A Comparison of Reflectance Pulse Oximetry and near Infrared Spectroscopy for the Determination of the Fraction of Oxygenated Haemoglobin at Low Oxygen Saturations in an Animal Study
- 1 October 2006
- journal article
- Published by SAGE Publications in Journal of Near Infrared Spectroscopy
- Vol. 14 (5) , 307-315
Abstract
Near infrared spectroscopy scans of cerebral tissue in vivo were compared to reflectance pulse oximetry of local tissue by comparing each method to in vitro femoral arterial blood measurements in an experimental study on 16 newborn piglets. To test the accuracy, the 16 piglets were desaturated stepwise during general anaesthesia, leading to the following results of linear regression analysis of complete data, linear regression analysis for individual piglets and bias ± precision (1SD). Local oxygen saturation (reflectance pulse oximetry) versus arterial (haemoximeter): linear regression analysis R2 = 0.92, n = 207, linear regression analysis for individual piglets: R2 = 0.95 ± 0.05*, p < 0.05 versus near infrared spectroscopy, bias ± precision (1SD): 0.15 ± 9.65%; cerebral tissue oxygenation index (near infrared spectroscopy) versus arterial (haemoximeter): linear regression analysis R2 = 0.26, n = 161, linear regression analysis for individuals R2 = 0.83 ± 0.15, bias ± precision (1SD) −3.33 ± 29%; cerebral concentration of delta oxygenated haemoglobin (near infrared spectroscopy, NIRO 300) versus the corresponding arterial parameter (haemoximeter): linear regression analysis R2 = 0.76, n = 189, linear regression analysis for individuals R2 = 0.90 ± 0.06, bias ± precision (1SD) −2.54 ± 3 μM cm−3. The results of reflectance pulse oximetry in local tissue correlated more closely to in vitro femoral arterial blood measurements (haemoximeter) than results of near infrared spectroscopy, in vivo.Keywords
This publication has 13 references indexed in Scilit:
- Inhaled nitric oxide induces cerebrovascular effects in anesthetized pigsNeuroscience Letters, 2003
- A comparison of cerebral oxygenation as measured by the NIRO 300 and the INVOS 5100 Near‐Infrared SpectrophotometersAnaesthesia, 2002
- Measurement of absolute values of hemoglobin oxygenation in the brain of small rodents by near infrared reflection spectrophotometryJournal of Neuroscience Methods, 2002
- Evaluation of a Near-Infrared Spectrometer (NIRO 300) for the Detection of Intracranial Oxygenation Changes in the Adult HeadStroke, 2001
- Non-invasive and quantitative near-infrared haemoglobin spectrometry in the piglet brain during hypoxic stress, using a frequency-domain multidistance instrument†Physics in Medicine & Biology, 2000
- Non-invasive optical mapping of the piglet brain in real timeOptics Express, 1999
- Noninvasive Measurement of Regional Cerebral Blood Flow by Near-Infrared Spectroscopy and Indocyanine GreenJournal of Cerebral Blood Flow & Metabolism, 1998
- Arterial oxygen saturation in relation to metabolic acidosis in fetal lambsAmerican Journal of Obstetrics and Gynecology, 1995
- Reflectance pulse oximetry (RPOX): Two sensors compared in pigletsAmerican Journal of Obstetrics and Gynecology, 1995
- Reflectance Pulse Oximetry in Fetal LambsPediatric Research, 1992