Prestressed MF-FRP: Experimental Study of Rapid Retrofit Solution for Deteriorated Prestressed C-Channel Beams
- 1 February 2021
- journal article
- research article
- Published by American Society of Civil Engineers (ASCE) in Journal of Performance of Constructed Facilities
- Vol. 35 (1) , 04020124
Abstract
This paper presents design and installation details and full-scale test results for a prestressed mechanically fastened fiber-reinforced polymer (MF-FRP) retrofit solution that restores the original operating and inventory rating of prestressed concrete C-channel bridge superstructures with prestress losses due to concrete deterioration and steel corrosion. A retrofit solution that can be installed rapidly and immediately restores prestress losses is desired to minimize impacts on commerce, public transportation, and emergency services. Six 9.41-m (30-ft) long C-channel beams were tested for three-point bending to failure. The results of the experimental study indicate that the MF-FRP retrofit is capable of immediately restoring deteriorated C-channel beams with a 36% reduction in capacity from the original operating and inventory ratings. In this study, the reduction in the capacity of the C-channel beams was induced in the lab by cutting the bottom strand of each stem of the C-channel beam to simulate total prestress losses at the point of maximum internal moment. Further, the results of the experimental study indicate that the examined MF-FRP retrofit solution can be installed in 4.1 labor hours per retrofitted C-channel beam. Therefore, a four-worker DOT maintenance crew can install the retrofit on up to seven beams in a single eight-hour workday. A layered sectional analysis can be used to predict the flexural capacity of retrofitted C-channel beams with very good accuracy.Keywords
This publication has 18 references indexed in Scilit:
- Analysis and design of RC structures strengthened with mechanically fastened FRP laminates: A reviewComposites Part B: Engineering, 2013
- Experimental investigation of the mechanical connection between FRP laminates and concreteComposites Part B: Engineering, 2013
- Slip effects in reinforced concrete beams with mechanically fastened FRP stripCement and Concrete Composites, 2009
- Performance of Mechanically Fastened FRP Strengthened Concrete Beams in FlexureJournal of Composites for Construction, 2008
- Analysis of RC beams strengthened with mechanically fastened FRP (MF-FRP) stripsComposite Structures, 2007
- Strengthening of RC Continuous Beams by External PrestressingJournal of Structural Engineering, 2007
- Wood Members Strengthened with Mechanically Fastened FRP StripsJournal of Composites for Construction, 2006
- Flexural Fatigue Behavior of Reinforced Concrete Beams Strengthened with FRP Fabric and Precured Laminate SystemsJournal of Composites for Construction, 2006
- Flexural Strengthening of Reinforced Concrete Beams by Mechanically Attaching Fiber-Reinforced Polymer StripsJournal of Composites for Construction, 2004
- Externally Prestressed Members: Evaluation of Second-Order EffectsJournal of Structural Engineering, 1999