Latest Publications
- 24 April 2019
- Published by Springer Nature
- p. 1683-1691
Anästhesie bei Patienten mit allergischer Diathese
- 24 April 2019
- Published by Springer Nature
- p. 1683-1691
Anästhesie bei Patienten mit allergischer Diathese
- 1 January 2016
- Published by Springer Nature
- p. 1-9
Anästhesie bei Patienten mit allergischer Diathese
- 25 October 2008
- Published by Springer Nature in Journal of Clinical Monitoring and Computing
- Vol. 22 (5) , 375-380
The Initial Tangent of the Aortic Pressure Increase is an Estimate of Left Ventricular Contractility in Pigs
The aim was, to identify an estimate of left ventricular contractility derived from the aortic pressure wave without load changing manoeuvres. For this purpose, left ventricular contractility was assessed with several aortic pressure wave form derived parameters and was compared to standard parameters of left ventricular contractility (conductance technique) in an experimental study. Measurements were taken during baseline, after β-stimulation and after injection of a β-antagonist. The initial and the secondary tangent, the area under the aortic pressure, and the stroke volume were correlated with the endsystolic elastance, a mainly load independent measure of left ventricular contractility: The initial tangent of the aortic pressure increase correlated significantly with the endsystolic elastance (r = 0.54, P < 0.05). The initial tangent of the aortic pressure increase was significantly increased from baseline at β-stimulation (from 20.2 ± 4.7 to 36.4 ± 6.8 mmHg s−1, P < 0.05) and decreased after injection of a β-antagonist (from 20.2 ± 4.7 to 12.3 ± 2.0, P < 0.05). Thus, we conclude that the initial tangent of the aortic pressure increase is a valid estimate of left ventricular contractility in piglets.
- 25 October 2008
- Published by Springer Nature in Journal of Clinical Monitoring and Computing
- Vol. 22 (5) , 375-380
The Initial Tangent of the Aortic Pressure Increase is an Estimate of Left Ventricular Contractility in Pigs
The aim was, to identify an estimate of left ventricular contractility derived from the aortic pressure wave without load changing manoeuvres. For this purpose, left ventricular contractility was assessed with several aortic pressure wave form derived parameters and was compared to standard parameters of left ventricular contractility (conductance technique) in an experimental study. Measurements were taken during baseline, after β-stimulation and after injection of a β-antagonist. The initial and the secondary tangent, the area under the aortic pressure, and the stroke volume were correlated with the endsystolic elastance, a mainly load independent measure of left ventricular contractility: The initial tangent of the aortic pressure increase correlated significantly with the endsystolic elastance (r = 0.54, P < 0.05). The initial tangent of the aortic pressure increase was significantly increased from baseline at β-stimulation (from 20.2 ± 4.7 to 36.4 ± 6.8 mmHg s−1, P < 0.05) and decreased after injection of a β-antagonist (from 20.2 ± 4.7 to 12.3 ± 2.0, P < 0.05). Thus, we conclude that the initial tangent of the aortic pressure increase is a valid estimate of left ventricular contractility in piglets.
- 1 October 2006
- Published by SAGE Publications in Journal of Near Infrared Spectroscopy
- Vol. 14 (5) , 307-315
A Comparison of Reflectance Pulse Oximetry and near Infrared Spectroscopy for the Determination of the Fraction of Oxygenated Haemoglobin at Low Oxygen Saturations in an Animal Study
Near infrared spectroscopy scans of cerebral tissue in vivo were compared to reflectance pulse oximetry of local tissue by comparing each method to in vitro femoral arterial blood measurements in an experimental study on 16 newborn piglets. To test the accuracy, the 16 piglets were desaturated stepwise during general anaesthesia, leading to the following results of linear regression analysis of complete data, linear regression analysis for individual piglets and bias ± precision (1SD). Local oxygen saturation (reflectance pulse oximetry) versus arterial (haemoximeter): linear regression analysis R2 = 0.92, n = 207, linear regression analysis for individual piglets: R2 = 0.95 ± 0.05*, p < 0.05 versus near infrared spectroscopy, bias ± precision (1SD): 0.15 ± 9.65%; cerebral tissue oxygenation index (near infrared spectroscopy) versus arterial (haemoximeter): linear regression analysis R2 = 0.26, n = 161, linear regression analysis for individuals R2 = 0.83 ± 0.15, bias ± precision (1SD) −3.33 ± 29%; cerebral concentration of delta oxygenated haemoglobin (near infrared spectroscopy, NIRO 300) versus the corresponding arterial parameter (haemoximeter): linear regression analysis R2 = 0.76, n = 189, linear regression analysis for individuals R2 = 0.90 ± 0.06, bias ± precision (1SD) −2.54 ± 3 μM cm−3. The results of reflectance pulse oximetry in local tissue correlated more closely to in vitro femoral arterial blood measurements (haemoximeter) than results of near infrared spectroscopy, in vivo.
- 1 October 2006
- Published by SAGE Publications in Journal of Near Infrared Spectroscopy
- Vol. 14 (5) , 307-315
A Comparison of Reflectance Pulse Oximetry and near Infrared Spectroscopy for the Determination of the Fraction of Oxygenated Haemoglobin at Low Oxygen Saturations in an Animal Study
Near infrared spectroscopy scans of cerebral tissue in vivo were compared to reflectance pulse oximetry of local tissue by comparing each method to in vitro femoral arterial blood measurements in an experimental study on 16 newborn piglets. To test the accuracy, the 16 piglets were desaturated stepwise during general anaesthesia, leading to the following results of linear regression analysis of complete data, linear regression analysis for individual piglets and bias ± precision (1SD). Local oxygen saturation (reflectance pulse oximetry) versus arterial (haemoximeter): linear regression analysis R2 = 0.92, n = 207, linear regression analysis for individual piglets: R2 = 0.95 ± 0.05*, p < 0.05 versus near infrared spectroscopy, bias ± precision (1SD): 0.15 ± 9.65%; cerebral tissue oxygenation index (near infrared spectroscopy) versus arterial (haemoximeter): linear regression analysis R2 = 0.26, n = 161, linear regression analysis for individuals R2 = 0.83 ± 0.15, bias ± precision (1SD) −3.33 ± 29%; cerebral concentration of delta oxygenated haemoglobin (near infrared spectroscopy, NIRO 300) versus the corresponding arterial parameter (haemoximeter): linear regression analysis R2 = 0.76, n = 189, linear regression analysis for individuals R2 = 0.90 ± 0.06, bias ± precision (1SD) −2.54 ± 3 μM cm−3. The results of reflectance pulse oximetry in local tissue correlated more closely to in vitro femoral arterial blood measurements (haemoximeter) than results of near infrared spectroscopy, in vivo.
- 1 July 2005
- Published by Elsevier in European Journal of Pharmacology
- Vol. 517 (3) , 208-216
Effect of prostaglandin I2 analogues on left ventricular diastolic function in vivo
- 1 July 2005
- Published by Elsevier in European Journal of Pharmacology
- Vol. 517 (3) , 208-216
Effect of prostaglandin I2 analogues on left ventricular diastolic function in vivo
- 1 August 2004
- Vol. 54 (4) , 404-9
Mycoplasma haemocanis infection--a kennel disease?
Mycoplasma haemocanis (formerly Haemobartonella canis) is a red blood cell parasite that causes disease mainly in immunosuppressed and splenectomized dogs. Clinical outbreak of the disease resulted in failure of a large experimental project. We aimed to identify whether M. haemocanis has increased prevalence in kennel-raised dogs. In a prospective study, we compared the prevalence of M. haemocanis in whole blood (anti-coagulated by use of EDTA) collected from pet dogs (University of Illinois, Urbana Champaign, Ill.; n = 60) with that in blood from dogs raised in three distinct kennels in western Europe (WE; n = 23), eastern Europe (EE; n = 20), and North America (NA; n = 20). Screening included antibody testing and microscopy of blood smears. The presence of M. haemocanis was identified using a polymerase chain reaction (PCR) assay for specific DNA of the organism. None of the pet dogs (0%) was test positive for M. haemocanis DNA. Mycoplasma haemocanis was found in dogs tested at all of the kennels. Infection rate in the three kennels was 30, 35, and 87%, respectively (all P < 0.001 versus control, chi2-test). Latent infection with M. haemocanis was not a single observation in kennel-raised dogs. Prevalence may be higher than that in a pet dog population. The potential exists for these latent infections to adversely affect or confound research results.
- 1 August 2004
- Vol. 54 (4) , 404-9
Mycoplasma haemocanis infection--a kennel disease?
Mycoplasma haemocanis (formerly Haemobartonella canis) is a red blood cell parasite that causes disease mainly in immunosuppressed and splenectomized dogs. Clinical outbreak of the disease resulted in failure of a large experimental project. We aimed to identify whether M. haemocanis has increased prevalence in kennel-raised dogs. In a prospective study, we compared the prevalence of M. haemocanis in whole blood (anti-coagulated by use of EDTA) collected from pet dogs (University of Illinois, Urbana Champaign, Ill.; n = 60) with that in blood from dogs raised in three distinct kennels in western Europe (WE; n = 23), eastern Europe (EE; n = 20), and North America (NA; n = 20). Screening included antibody testing and microscopy of blood smears. The presence of M. haemocanis was identified using a polymerase chain reaction (PCR) assay for specific DNA of the organism. None of the pet dogs (0%) was test positive for M. haemocanis DNA. Mycoplasma haemocanis was found in dogs tested at all of the kennels. Infection rate in the three kennels was 30, 35, and 87%, respectively (all P < 0.001 versus control, chi2-test). Latent infection with M. haemocanis was not a single observation in kennel-raised dogs. Prevalence may be higher than that in a pet dog population. The potential exists for these latent infections to adversely affect or confound research results.
- 1 January 2004
- Published by Taylor & Francis in Experimental Lung Research
- Vol. 30 (7) , 635-651
AEROSOL DELIVERY DURING MECHANICAL VENTILATION TO THE RAT
The authors have adjusted a jet nebulizer to a mechanical ventilator (Servo Ventilator, Siemens) to deliver an aerosol to rats. They aimed to clarify whether a modified jet nebulizer generating particles with a mass median aerodynamic diameter of 2 microm would be effective and safe in intubated ventilated rats. Fluorescent microspheres (diameter: 1.0 microm) were aerosolized to verify qualitatively and quantitatively intrapulmonary deposition. Particle deposition fraction was 3.8% (1.3%) of the delivered dose (median [interquartile range]). There was no evidence for any adverse event as assessed from heart rate, mean arterial pressure, PaO2 and PaCO2 before, during, and after nebulization. No pulmonary tissue trauma was detected histologically.
- 1 January 2004
- Published by Taylor & Francis in Experimental Lung Research
- Vol. 30 (7) , 635-651
AEROSOL DELIVERY DURING MECHANICAL VENTILATION TO THE RAT
The authors have adjusted a jet nebulizer to a mechanical ventilator (Servo Ventilator, Siemens) to deliver an aerosol to rats. They aimed to clarify whether a modified jet nebulizer generating particles with a mass median aerodynamic diameter of 2 microm would be effective and safe in intubated ventilated rats. Fluorescent microspheres (diameter: 1.0 microm) were aerosolized to verify qualitatively and quantitatively intrapulmonary deposition. Particle deposition fraction was 3.8% (1.3%) of the delivered dose (median [interquartile range]). There was no evidence for any adverse event as assessed from heart rate, mean arterial pressure, PaO2 and PaCO2 before, during, and after nebulization. No pulmonary tissue trauma was detected histologically.