3D prompt gamma imaging for proton beam range verification
- 30 January 2018
- journal article
- research article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 63 (3) , 035019
Abstract
We tested the ability of a single Compton camera (CC) to produce 3-dimensional (3D) images of prompt gammas (PGs) emitted during the irradiation of a tissue-equivalent plastic phantom with proton pencil beams for clinical doses delivered at clinical dose rates. PG measurements were made with a small prototype CC placed at three different locations along the proton beam path. We evaluated the ability of the CC to produce images at each location for two clinical scenarios: (1) the delivery of a single 2 Gy pencil beam from a hypo-fractionated treatment (~9 × 10 8 protons), and (2) a single pencil beam from a standard treatment (~1 × 10 8 protons). Additionally, the data measured at each location were combined to simulate measurements with a larger scale, clinical CC and its ability to image shifts in the Bragg peak (BP) range for both clinical scenarios. With our prototype CC, the location of the distal end of the BP could be seen with the CC placed up to 4 cm proximal or distal to the BP distal falloff. Using the data from the simulated full scale clinical CC, 3D images of the PG emission were produced with the delivery of as few as 1 × 10 8 protons, and shifts in the proton beam range as small as 2 mm could be detected for delivery of a 2 Gy spot. From these results we conclude that 3D PG imaging for proton range verification under clinical beam delivery conditions is possible with a single CC.Keywords
Funding Information
- Instituto Nacional de Cancerología (R01CA187416)
This publication has 45 references indexed in Scilit:
- Evaluation of a stochastic reconstruction algorithm for use in Compton camera imaging and beam range verification from secondary gamma emission during proton therapyPhysics in Medicine & Biology, 2012
- Range uncertainties in proton therapy and the role of Monte Carlo simulationsPhysics in Medicine & Biology, 2012
- Prompt gamma detection for range verification in proton therapyCurrent Applied Physics, 2012
- Gamma electron vertex imaging and application to beam range verification in proton therapyMedical Physics, 2012
- Material efficiency studies for a Compton camera designed to measure characteristic prompt gamma rays emitted during proton beam radiotherapyPhysics in Medicine & Biology, 2011
- Optimizing a three-stage Compton camera for measuring prompt gamma rays emitted during proton radiotherapyPhysics in Medicine & Biology, 2010
- Design Guidelines for a Double Scattering Compton Camera for Prompt-$\gamma$ Imaging During Ion Beam Therapy: A Monte Carlo Simulation StudyIEEE Transactions on Nuclear Science, 2010
- Prompt gamma-ray emission from biological tissues during proton irradiation: a preliminary studyPhysics in Medicine & Biology, 2009
- Stability and characteristics of large CZT coplanar electrode detectorsIEEE Transactions on Nuclear Science, 2001
- Monte Carlo calculation of point-spread functions of Compton scatter camerasIEEE Transactions on Nuclear Science, 1997