JPJerimy C. Polf

Jerimy C. Polf

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Jerimy C. Polf has a total of 23 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Honoring Miral Dizdaroglu: the dizdar, a lesion-resolved unit for quantifying radiation-induced DNA damage

    by Joseph W. F. Robertson, Michael Zwolak, Michael Lamontagne, Tadas Penkauskas, Ronald E. Tosh, Paul Patrone, Jerimy C. Polf, Ileana M. Pazos

    From the earliest discoveries of X-rays and radioactivity, physicists and chemists immediately targeted medical applications, sometimes within months of a scientific discovery. Pioneers such as Pie...

  • 3D prompt gamma imaging for proton beam range verification

    by E Draeger, D Mackin, S Peterson, H Chen, S Avery, S Beddar, J C Polf

    We tested the ability of a single Compton camera (CC) to produce 3-dimensional (3D) images of prompt gammas (PGs) emitted during the irradiation of a tissue-equivalent plastic phantom with proton pencil beams for clinical doses delivered at clinical dose rates. PG measurements were made with a small prototype CC placed at three different locations along the proton beam path. We evaluated the ability of the CC to produce images at each location for two clinical scenarios: (1) the delivery of a single 2 Gy pencil beam from a hypo-fractionated treatment (~9 × 10 8 protons), and (2) a single pencil beam from a standard treatment (~1 × 10 8 protons). Additionally, the data measured at each location were combined to simulate measurements with a larger scale, clinical CC and its ability to image shifts in the Bragg peak (BP) range for both clinical scenarios. With our prototype CC, the location of the distal end of the BP could be seen with the CC placed up to 4 cm proximal or distal to the BP distal falloff. Using the data from the simulated full scale clinical CC, 3D images of the PG emission were produced with the delivery of as few as 1 × 10 8 protons, and shifts in the proton beam range as small as 2 mm could be detected for delivery of a 2 Gy spot. From these results we conclude that 3D PG imaging for proton range verification under clinical beam delivery conditions is possible with a single CC.


  • Feasibility Studies of a New Event Selection Method to Improve Spatial Resolution of Compton Imaging for Medical Applications

    by Emily Draeger, Steve Peterson, Dennis Mackin, Haijian Chen, Sam Beddar, Jerimy C. Polf

    A Compton imaging method for medical applications that includes new energy determination and data filtering techniques has been tested using several point sources with known emission lines. Using a prototype Compton camera, a distance-of-closest approach technique has been employed to determine the initial energy of the incoming ys and to ensure the reconstructed source position is within an acceptable distance from the known y source location. Further analysis is done by implementing a Compton line filtering technique, keeping only those interactions whose deposited energy in the first interaction matches the theoretical energy deposition predicted by the Compton equation. Using this new event filtering method, we see improvements in the full width at half maximum in the lateral profiles of y point sources of up to 70% over standard Compton imaging methods, as well as achievable spatial resolutions in the reconstructed images of better than 2 mm. In addition, this new Compton imaging method was able to reconstruct an extended source of y rays emitted during irradiation of a water tank with a clinical proton radiotherapy beam.


  • Reply to Comment on ‘Imaging of prompt gamma rays emitted during delivery of clinical proton beams with a Compton camera: feasibility studies for range verification’

    by Jerimy C Polf, Stephen Avery, Dennis S Mackin, Sam Beddar

    A reply is provided to the points raised in the comment by Dr Sitek (2016 Phys. Med. Biol. 61 8941) on Polf et al (2015 Phys. Med. Biol. 60 7085).

  • Open Access

    Anteriorly Oriented Beam Arrangements with Daily in Vivo Range Verification for Proton Therapy of Prostate Cancer: Rectal Toxicity Rates

    by Jerimy C. Polf, Michael Chuong, Bin Zhang, Minesh Mehta

    Purpose: To model whether in vivo range verification could reduce high-grade rectal toxicity for patients with prostate cancer treated with pencil beam scanning proton therapy by allowing novel proton beam arrangements compared to standard lateral opposed beams. Materials and Methods: Proton plans were generated for 8 patients with prostate cancer previously treated with photons by volumetric-modulated arc therapy (VMAT). The VMAT plans were generated by using a uniform 6-mm planning target volume (PTV) expansion. For the proton plans an additional distal margin (3.5% of beam range) was added to the uniform 6-mm PTV to account for range uncertainty, using 3 beam arrangements: (1) lateral opposed beams (LAT), (2) left and right anterior oblique beams (LAO/RAO), and (3) a single anterior-posterior beam (AP). Assuming use of in vivo range verification, plans were generated by using a reduced distal PTV and distal range uncertainty expansion (2 mm each) with AP (AP–2 mm) and LAO/RAO (LAO/RAO–2 mm) be...


  • Detecting prompt gamma emission during proton therapy: the effects of detector size and distance from the patient

    by Jerimy C Polf, Dennis Mackin, Eunsin Lee, Stephen Avery, Sam Beddar

    Recent studies have suggested that the characteristics of prompt gammas (PGs) emitted from excited nuclei during proton therapy are advantageous for determining beam range during treatment delivery. Since PGs are only emitted while the beam is on, the feasibility of using PGs for online treatment verification depends greatly on the design of highly efficient detectors. The purpose of this work is to characterize how PG detection changes as a function of distance from the patient as a means of guiding the design and usage of clinical PG imaging detectors. Using a Monte Carlo model (GEANT4.9.4) we studied the detection rate (PGs per incident proton) of a high purity germanium detector for both the total PG emission and the characteristic 6.13 MeV PG emission from (16)O emitted during proton irradiation. The PG detection rate was calculated as a function of distance from the isocenter of the proton treatment nozzle for: (1) a water phantom irradiated with a proton pencil beam and (2) a prostate patient irradiated with a scanning beam proton therapy treatment field (lateral field size: ∼6 cm × 6 cm, beam range: 23.5 cm). An analytical expression of the PG detection rate as a function of distance from isocenter, detector size, and proton beam energy was then developed. The detection rates were found to be 1.3 × 10(-6) for oxygen and 3.9 × 10(-4) for the total PG emission, respectively, with the detector placed 11 cm from isocenter for a 40 MeV pencil beam irradiating a water phantom. The total PG detection rate increased by ∼85 ± 3% for beam energies greater than 150 MeV. The detection rate was found to be approximately 2.1 × 10(-6) and 1.7 × 10(-3) for oxygen and total PG emission, respectively, during delivery of a single pencil beam during a scanning beam treatment for prostate cancer. The PG detection rate as a function of distance from isocenter during irradiation of a water phantom with a single proton pencil beam was described well by the model of a point source irradiating a cylindrical detector of a known diameter over the range of beam energies commonly used for proton therapy. For the patient studies, it was necessary to divide the point source equation by an exponential factor in order to correctly predict the falloff of the PG detection rate as a function of distance from isocenter.