Rudolf Seracino
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Rudolf Seracino has a total of 84 co-authors. Here are the top co-authors by number of shared publications:
- Gregory Lucier
North Carolina State Univ
5 shared publications - Deric John Oehlers
School of Civil, Environmental and Mining Engineering, University of Adelaide, South Australia 5005, Australia
4 shared publications - Brad C.
Assistant Professor, Dept. of Civil and Mechanical Engineering, United States Military Academy, West Point, NY 10996. ORCID:
3 shared publications Deric J. Oehlers
Emeritus Professor of Structural Engineering, School of Civil, Environmental and Mining Engineering, Univ. of Adelaide, Adelaide, SA 5005, Australia
3 shared publicationsGregory Lucier
3 shared publicationsIrene Liu
3 shared publications
Latest Publications
- 1 January 2025
- Published by American Concrete Institute
- Vol. 365, 135-147
The Effect of Bond on the Behavior of GFRP Reinforced Deep Beams
As glass fiber-reinforced polymer (GFRP) reinforcing bars become more widely used, there is a need to better understand the behavior of GFRP reinforced members.
- 1 January 2025
- Published by American Concrete Institute
- Vol. 365, 135-147
The Effect of Bond on the Behavior of GFRP Reinforced Deep Beams
As glass fiber-reinforced polymer (GFRP) reinforcing bars become more widely used, there is a need to better understand the behavior of GFRP reinforced members.
- 1 May 2024
- Published by American Concrete Institute in ACI Structural Journal
- Vol. 121  (3) , 57-68
Impact of Confinement on Bar Anchorage in Relocated Plastic Hinges
Bridges subjected to extreme damage from earthquakes are usually
- 1 May 2024
- Published by American Concrete Institute in ACI Structural Journal
- Vol. 121  (3) , 57-68
Impact of Confinement on Bar Anchorage in Relocated Plastic Hinges
Bridges subjected to extreme damage from earthquakes are usually
- 10 August 2023
- Published by SAGE Publications in Transportation Research Record: Journal of the Transportation Research Board
- Vol. 2678  (4) , 804-818
Rapid Prestressed Concrete Retrofit with Prestressed Mechanically-Fastened Fiber-Reinforced Polymer: Field Performance and Observation for a Deteriorated Prestressed Concrete Bridge
This paper presents repairs to rural bridges in North Carolina that deteriorated as a result variously of aging, overweight traffic, and exposure to salts and sulfates. The prestressed concrete C-channel superstructures exhibited prestressing strand loss and displayed significant concrete spalling, with one structure having to be closed to traffic after a routine inspection. Analysis conducted using the American Association of State Highway and Transportations Officials (AASHTO) bridge load rating criteria concluded that repair techniques which strengthen deteriorated flexural elements without also restoring lost prestressing forces are insufficient to maintain load ratings in C-channel structures with heavily damaged prestressing tendons. A prestressed mechanically-fastened fiber-reinforced polymer (MF-FRP) retrofit solution was developed and successfully installed on three structures by the authors and North Carolina Department of Transportation maintenance crews. The most extensive of these three repairs is presented here in detail. The field applications and associated analysis show the temporary MF-FRP repair system is capable of restoring lost prestressing forces, allowing original inventory and operating ratings to remain in place until a permanent superstructure replacement can be scheduled. The most heavily repaired bridge remains in service after 23 months, its performance demonstrated by long-term monitoring data. As currently implemented, the MF-FRP repair is a viable temporary solution for maintaining traffic on a degraded structure while a replacement structure is designed, programmed, and implemented. Efforts to expand the MF-FRP repair into a longer-term solution are underway.
- 10 August 2023
- Published by SAGE Publications in Transportation Research Record: Journal of the Transportation Research Board
- Vol. 2678  (4) , 804-818
Rapid Prestressed Concrete Retrofit with Prestressed Mechanically-Fastened Fiber-Reinforced Polymer: Field Performance and Observation for a Deteriorated Prestressed Concrete Bridge
This paper presents repairs to rural bridges in North Carolina that deteriorated as a result variously of aging, overweight traffic, and exposure to salts and sulfates. The prestressed concrete C-channel superstructures exhibited prestressing strand loss and displayed significant concrete spalling, with one structure having to be closed to traffic after a routine inspection. Analysis conducted using the American Association of State Highway and Transportations Officials (AASHTO) bridge load rating criteria concluded that repair techniques which strengthen deteriorated flexural elements without also restoring lost prestressing forces are insufficient to maintain load ratings in C-channel structures with heavily damaged prestressing tendons. A prestressed mechanically-fastened fiber-reinforced polymer (MF-FRP) retrofit solution was developed and successfully installed on three structures by the authors and North Carolina Department of Transportation maintenance crews. The most extensive of these three repairs is presented here in detail. The field applications and associated analysis show the temporary MF-FRP repair system is capable of restoring lost prestressing forces, allowing original inventory and operating ratings to remain in place until a permanent superstructure replacement can be scheduled. The most heavily repaired bridge remains in service after 23 months, its performance demonstrated by long-term monitoring data. As currently implemented, the MF-FRP repair is a viable temporary solution for maintaining traffic on a degraded structure while a replacement structure is designed, programmed, and implemented. Efforts to expand the MF-FRP repair into a longer-term solution are underway.
- 21 June 2023
- Published by Elsevier in Construction and Building Materials
- Vol. 394
Behavior of large diameter carbon fiber anchors
- 21 June 2023
- Published by Elsevier in Construction and Building Materials
- Vol. 394
Behavior of large diameter carbon fiber anchors
- 27 November 2021
- Published by Springer Nature
- p. 1199-1207
Tensile Behavior of Large Diameter Carbon Fiber Anchors
- 27 November 2021
- Published by Springer Nature
- p. 1199-1207
Tensile Behavior of Large Diameter Carbon Fiber Anchors
- 27 November 2021
- Published by Springer Nature
- p. 1208-1215
Determination of a Large-Diameter Carbon Fiber Anchor Capacity
- 27 November 2021
- Published by Springer Nature
- p. 1208-1215
Determination of a Large-Diameter Carbon Fiber Anchor Capacity
- 1 February 2021
- Published by American Society of Civil Engineers (ASCE) in Journal of Performance of Constructed Facilities
- Vol. 35  (1) , 04020124
Prestressed MF-FRP: Experimental Study of Rapid Retrofit Solution for Deteriorated Prestressed C-Channel Beams
This paper presents design and installation details and full-scale test results for a prestressed mechanically fastened fiber-reinforced polymer (MF-FRP) retrofit solution that restores the original operating and inventory rating of prestressed concrete C-channel bridge superstructures with prestress losses due to concrete deterioration and steel corrosion. A retrofit solution that can be installed rapidly and immediately restores prestress losses is desired to minimize impacts on commerce, public transportation, and emergency services. Six 9.41-m (30-ft) long C-channel beams were tested for three-point bending to failure. The results of the experimental study indicate that the MF-FRP retrofit is capable of immediately restoring deteriorated C-channel beams with a 36% reduction in capacity from the original operating and inventory ratings. In this study, the reduction in the capacity of the C-channel beams was induced in the lab by cutting the bottom strand of each stem of the C-channel beam to simulate total prestress losses at the point of maximum internal moment. Further, the results of the experimental study indicate that the examined MF-FRP retrofit solution can be installed in 4.1 labor hours per retrofitted C-channel beam. Therefore, a four-worker DOT maintenance crew can install the retrofit on up to seven beams in a single eight-hour workday. A layered sectional analysis can be used to predict the flexural capacity of retrofitted C-channel beams with very good accuracy.
- 1 February 2021
- Published by American Society of Civil Engineers (ASCE) in Journal of Performance of Constructed Facilities
- Vol. 35  (1) , 04020124
Prestressed MF-FRP: Experimental Study of Rapid Retrofit Solution for Deteriorated Prestressed C-Channel Beams
This paper presents design and installation details and full-scale test results for a prestressed mechanically fastened fiber-reinforced polymer (MF-FRP) retrofit solution that restores the original operating and inventory rating of prestressed concrete C-channel bridge superstructures with prestress losses due to concrete deterioration and steel corrosion. A retrofit solution that can be installed rapidly and immediately restores prestress losses is desired to minimize impacts on commerce, public transportation, and emergency services. Six 9.41-m (30-ft) long C-channel beams were tested for three-point bending to failure. The results of the experimental study indicate that the MF-FRP retrofit is capable of immediately restoring deteriorated C-channel beams with a 36% reduction in capacity from the original operating and inventory ratings. In this study, the reduction in the capacity of the C-channel beams was induced in the lab by cutting the bottom strand of each stem of the C-channel beam to simulate total prestress losses at the point of maximum internal moment. Further, the results of the experimental study indicate that the examined MF-FRP retrofit solution can be installed in 4.1 labor hours per retrofitted C-channel beam. Therefore, a four-worker DOT maintenance crew can install the retrofit on up to seven beams in a single eight-hour workday. A layered sectional analysis can be used to predict the flexural capacity of retrofitted C-channel beams with very good accuracy.
- 1 October 2019
- Published by Elsevier in Cement and Concrete Composites
- Vol. 103, 263-278
Numerical simulation and experimental corroboration of galvanic corrosion of mild steel in synthetic concrete pore solution
- 1 October 2019
- Published by Elsevier in Cement and Concrete Composites
- Vol. 103, 263-278
Numerical simulation and experimental corroboration of galvanic corrosion of mild steel in synthetic concrete pore solution
- 1 August 2019
- Published by American Society of Civil Engineers (ASCE) in Journal of Composites for Construction
- Vol. 23  (4)
Anchor Bolt Patterns for Mechanically Fastened FRP Plates
This paper examines the results of material testing of hybrid carbon and glass fiber-reinforced polymer (FRP) plates for use in prestressed mechanically fastened applications. The small-scale material tests were conducted in three phases: (1) uniaxial tension without holes, (2) uniaxial tension with open holes, and (3) uniaxial tension with single- and multibolt connections. In all three phases of testing, Digital Image Correlation (DIC) was used to obtain continuous strain data, showing holistic strain field development through failure. A total of 89 tests were conducted across 17 treatment groups to develop an anchor pattern and fastener spacing which is optimized with respect to maximum capacity and behavior under anticipated service load conditions. The tests presented comprise the initial phase of a larger project that aims to employ prestressed mechanically fastened FRP (MF-FRP) plates as a retrofit repair solution for deteriorated prestressed concrete bridge superstructures. Results conclude that 2 lines of 11 bolts with diameters of 12.7 mm, with longitudinal spacing of 100 mm and transverse spacing of 38 mm, provide an end-region anchor pattern with an ultimate capacity of 206 kN which is 89% of the ultimate capacity for the examined FRP plate with holes.
- 1 August 2019
- Published by American Society of Civil Engineers (ASCE) in Journal of Composites for Construction
- Vol. 23  (4)
Anchor Bolt Patterns for Mechanically Fastened FRP Plates
This paper examines the results of material testing of hybrid carbon and glass fiber-reinforced polymer (FRP) plates for use in prestressed mechanically fastened applications. The small-scale material tests were conducted in three phases: (1) uniaxial tension without holes, (2) uniaxial tension with open holes, and (3) uniaxial tension with single- and multibolt connections. In all three phases of testing, Digital Image Correlation (DIC) was used to obtain continuous strain data, showing holistic strain field development through failure. A total of 89 tests were conducted across 17 treatment groups to develop an anchor pattern and fastener spacing which is optimized with respect to maximum capacity and behavior under anticipated service load conditions. The tests presented comprise the initial phase of a larger project that aims to employ prestressed mechanically fastened FRP (MF-FRP) plates as a retrofit repair solution for deteriorated prestressed concrete bridge superstructures. Results conclude that 2 lines of 11 bolts with diameters of 12.7 mm, with longitudinal spacing of 100 mm and transverse spacing of 38 mm, provide an end-region anchor pattern with an ultimate capacity of 206 kN which is 89% of the ultimate capacity for the examined FRP plate with holes.