The Efficacy of Upper Arm Placement of Peripherally Inserted Central Catheters Using Bedside Ultrasound and Microintroducer Technique
Authors:
- 1 May 2008
- journal article
- research article
- Published by Wolters Kluwer Health in Journal of Infusion Nursing
- Vol. 31 (3) , 165-176
Abstract
In one hospital in southern Georgia, the review and analysis of 500 peripherally inserted central catheter procedural attempts by designated, specialty nurses using microintroducer technique and ultrasound guidance revealed an overall catheter placement success rate of 94.6%. This research analysis also provided information on the disposition of those 6-French dual-lumen and triple-lumen, power-injectable peripherally inserted central catheters actually placed in situ on subjects who remained hospitalized or within the hospital's rehabilitation facility. Of the 422 catheters removed, none exhibited signs or symptoms of mechanical phlebitis, and one tested positive per laboratory analysis for organisms confirming infection.Keywords
This publication has 23 references indexed in Scilit:
- Cost Containment and Infusion ServicesJournal of Infusion Nursing, 2005
- Cost Losses Associated With the “PICC, Stick, and Run Team” ConceptJournal of Infusion Nursing, 2005
- Guest EditorialJournal of the Association for Vascular Access, 2003
- Evaluating New Technology to Improve Patient OutcomesJournal of Infusion Nursing, 2002
- Nurse-driven Interventional TechnologyJournal of Infusion Nursing, 2001
- Peripherally Inserted Central CathetersSeminars in Interventional Radiology, 1998
- Sonographically guided placement of peripherally inserted central venous catheters: review of 355 procedures.American Journal of Roentgenology, 1998
- Bedside placement of peripherally inserted central catheters: a cost-effectiveness analysis.Radiology, 1998
- Peripherally Inserted Central Catheters in General MedicineMayo Clinic Proceedings, 1997
- Peripherally inserted central venous catheters: US-guided vascular access in pediatric patients.Radiology, 1995