algorithm to automatically separate fetal hiccups, which can confound the interpretation of FM patterns. Five pregnant women participated in this study, providing 31 hours of longitudinal in-home FM recordings between 25–38 weeks of gestation. The results demonstrated significant differences (p < 0.05) in FM patterns across sensor types for most biophysical properties, except for the incident rate (FMs/hour), suggesting that the incidence rate may serve as a relatively robust metric across sensor types. The proposed hiccup detection algorithm demonstrated strong agreement with maternally detected fetal hiccups (F1 score ranging from 0.5–0.8 across sensor types) and the resulting hiccup rates (0.1–0.19 bouts/hour across sensor types) aligned well with the established literature (0.17–0.2 bouts/hour), validating the algorithm. These findings underscore the feasibility of our wearable system for longitudinal, in-home FM monitoring and lay the groundwork for standardizing FM assessment.


  • Comparative Performance Evaluation of Fetal Movement-Detecting Wearable Sensors Using a Body-Worn Device

    by Abhishek K. Ghosh, Omar-Ibne Shahid, Niamh C. Nowlan, Ravi Vaidyanathan

    The inability of existing fetal movement (FM) detection methods, such as ultrasonography, to provide reliable in-home monitoring of FM has triggered a recent surge in efforts to design wearable sensor-based FM monitors. However, the relative performances of currently available FM-detecting wearable sensors and their possible synergies have not been quantified. To address this research gap, we present a detailed analysis of response characteristics and detection performances of the three most promising FM-detecting wearable sensors, namely the accelerometer, the acoustic sensor, and the piezoelectric diaphragm, both individually and in combination. A custom-made wearable belt with all three types of sensors was fabricated for home use. Maternal sensations of FM were contrasted to sensor output over a total of 33 hours of use with five pregnant participants. The results show that, for individual sensor types, the piezoelectric diaphragm outperformed (F 1 score = 0.71) the accelerometer (F 1 score = 0.65) and the acoustic sensor (F 1 score = 0.65) significantly (p < 0.05). The combination of multiple sensor types provided notable performance improvements underscoring the importance of heterogeneity in the sensor combination. The best overall performance was achieved from the combination of all three sensor types (F 1 score = 0.79), which was very closely followed by the combination of acoustic sensors and piezoelectric diaphragms (F 1 score = 0.78) making it an efficient choice for wearable FM monitors. We believe the findings from this research will lead to an optimum design of a wearable FM monitor.


  • Open Access

    Multi-modal detection of fetal movements using a wearable monitor

    by Abhishek K. Ghosh, Danilo S. Catelli, Samuel Wilson, Niamh C. Nowlan, Ravi Vaidyanathan


  • Open Access

    Enhancement of Pool Boiling Heat Transfer over Plain and Rough Cylindrical Tubes

    by Farhan M. Haidary, Rabbi Hasan, Mohammad Adib, Sadman H. Labib, Jubayer Hossain, Abhishek K. Ghosh, Anjan Goswami

    This study investigates the pool boiling heat transfer of water over cylindrical heating tubes for different orientations and surface roughness of the tubes. First, two orientations of a smooth heating tube, horizontal and vertical, were used in the boiling chamber. For a given heat flux, the heat transfer coefficient achieved with the horizontal tube was always higher than that for the vertical tube. To investigate the influence of surface roughness, a rough heating tube with a fully rough outer surface was developed through a metal etching process. Under the same range of wall superheat, the rough tube enhanced the heat transfer rate significantly compared to the smooth tube. Finally, a modified heating tube (MHT) was developed by axially roughening half of the surface of an originally smooth tube. The orientation angle of the rough surface of this MHT was varied from 0° (horizontal-upward) to 180° (horizontal-downward) in the chamber. The heat flux increased significantly with the increase of orientation angles from 0° to 90° (the maximum of 80 kW/m2 at 90°), whereas the same decreased as the orientation angle is further increased from 90° to 180°. Results revealed that the bubble dynamics over the heating tubes play a vital role in pool boiling performance.


  • Open Access

    A Novel Fetal Movement Simulator for the Performance Evaluation of Vibration Sensors for Wearable Fetal Movement Monitors

    by Abhishek Kumar Ghosh, Sonny F. Burniston, Daniel Krentzel, Abhishek Roy, Adil Shoaib Sheikh, Talha Siddiq, Paula Mai Phuong Trinh, Marta Mambrilla Velazquez, Hei-Ting Vielle, Niamh C. Nowlan, et al.

    Fetal movements (FM) are an important factor in the assessment of fetal health. However, there is currently no reliable way to monitor FM outside clinical environs. While extensive research has been carried out using accelerometer-based systems to monitor FM, the desired accuracy of detection is yet to be achieved. A major challenge has been the difficulty of testing and calibrating sensors at the pre-clinical stage. Little is known about fetal movement features, and clinical trials involving pregnant women can be expensive and ethically stringent. To address these issues, we introduce a novel FM simulator, which can be used to test responses of sensor arrays in a laboratory environment. The design uses a silicon-based membrane with material properties similar to that of a gravid abdomen to mimic the vibrations due to fetal kicks. The simulator incorporates mechanisms to pre-stretch the membrane and to produce kicks similar to that of a fetus. As a case study, we present results from a comparative study of an acoustic sensor, an accelerometer, and a piezoelectric diaphragm as candidate vibration sensors for a wearable FM monitor. We find that the acoustic sensor and the piezoelectric diaphragm are better equipped than the accelerometer to determine durations, intensities, and locations of kicks, as they have a significantly greater response to changes in these conditions than the accelerometer. Additionally, we demonstrate that the acoustic sensor and the piezoelectric diaphragm can detect weaker fetal movements (threshold wall displacements are less than 0.5 mm) compared to the accelerometer (threshold wall displacement is 1.5 mm) with a trade-off of higher power signal artefacts. Finally, we find that the piezoelectric diaphragm produces better signal-to-noise ratios compared to the other two sensors in most of the cases, making it a promising new candidate sensor for wearable FM monitors. We believe that the FM simulator represents a key development towards enabling the eventual translation of wearable FM monitoring garments.